Abstract
High resolution magnetocardiography (HR MCG) is a new and promising method of studying heart activity. One of the most interesting clinical applications of HR MCG is the localization of pathological cardiac sources which has often been demonstrated (Erné, 1985, Fenici et al., 1985, Katila et al., 1987). For the localization appropriate source and thorax models are needed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Burghoff, M., Haberkorn, W., and Albrecht, G.,1988, Localization of cardiomagnetic field sources based on the multipole expansion, in: Proc. 20th Int. Symp. L.T.P., in press.
Erné, S.N., 1985, High resolution magnetocardiography: modeling and source localization, in: Proc. XIV ICMBE, 1447.
Fenici, R.R., Masselli, M., Erné, S.N., and Hahlbohm, H.-D., 1985, Magnetocardiographic mapping of the P-R interval phenomena in an unshielded hospital laboratory, in: Biomagnetism: Applications & Theory, Edited by H. Weinberg et al., Pergamon Press, New York, 137.
Katila, T.E., 1983, On the current multipole presentation of the primary current distributions, Il Nuovo Cimento 2D., 660.
Katila, T., Montonen, J., Mäkijärvi, M., Nenonen, J., Raivio, M., and Siltanen, P., Localization of the accessory cardiac conduction pathway, in: Biomagnetism’87, Edited by K. Atsumi et al. Tokyo Denki University Press, 274.
Nowak, H., Albrecht, G., Berthel, K.-H., Burghoff, M., Haberkorn, W., Zach, H.-G., 1988, Biomagnetic measurements in unshielded environment, in: Advances in Biomedical Measurement, Edited by E. R. Carson et al., Plenum Press, New York and London, 161.
Schmitz, L., 1987, Magnetocardiography: the clinician’s point of view, in: Biomagnetism’87, Edited by K. Atsumi et al., Tokyo Denki University Press, 66.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1989 Plenum Press, New York
About this chapter
Cite this chapter
Albrecht, G., Burghoff, M., Gießler, F., Haberkorn, W., Nowak, H. (1989). High Resolution Magnetocardiography, Source Localization and Multichannel Magnetometry. In: Williamson, S.J., Hoke, M., Stroink, G., Kotani, M. (eds) Advances in Biomagnetism. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-0581-1_73
Download citation
DOI: https://doi.org/10.1007/978-1-4613-0581-1_73
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4612-7876-4
Online ISBN: 978-1-4613-0581-1
eBook Packages: Springer Book Archive