Laser Balloon Angioplasty: Experimental In-Vivo and In-Vitro Studies

  • J. Richard Spears
  • I. Nigel Sinclair
  • Ronald D. Jenkins
Part of the Developments in Cardiovascular Medicine book series (DICM, volume 103)

Abstract

Important causes of suboptimal angiographic results following percutaneous transluminal coronary angioplasty (PTCA) include elastic recoil, arterial dissection, and the presence of thrombus. Although increased vasomotor tone may contribute to a reduction of luminal diameter improvement, passive recoil probably accounts for most of the latter. Typically, in most clinical series [1–4] a mean residual diameter of acute stenosis of approximately 30%, which roughly corresponds to a 50% luminal cross-sectional area stenosis, is found after successful PTCA, presumably as a result of such recoil. Intimal tears may further compromise an apparently successful PTCA procedure, even without propagation of a dissection, by local disruption of laminar flow patterns. When thrombus is associated with a lesion treated with PTCA, a poor result is frequently encountered, perhaps as a result of the difficulty in attempting to remodel this tissue with pressure and the possibility that spreading the thrombus along the luminal surface may increase the number of sites of potential propagation of the thrombus.

Keywords

Arterial Wall Balloon Angioplasty Luminal Diameter Tissue Temperature Laser Exposure 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Gruentzig AR, Schlumpf M, Siegenthaler W (1984). Long-term results after coronary angioplasty (abstr). Circulation 70 (Suppl 11): 11–323.Google Scholar
  2. 2.
    Cowley MJ, Vetrovec GW, Wolfgang TC (1984). Emergency coronary bypass surgery after coronary angioplasty: The National Heart, Lung, and Blood Institute’s Percutaneous Transluminal Coronary Angioplasty Registry Experience. Am J Cardiol 53: 22C–26C.PubMedCrossRefGoogle Scholar
  3. 3.
    Serruys PW, Luijten HE, Beatt KJ, Gueskens R, et al. (1988). Incidence of restenosis after successful coronary angioplasty: A time-related phenomenon. A quantitative angiographic study in 342 patients at 1, 2, 3, and 4 months. Circulation 77: 361.PubMedCrossRefGoogle Scholar
  4. 4.
    Nobuyoshi M, Kimura T, Nosaka H, Moika S, et al. (1988). Restenosis after successful percutaneous transluminal coronary angioplasty: Serial angiographic follow-up of 229 patients. J Am Coll Cardiol 12: 616.PubMedGoogle Scholar
  5. 5.
    Hiehle JF, Bourgelais DBC, Shapshay S, Schoen FJ, et al. (1985). Nd:YAG laser fusion of human atheromatous plaque-arterial wall separations in vitro. Am J Cardiol 56: 953–957.PubMedCrossRefGoogle Scholar
  6. 6.
    Spears JR (1987). PTCA restenosis: Potential prevention with laser balloon angioplasty (LBA). Am J Cardiol 60: 61B–64B.PubMedCrossRefGoogle Scholar
  7. 7.
    Spears JR (1989). Sealing. In Cardiovascular Laser Therapy, JM Isner, RH Clarke, eds. New York: Raven Press, pp 177–199.Google Scholar
  8. 8.
    Serur JR, Sinclair IN, Spokojny AM, Paulin S, et al. (1985). Laser balloon angioplasty (LBA): Effect on the carotid lumen in the dog. Circulation 72: 111–457.Google Scholar
  9. 9.
    Jenkins RD, Sinclair IN, Leonard BM, Sandor T, et al. (1989). Laser balloon angioplasty in normal rabbit iliac arteries. Lasers Surg Med, in press.Google Scholar
  10. 10.
    Welch AJ, Valvano JW, Pearce JA, Hayes LJ, et al. (1985). Effect of laser radiation on tissue during laser angioplasty. Lasers Surg Med 5: 251.PubMedCrossRefGoogle Scholar
  11. 11.
    Gorisch W, Boergen KP (1979). Thermal shrinkage of collagen fibers during occlusion in laser surgery. In Laser Surgery, Vol III, I. Kaplan, ed. Jerusalem: Academic Press, pp 202–207.Google Scholar
  12. 12.
    Kaltenbach M, Beyer J, Walter S, Klepzig H, et al. (1984). Prolonged application of pressure in transluminal coronary angioplasty. Cath Cardiovasc Diagn 10: 213.CrossRefGoogle Scholar
  13. 1’3. Peterson LH, Jensen RE, Parnell J (I960). Mechanical properties of arteries in vivo. Circ Res 8: 622.Google Scholar
  14. 14.
    Gow BS (1970). Viscoelastic properties of conduit arteries. Circ Res 26(Suppl II):II — 113.Google Scholar
  15. 15.
    Spears JR, Sandor T, Als AV, Malagold M, et al. (1983). Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. Circulation 68:453– 461.Google Scholar
  16. 16.
    Sandor T, D’Adamo A, Hanlon WB, Spears JR. (1987). High precision quantitative angiography. IEEE Trans Med Imaging MI-6:258– 265.Google Scholar
  17. 17.
    Spears JR, Sandor T (1986). Quantitation of coronary artery stenosis severity: Limitations of angiography and computerized information ex–traction. In State of the Art in Quantitative Coronary Arteriography, J HC Reiber, PW Serrys, eds. Amsterdam: Martinus Nijhoff Publishers, pp 103–124.Google Scholar
  18. 18.
    Steele PM, Chesebro JH, Stanson AW, Holmes DR Jr, et al. (1985). Balloon angioplasty. Natural history of the pathological response to injury in a pig model. Circ Res 57: 105.PubMedGoogle Scholar
  19. 19.
    Lee G, Ikeda RM, Theis JH, Chan MC, et al. (1984). Acute and chronic complications of laser angioplasty: Vascular wall damage and formation of aneurysms in the atherosclerotic rabbit. Am J Cardiol 53: 290–293.PubMedCrossRefGoogle Scholar
  20. 20.
    Cumberland DC, Storkey IR, Oakley GDG, et al. (1986). Percutaneous laser-assisted coronary angioplasty. Lancet 11: 214.CrossRefGoogle Scholar
  21. 21.
    Sinclair IN, Jenkins RD, James LM, Sinofsky EL, et al. (1988). Effect of laser balloon angioplasty on normal dog coronary arteries in vivo (abstr). J Am Coll Cardiol II (Suppl): 108A.Google Scholar
  22. 22.
    Jenkins RD, Sinclair IN, Anand R, Kalil AG, et al. (1988). Laser balloon angioplasty: Effect of tissue temperature on weld strength of human postmortem intima-media separations. Lasers Surg Med 8: 30–39.PubMedCrossRefGoogle Scholar
  23. 23.
    Anand RK, Sinclair IN, Jenkins RD, Hiehle JF Jr, et al. (1988). Laser balloon angioplasty: Effect of constant temperature versus constant power on tissue weld strength. Lasers Surg Med 8: 40–44.PubMedCrossRefGoogle Scholar
  24. 24.
    Jenkins RD, Sinclair IN, Anand RK, James LM, et al. (1988). Laser balloon angioplasty: Effect of exposure duration on shear strength of welded layers of postmortem human aorta. Lasers Surg Med 8: 392–396.PubMedCrossRefGoogle Scholar
  25. 25.
    Spears JR, James LM, Leonard BM, Sinclair IN, et al. (1988). Plaque-media rewelding with reversible tissue optical property changes during repetitive CW Nd: YAG laser exposure. Lasers Surg Med 8: 477–485.PubMedCrossRefGoogle Scholar
  26. 26.
    Sinclair IN, Anand RK, Kalil AG, Jr., Schoen FJ, et al. (1986). Laser balloon angioplasty: Factors affecting plaque–arterial wall thermal “weld” strength. Circulation 74: 11–203.Google Scholar
  27. 27.
    Klink F, Grosspietzch R, von Klitzing L, Endeil W, et al. (1978). Animal in-vivo studies and in–vitro experiments with human tubes for end–to–end anastomotic operation by a C02 laser technique. Fertil Stgeril 30: 100.Google Scholar
  28. 28.
    Jain KK, Gorisch W (1979). Repair of small blood vessels with the Neodymium-YAG laser: A preliminary report. Surgery 85: 684.PubMedGoogle Scholar
  29. 29.
    Gomes OM, Macruz R, Armelin E, Ribeiro MP, et al. (1983). Vascular anastomosis by argon laser beam. Texas Heart Inst J 10: 145.Google Scholar
  30. 30.
    Frazier OH, Painvin A, Morris JR, Thomsen S, et al. (1985). Laser-assisted microvascular anastomoses: Angiographic and anatomopathologic studies on growing microvascular anastomoses: Preliminary report. Surgery 97: 585.PubMedGoogle Scholar
  31. 31.
    White RA, Kopchok G, Donayre C, Abergel RP, et al. (1986). Comparison of laser-welded and sutured arteriotomies. Arch Surg 121: 1133.PubMedGoogle Scholar
  32. 32.
    Sauer JS, Rogers DW, Hinshaw JR (1986). Bursting pressures of C02 laser-welded rabbit ileum. Lasers Surg Med 6: 106.PubMedCrossRefGoogle Scholar
  33. 33.
    Higgins T (1987). Computer control helps Nd: YAG laser fuse tissue. Lasers & Applications 6: 22.Google Scholar
  34. 34.
    Schober R, Ulrich F, Sander T, Durselen H, et al. (1986). Laser-induced alteration of collagen substructure allows microsurgical tissue welding. Science 232: 1421.PubMedCrossRefGoogle Scholar
  35. 35.
    Sigel B, Dunn MR. (1965). The mechanism of blood vessel closure by high frequency electrocoagulation. Surg Gynecol Obstet 121: 823.PubMedGoogle Scholar
  36. 36.
    Sigel B, Acevedo FJ (1963). Electrocoaptive union of blood vessels: A preliminary experimental study. J Surg Res 111: 90.CrossRefGoogle Scholar
  37. 37.
    Marchesini R, Andreola, Emanuelli H, Melloni E, et al. (1985). Temperature rise in biological tissue during Nd: YAG laser irradiation. Lasers Surg Med 5: 75.PubMedCrossRefGoogle Scholar
  38. 38.
    Sanborn TA, Sinclair IN, Serur JR, Spokojny AM, et al. (1985). In vivo laser thermal seal of neointimal dissection after balloon angioplasty in rabbit atherosclerosis. Circulation 72: 111–469.Google Scholar
  39. 39.
    Jenkins RD, Sinclair IN, McCall PE, Schoen FJ, et al. (1989). Thermal sealing of arterial dissections and perforations in atherosclerotic rabbits with laser balloon angioplasty. Lasers in Life Sciences 3: 18.Google Scholar
  40. 40.
    Fields CD, Gal D, Rongione AJ, ErBin L, et al. (1988). Acute effect of laser-thermal enhancement of neoluminal intima—“G-lasing” —following balloon angioplasty. Circulation 78 (Suppl II): II–503.Google Scholar
  41. 41.
    Wood GC (1963). Spectral changes accompanying the thermal denaturation of collagen. Biochem Biophys Res Commun 13: 95–99.CrossRefGoogle Scholar
  42. 42.
    Ansevin AT, Vizard DL, Brown BW, McConathy J (1976). High-resolution thermal denaturation of DNA. I. Theoretical and practical considerations for the resolution of thermal subtransitions. Biopolymers 15: 153–174.PubMedCrossRefGoogle Scholar
  43. 43.
    Marcos NC, Berns M, Henry WL (1988). Effect of laser–heated tip angioplasty on human athero-sclerotic coronary arteries. Lasers Surg Med 8: 22–29.CrossRefGoogle Scholar
  44. 44.
    Spears JR, Reyes VP, James LM, Sinofsky EL (1988). Laser balloon angioplasty: Initial clinical percutaneous coronary results. Circulation 78 (Suppl II): II–296.Google Scholar
  45. 45.
    Spears JR, Reyes VP, Sinclair IN, Hopkins, B, et al. (1989). Percutaneous coronary laser balloon angioplasty: Preliminary results of a multi-center trial (abstr). J Am Col Cardiol, in press.Google Scholar

Copyright information

© Kluwer Academic Publishers 1990

Authors and Affiliations

  • J. Richard Spears
  • I. Nigel Sinclair
  • Ronald D. Jenkins

There are no affiliations available

Personalised recommendations