Abstract
This research is based on high performance liquid chromatographic method for the determination of bisphenol A, nonylphenol and octylphenol in sewage. Sewage samples use dispersive liquid–liquid extraction-pre column derivatization-High performance liquid chromatography method for the determination. Dichloromethane is extracting agent. Acetonitrile and water (V:V = 90:10) are mobile phase. Bisphenol A, nonylphenol and octylphenol detect by Inertsil ODS-P column (5 μm, 250 × 4.6 mm) after the separation of fluorescence. Fluorescence excitation wavelength is 227 nm. The emission wavelength is 313 nm. Sample complete in 6 min within the peak. Linear range is 0.1−10 mg/L. In 0.1, 0.5 and 1 mg/L three concentrations of added level of sewage recovery of samples are respectively 94.7–106.8 %. The method is simple, rapid and economic actual samples. It can be used for sewage.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Xiao J, Shao B, Wu XY et al (2011) A study on bisphenol A, nonylphenol, and octyphenol in human urine amples detected by SPE-UPLC-MS. Biomed Environ Sci 24(1):40–46
Cooper JE, Kendig EL, Belcher SM (2011) Assessment of bisphenol A released from reusable plastic, aluminium and stainless steel water bottles. Chemosphere 85(6):943–947
Yiantzi E, Psillakis E, Tyrovola K et al (2010) Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol A. Talanta 80(5):2057–2062
Langdon KA, Warne MSJ, Smernik RJ et al (2011) Degradation of 4-nonylphenol, 4-t-octyphenol, bisphenol A and triclosan following biosolids addition to soil under laboratory conditions. Chemosphere 84(11):1556–1562
Zhou Q, Gao Y, Xie G (2011) Determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octyphenol by temperature-controlled ionic liquid dispersive liquid-phase microextraction combined with high performance liquid chromatography-fluorescence detector. Talanta 85(3):1598–1602
Ferrer E, Santoni E, Vittori S et al (2011) Simultaneous determination of bisphenol A, octyphenol, and nonylphenol by pressurized liquid extraction and liquid chromatography tandem mass spectrometry in powdered milk and infant formulas. Food Chem 126(1):360–367
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag London
About this paper
Cite this paper
Qian, Q., Cao, X., Wang, Q., Cao, Y., Rong, S., Yu, S. (2013). High-Performance Liquid Chromatographic Method for the Determination of Bisphenol A, Nonylphenol and Octylphenol in Sewage. In: Du, W. (eds) Informatics and Management Science I. Lecture Notes in Electrical Engineering, vol 204. Springer, London. https://doi.org/10.1007/978-1-4471-4802-9_91
Download citation
DOI: https://doi.org/10.1007/978-1-4471-4802-9_91
Published:
Publisher Name: Springer, London
Print ISBN: 978-1-4471-4801-2
Online ISBN: 978-1-4471-4802-9
eBook Packages: EngineeringEngineering (R0)