Neurometric Assessment of Adequacy of Intraoperative Anaesthetic

  • Lars J. Kangas
  • Paul E. Keller
Part of the Perspectives in Neural Computing book series (PERSPECT.NEURAL)

Abstract

In collaboration with Cadwell Laboratories, Inc. of Kennewick, Washington, USA and Dr. Harvey L. Edmonds at the University of Louisville in Louisville, Kentucky, USA, Pacific Northwest National Laboratory has applied artificial neural networks to advance the analytical technology required to perform computer-based assessments of adequacy of intraoperative anaesthesia.

Keywords

Ischemia Hydrocarbon Morphine Midazolam Isoflurane 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    Ackerman, W., Andrews, P., Juneja, M., Cases-Cristobal, V., Edmonds, H., and Rigor, B. Sensory evoked facial muscle electromyography for the quantification of acute labor pain. KMA Journal, 92:14–18, January 1994.Google Scholar
  2. [2]
    Couture, L., and Edmonds, H. Monitoring responsiveness during anaesthesia. Bailliere’s Clinical Anaesthesiology, 3(3):547–558, December 1989.CrossRefGoogle Scholar
  3. [3]
    Desiderio, D. Patient awareness under general anesthesia. Cancer Investigation, 11(2):185–189, 1993.CrossRefGoogle Scholar
  4. [4]
    Edmonds, H. Anesthetic adequacy, surface EMG and quantitated EEG. Acta Anaesthesiology Scandinavia 1993, 37(S 100): 102–104, 1993.CrossRefGoogle Scholar
  5. [5]
    Edmonds, H. Assessment of anesthetic adequacy for the prevention of intraoperative awareness, Progress in Anesthesiology, VI(21), November 1992.Google Scholar
  6. [6]
    Edmonds, H., Andrews, P., Ackerman, W., Tabatabai, A., Juneja, M., Cases-Cristobal, V., and Vogel, R. Facial EMG quantifies anxiety and anesthetic adequacy during labor, in press. Memory and Awareness in Anaesthesia, Ed. P. Sebel, Simon & Schuster, 1992.Google Scholar
  7. [7]
    Edmonds, H. Intraoperative EEG monitoring. Progress in Anesthesiology, VI,(18), September1992.Google Scholar
  8. [8]
    Edmonds, H. Monitoring of Cerebral Ischemia. Cerebral Ischemia and Resuscitation, Eds. A. Schurr and B. Rigor, CRC Press, pp. 413–429, 1990.Google Scholar
  9. [9]
    Edmonds, H. Surface electromyography during low vigilance states. Consciousness Awareness and Pain in General Anesthesia, Eds. M. Rosen and J. Lunn, Butterworths, 1987.Google Scholar
  10. [10]
    Ghouri, A., Monk, T., and White, P. Electroencephalogram spectral edge frequency, lower esophageal contractility, and autonomic responsiveness during general anesthesia. Journal of Clinical Monitoring, 9(3):176–185, 1993.CrossRefGoogle Scholar
  11. [11]
    Gurman, G. Assessment of depth of general anesthesia. International Journal of Clinical Monitoring and Computing, Kluwer Academic Publishers, 11:185–189, 1994.CrossRefGoogle Scholar
  12. [12]
    Huffman, L. AANA Journal course: New technologies in anesthesia: Update for nurse anesthetics - Monitoring depth of anaesthesia using a reliable esophageal method. Journal of the American Association of Nurse Anesthetists, 57:142–152, April 1989.Google Scholar
  13. [13]
    Jasper, H. H. The Ten-Twenty electrode system of the international federation. Electroencephalogram and Clinical Neurophysiology, 10:371–375, 1958.Google Scholar
  14. [14]
    Kiviniemi, K Conscious awareness and memory during general anaesthesia. American Association of Nurse Anesthetists Journal, 62(5):441–449, October 1994.Google Scholar
  15. [15]
    Moerman, N., Bonke, B., and Oosting, J. Awareness and recall during general anesthesia. Anesthesiology, 79:545–464, September 1993.CrossRefGoogle Scholar
  16. [16]
    Muthuswamy, J., and Roy, R. Bispectrum analysis of EEG of a dog to determine the depth under halothane anesthesia. IEEE, 5–6, 1993.Google Scholar
  17. [17]
    Prichep, L., Lieber, A., John, E., Alper, K., Gomez-Mont, F., Essig-Peppard, T., and Flitter, M. Quantitative EEG in depressive disorders, in press, Electrical Brain Potentials and Psychopathology, Ed. C. Shagass, Elsevier, 1986.Google Scholar
  18. [18]
    Rodriguez, R., Edmonds, H., and Schroeder, J. Quantitative EEG analysis in a case of awareness during cardiac surgery. Electroencephalography and Clinical Neurophysiology, 87:250–253, 1993.CrossRefGoogle Scholar
  19. [19]
    Sharma, A., and Roy, R. Design of a recognition system to monitor the depth of anesthesia, Becton Dickinson and Company.Google Scholar
  20. [20]
    Yli-Hankala, A., Edmonds, H., Heine, M., Strickland, T., Tseuda, K. Auditory steady state response, upper facial EMG, EEG and heart rate as predictors of movement after isoflurane-nitrous oxide anesthesia, in press, British Journal of Anesthesia. Google Scholar
  21. [21]
    Zbinden, A., Petersen-Felix, S., Thomsen, D., and Anaes, F. Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia, II. Hemodynamic Responses. Anesthesiology, J.B. Lippincott Company, 80:261–267, Feb. 1994.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag London 2000

Authors and Affiliations

  • Lars J. Kangas
    • 1
  • Paul E. Keller
    • 1
  1. 1.Pacific Northwest National LaboratoryRichlandUSA

Personalised recommendations