Calibration of a Radiation Detector: Chromosome Dosimetry for Neutrons

  • Chapter
Probability and Bayesian Statistics

Abstract

Calibrative densities for the unknown neutron dose Df of an individual accidentally exposed to high doses (>20 rad) of neutrons are derived. These densities incorporate prior dose information (e.g., from a dosimeter reading, or from dose reconstruction efforts), information from an in vitro calibration experiment with neutrons of the same energy, and information from the number of dicentric chromosome aberrations yf observed shortly (< 4 weeks) after exposure in a sample of nf lymphocytes from the exposed individual. If Y, the number of dicentric aberrations induced by a known neutron dose d in n lymphocytes is assumed to be Poisson distributed (Y ~ Po(nαd)) and if Df and the parameter α are assumed to have gamma priors it is possible to give an analytic solution for the calibrative density f(df|D). D consists of the calibration data and the observed aberrations in a sample of lymphocytes from the exposed individual. This density characterizes the remaining uncertainty about Df after consideration of the prior information about Df and α and of the data D.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Aitchison. J., and Dunsmore, I.R., Statistical Prediction Analysis, Cambridge University Press, Cambridge (1975).

    Book  MATH  Google Scholar 

  2. Edwards, A.A., Lloyd, D.C., and Purrot, R.J., 1979, “Radiation induced chromosome aberrations and the Poisson distribution,” Rod. and Environ. Biophys., 16:80.

    Google Scholar 

  3. Bender, M.A., Preston, R.J., Leonard, R.C., and Shelby, M.D.,1986, Chromosomal aberration analysis in peripheral lymphocytes of a large control population, unpublished manuscript, Brookhaven National Laboratory, Upton, New York.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Plenum Press, New York

About this chapter

Cite this chapter

Groer, P.G., De Pereira, C.A.B. (1987). Calibration of a Radiation Detector: Chromosome Dosimetry for Neutrons. In: Viertl, R. (eds) Probability and Bayesian Statistics. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-1885-9_23

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-1885-9_23

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4612-9050-6

  • Online ISBN: 978-1-4613-1885-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics