Abstract
Mesh fixation in laparoscopic ventral hernia benefits from a wide range of devices and materials that can be used, according to the location and characteristics of both the hernia and mesh. At our disposal are sutures (metal, traumatic, plastic, absorbable) and adhesives. The advantages of fibrin have been incorporated into traditional metal sutures (tackers), offering potential improvements in terms of integration and the decrease of possible complications (seroma, hematoma, etc.).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
LeBlanc KA. Laparoscopic incisional hernia repair: are transfascial sutures necessary? A review of the literature. Surg Endosc. 2007;21(4):508–13.
LeBlanc KA, Booth WV, Whitaker JM, Bellanger DE. Laparoscopic incisional and ventral herniorraphy: our initial 100 patients. Hernia. 2001;5(1):41–5.
Forbes SS, Eskicioglu C, McLeod RS, Okrainec A. Metaanalysis of randomized controlled trials comparing open and laparoscopic ventral and incisional hernia repair with mesh. Br J Surg. 2009;96:851–85.
Sauerland S, Walgenbach M, Habermalz B, Seiler CM, Miserez M. Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. Cochrane Database Syst Rev. 2011;16(3):CD007781.
Brill JB, Turner PL. Long-term outcomes with transfascial sutures versus tacks in laparoscopic ventral hernia repair: a review. Am Surg. 2011;77:458–65.
Clarke T, Katkhouda N, Mason RJ, Cheng BC, Algra J, Olasky J, Sohn HJ, Moazzez A, Balouch M. Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model. Surg Endosc. 2011;25:737–48.
Morales-Conde S, Cadet H, Cano H, Bustos M, Martín J, Morales-Mendez S. Laparoscopic ventral hernia repair without sutures—double crown technique: our experience after 140 cases with a mean follow-up of 40 months. Int Surg. 2005;90(3 Suppl):S56–62.
Wassenaar E, Schoenmaeckers E, Raymakers J, van der Palen J, Rakic S. Mesh-fixation method and pain and quality of life after laparoscopic ventral or incisional hernia repair: a randomized trial of three fixation techniques. Surg Endosc. 2010;24:1296–302.
Chelala E, Thoma M, Tatete B, Lemye AC, Dessily M, Alle JL. The suturing concept for laparoscopic mesh fixation in ventral and incisional hernia repair: mid-term analysis of 400 cases. Surg Endosc. 2007;21:391–5.
Bansal VK, Misra MC, Babu D, Singhal P, Rao K, Sagar R, Kumar S, Rajeshwari S, Rewari V. Comparison of long-term outcome and quality of life after laparoscopic repair of incisional and ventral hernias with suture fixation with and without tacks: a prospective, randomized, controlled study. Surg Endosc. 2012;26:3476–85.
LeBlanc KA. Laparoscopic incisional and ventral hernia repair: complications—how to avoid and handle. Hernia. 2004;8:323–31.
Hollinsky C, Göbl S. Bursting strength evaluation after different types of mesh fixation in laparoscopic herniorrhaphy. Surg Endosc. 1999;13(10):958–61.
Duffy AJ, Hogle NJ, LaPerle KM, Fowler DL. Comparison of two composite meshes using two fixation devices in a porcine laparoscopic ventral hernia repair model. Hernia. 2004;8(4):358–64.
Olmi S, Scaini A, Erba L, Croce E. Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience. Surg Endosc. 2007;21:409–13.
Eriksen JR, Bisgaard T, Assaadzadeh S, Jorgensen LN, Rosenberg J. Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study. Hernia. 2013;17(4):511–4.
Eriksen JR, Bisgaard T, Assaadzadeh S, Nannestad Jorgensen L, Rosenberg J. Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical. Hernia repair. Br J Surg. 2011;98:1537–45.
Reynvoet E, Berrevoet F, De Somer F, Vercauteren G, Vanoverbeke I, Chiers K, Troisi R. Tensile strength testing for resorbable mesh fixation systems n laparoscopic ventral hernia repair. Surg Endosc. 2012;26:2513–20.
Carbajo MA, Martp del Olmo JC, Blanco JI, Toledano M, de la Cuesta C, Ferreras C, Vaquero C. Laparoscopic approach to incisional hernia. Surg Endosc. 2003;17(1):118–22.
Bageacu S, Blanc P, Breton C, Gonzales M, Porcheron J, Chabert M, Balique JG. Laparoscopic repair of incisional hernia: a retrospective study of 159 patients. Surg Endosc. 2002;16(2):345–8.
Morales-Conde S, Barranco A, Socas M, Alarcón I, Grau M, Casado MA. Systematic review of the use of fibrin sealant in abdominal-wall repair surgery. Hernia. 2011;15(4):361–9.
Nebinger D, et al., Covidien. Biomechanical, benchtop evaluation of the shear holding force of various fixation devices used in hernia repair. In: Poster presented at Hernia 2012, 5th international Hernia Congress, New York City, Mar 2012.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer-Verlag London
About this chapter
Cite this chapter
de la Cuadra, B.M., Hernandez, J.V., Grau, J.M.S. (2014). Fixation of Prostheses in Laparoscopic Ventral Hernia Repair. In: Suárez Grau, J., Bellido Luque, J. (eds) Advances in Laparoscopy of the Abdominal Wall Hernia. Springer, London. https://doi.org/10.1007/978-1-4471-4700-8_11
Download citation
DOI: https://doi.org/10.1007/978-1-4471-4700-8_11
Published:
Publisher Name: Springer, London
Print ISBN: 978-1-4471-4699-5
Online ISBN: 978-1-4471-4700-8
eBook Packages: MedicineMedicine (R0)