Abstract

Adequate imaging to allow percise visualization of the septum and defect is a cornerstone of the patent foramen ovale closure procedure. The advent of intracardiac echocardiography has allowed for very accurate imaging capabilities while allowing the patient to remain awake for the procedure. In this chapter the authors review options for intracardiac echocardiography imaging and go through the protocol used for patent foramen ovale closure.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   159.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Cieszynski T. Intracardiac method for the investigation of structure of the heart with the aid of ultrasonics. Arch Immunol Ther Exp. 1960;8:551–7.

    CAS  Google Scholar 

  2. Ludomirsky A, Rivou F, Weintraub R, Sahn DJ. Applications of intravascular scanning in congenital heart disease. In: Tobis JM, Yoe P, editors. Intravascular ultrasound imagining. New York: Churchill Livingstone Publisher; 1992. p. 247–52.

    Google Scholar 

  3. Pandian NG, Kreis A, Brockway B, Isner JM, Sacharoff A, Boleza E, Caro R, Muller D. Ultrasound angioscopy: real time intravascular ultrasound imaging in humans. Am J Cardiol. 1990;65:1392–6.

    Article  CAS  PubMed  Google Scholar 

  4. Pandian NG, Kreis A, Weintraub A, Motarjeme A, Desnoyers M, Isner JM, Konstam M, Salem DN, Millen V. Real time intravascular imaging in humans. Am J Cardiol. 1990;65:1392–6.

    Article  CAS  PubMed  Google Scholar 

  5. Fisher JP, Wolfberg CA, Mikan JS, et al. Intracardiac ultrasound determination of left ventricular volumes: in vitro and in vivo validation. J Am Coll Cardiol. 1994;24:247–53.

    Article  CAS  PubMed  Google Scholar 

  6. Vazquez de Prada JA, Chen MH, Guerrero JL, et al. Intracardiac echocardiography: in vitro and in vivo validation for right ventricular volume and function. Am Heart J. 1996;131:320–8.

    Article  CAS  PubMed  Google Scholar 

  7. Valdes-Cruz IM, Sideris E, Sahn DJ, Murillo-Olivas A, Knudson O, Omoto R, Kyo S, Gulde R. Transvascular intracardiac application so f a miniaturized phased aray ultrasonic endoscope initial experience with intracardiac imagining in piglets. Circulation. 1991;83:1023–7.

    Article  CAS  PubMed  Google Scholar 

  8. HIjazi ZM, Wang Z, Cao QL, Koenig P, Waight D, Lang R. Transcatheter closure of atrial septal defect and patent foramen ovale under intracardiac echocardiographic guidance: feasibility and comparison with transesophageal echocardiography. Catheter Cardiovasc Interv. 2001;52:194–9.

    Article  CAS  PubMed  Google Scholar 

  9. Hellenbrand WE, Fahey JT, McGowan FX, Weltin GG, Kleinman CS. Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol. 1990;66:207–13.

    Article  CAS  PubMed  Google Scholar 

  10. Kim SS, Hijazi ZM, Lang RM, Knight BP. The use of intracardiac echocardiography and other intracardiac imaging tools to guide noncoronary cardiac interventions. J Am Coll Cardiol. 2009;53:2117–28.

    Article  PubMed  Google Scholar 

  11. Alboliras ET, Hijazi ZM. Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults. Am J Cardiol. 2004;94:690–2.

    Article  PubMed  Google Scholar 

  12. Koenig PR, Abdulla RI, Cao QL, HIjazi ZM. Use of intracardiac echocardiography to guide catheter closure of atrial communications. Echocardiography. 2003;20:781–7.

    Article  PubMed  Google Scholar 

  13. Hijazi ZM, Shivkumar K, Sahn D. Intracardiac Echocardiography during interventional and electrophysiological cardiac catheterization. Circulation. 2008;119:587–96.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ziyad M. Hijazi MD, MPH .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer-Verlag London

About this chapter

Cite this chapter

Holoshitz, N., Hijazi, Z.M. (2015). ICE: Intra-Procedural Evaluation and Guidance During Closure of PFO. In: Amin, Z., Tobis, J., Sievert, H., Carroll, J. (eds) Patent Foramen Ovale. Springer, London. https://doi.org/10.1007/978-1-4471-4987-3_6

Download citation

  • DOI: https://doi.org/10.1007/978-1-4471-4987-3_6

  • Published:

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-4471-4986-6

  • Online ISBN: 978-1-4471-4987-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics