Abstract
In recent years technological advances in power electronics have facilitated the development of electronic equipments that offer the ability to handle large amounts of power; consequently, the use and application of this technology into electrical power systems have increased significantly. These electronic devices, called Flexible AC Transmission System (FACTS), are based on electronic power converters and they provide the ability to make quick adjustments and to control the electrical system. FACTS devices can be connected in series, in parallel, or in a combination of both. The benefits they offer to the electrical grid are widely referenced in scientific literature. These benefits include improvement of the stability of the grid, control of the flow of active and reactive power on the grid, loss minimization, and increased grid efficiency.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Hingorani NG, Gyugyi L (1999) Undestanding FACTS. IEEE Press, New York
Mithulananthan N, Canizares CA, Reeve J, Rogers GJ (2003) Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations. IEEE Trans Power Syst 18(2):786–792
Moore P, Ashmole P (1998) Flexible AC transmission systems. 4. Advanced FACTS controllers. Power Eng J 12(2):95–100
Zhang X-P, Rehtanz C, Pal B (2006) Flexible AC transmission systems: modelling and control. Springer, Berlin
Amaris H, Alonso M (2011) Coordinated reactive power management in power networks with wind turbines and FACTS devices. Energ Convers Manage 52(7):2575–2586
Saad-Saoud Z, Lisboa ML, Ekanayake JB, Jenkins N, Strbac G (1998) Application of STATCOM’s to wind farms. IEE Proc Gener Trans Distrib 145(5):511–516
Sobtink KH, Renz KW, Tyll H (1998) Operational experience and field tests of the SVG at Rejsby Hede. In: International conference on power system technology proceedings, POWERCON’98, vol 1, Zhejiang, pp 318–322
Han C, Huang AQ, Baran ME, Bhattacharya S, Litzenberger W, Anderson L, Johnson AL, Edris A (2008) STATCOM impact study on the integration of a large wind farm into a weak loop power system. IEEE Trans Energ Convers 23(1):1266–1272
Molinas M, Are Suul J, Undeland T (2008) Low voltage ride through of wind farms with cage generators: STATCOM versus SVC. IEEE Trans Power Electron 23(3):1104–1117
Qiao W, Harley RG, Venayagamoorthy GK (2009) Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming. IEEE Trans Energ Convers 24(2):493–503
Molinas M, Vazquez S, Takaku T, Carrasco JM, Shimada R, Undeland T (2005) Improvement of transient stability margin in power systems with integrated wind generation using a STATCOM: an experimental verification. In: International conference on future power systems, vol 1, pp 1–6
Zhang W (2007) Optimal sizing and location of static and dynamic reactive power compensation. PhD thesis, University of Tennessee, Knoxville
Han C, Yang Z, Chen B, Song W, Huang AQ, Edris A, Ingram M, Atcitty S (2005) System integration and demonstration of a 4.5 MVA STATCOM based on emitter turn-off (ETO) thyristor and cascade multilevel converter. In: 31st annual conference of IEEE Industrial Electronics Society, IECON 2005, Raleigh, pp 1329–1334
Lam C-S, Wong M-C, Han Y-D (2004) Stability study on dynamic voltage restorer (DVR). In: Proceedings of the first international conference on power electronics systems and applications, Hong Kong, China, pp 66–71
Alvarez C, Amaris H (2006) Voltage dips compensation in wind farms using dynamic voltage restorer. In: Proceedings of the 5th international Nordic workshop on power and industrial electronics, NORPIE 2006, Aalborg
Nielsen JG, Newman M, Nielsen H, Blaabjerg F (2004) Control and testing of a dynamic voltage restorer (DVR) at medium voltage level. IEEE Trans Power Electron 19(3):806–813
Lobos T, Rezmer J, Janik P, Amaris H, Alonso M, Alvarez C (2009) Application of wavelets and prony method for disturbance detection in fixed speed wind farms. Int J Electron Power Energ Syst 31:429–436
Meyer C, De Doncker RW, Wei Li Y, Blaabjerg F (2008) Optimized control strategy for a medium-voltage DVR – theoretical investigations and experimental results. IEEE Trans Power Electron 23(6):2746–2754
P.O. 12.3. Requisitos de Respuesta frente a Huecos de Tensión de las Instalaciones Eólicas, Resolución del Ministerio de Industria, Oct 2006. (In Spanish)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2013 Springer-Verlag London
About this chapter
Cite this chapter
Amaris, H., Alonso, M., Ortega, C.A. (2013). Facts Devices. In: Reactive Power Management of Power Networks with Wind Generation. Lecture Notes in Energy, vol 5. Springer, London. https://doi.org/10.1007/978-1-4471-4667-4_2
Download citation
DOI: https://doi.org/10.1007/978-1-4471-4667-4_2
Published:
Publisher Name: Springer, London
Print ISBN: 978-1-4471-4666-7
Online ISBN: 978-1-4471-4667-4
eBook Packages: EnergyEnergy (R0)