Top-ups versus infusions and patient-controlled epidural analgesia (PCEA)

  • David R. Gambling

Abstract

The future of PCEA is in the hands of clinicians around the world. It remains to be seen if the technique becomes universally employed. This may well depend on economic (price of the PCA pump), technical (development of simple, portable, PCA devices), social (consumer demand) and scientific factors (unrealised advantages or disadvantages of PCEA determined by large, randomised clinical trials). Theoretically, it is hard to argue with the PCEA concept since it restores an element of control to the parturient, and allows instantaneous epidural dosing. Despite earlier concerns,42 the safety of PCEA over the past decade has been shown to be comparable to other available techniques and the advantages of PCEA make it a compelling first option for epidural drug delivery in the new millennium.

Keywords

Placebo Migration Catheter Titration Syringe 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Purdy G, Currie J, Owen H. Continuous extradural analgesia in labour. Comparison between “on demand” and regular “top-up” injection. Br J Anaesth 1987; 59: 319–24PubMedCrossRefGoogle Scholar
  2. 2.
    Plummer JL, Brownridge P. Epidural analgesia in labour using intermittent doses determined by midwives. International Journal of Obstetric Anesthesia 1998; 7: 88–97PubMedCrossRefGoogle Scholar
  3. 3.
    Milaszkiewicz R, Payne N, Loughnan B, Blackett A, Barber N, Carli F. Continuous extradural infusion of lignocaine 0.75% vs. bupivacaine 0.125% in primiparae: Quality of analgesia and influence on labour. Anaesthesia 1992; 47: 1042–6Google Scholar
  4. 4.
    Christiaens F, Verborgh C, Dierick A, Camu F. Effects of diluent volume of a single dose of epidural bupivacaine in parturients during the first stage of labor. Reg Anesth Pain Med 1998; 23: 134–41PubMedCrossRefGoogle Scholar
  5. 5.
    McMorland GH, Douglas MJ, Jeffery WK et al. Effect of pH-adjustment of bupivacaine on onset and duration of epidural analgesia in parturients. Can Anaesth Soc J 1986; 33: 537–41PubMedCrossRefGoogle Scholar
  6. 6.
    Capogna G, Celleno D, Lyons G, Columb M, Fusco P. Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour. Brit J Anaesth 1998; 80: 11–3PubMedCrossRefGoogle Scholar
  7. 7.
    Taylor H. Clinical experience with continuous epidural infusion of bupivacaine at 6 ml per hour in obstetrics. Can Anaesth Soc J 1983; 30: 278–86CrossRefGoogle Scholar
  8. 8.
    Gaylard DG, Wilson IH, Balmer HG. An epidural infusion technique for labour. Anaesthesia 1987; 42: 1098–101PubMedCrossRefGoogle Scholar
  9. 9.
    Smedsted KG, Morison DH. A comparative study of continuous and intermittent epidural analgesia for labour and delivery. Can J Anaesth 1988; 35: 234–41CrossRefGoogle Scholar
  10. 10.
    Hicks JA, Jenkins JG, Newton MC, Findley IL. Continuous epidural infusion of 0.075% bupivacaine for pain relief in labour. A comparison with intermittent top-ups of 0.5% bupivacaine. Anaesthesia 1988; 43: 289–92PubMedCrossRefGoogle Scholar
  11. 11.
    Lamont RF, Pinney D, Rodgers P, Bryant TN. Continuous versus intermittent epidural analgesia. A randomised trial to observe obstetric outcome. Anaesthesia 1989; 44: 893–6PubMedCrossRefGoogle Scholar
  12. 12.
    Eddleston JM, Maresh M, Horsman EL, Young H, Lacey P, Anderton J. Comparison of the maternal and fetal effects associated with intermittent or continuous infusion of extradural analgesia. Br J Anaesth 1992; 69: 154–8PubMedCrossRefGoogle Scholar
  13. 13.
    Gambling DR, McMorland GH, Yu P, Laszlo C. Comparison of patient-controlled epidural analgesia and conventional intermittent “top-up” injections during labor. Anesth Analg 1990; 70: 256–61PubMedCrossRefGoogle Scholar
  14. 14.
    Purdie J, Reid J, Thorburn J, Asbury AJ. Continuous extradural analgesia: comparison of midwife top-ups, continuous infusions and patient controlled administration. Br J Anaesth 1992; 68: 580–4PubMedCrossRefGoogle Scholar
  15. 15.
    Tan S, Reid J, Thorburn J. Extradural analgesia in labour: complications of three techniques of administration. Br J Anaesth 1994; 73: 619–23PubMedCrossRefGoogle Scholar
  16. 16.
    Vandermeulen EP, Van Aken H, Vertommen JD. Labor pain relief using bupivacaine and sufentanil: patient controlled epidural analgesia versus intermittent injections. Eur J Obstet Gynecol Reprod Biol 1995; 59 (suppl.): S47–54PubMedCrossRefGoogle Scholar
  17. 17.
    Paech MJ, Pavy TJG, Sims C, Westmore MD, Storey JM, White C. Clinical experience with patient-controlled and staff-administered intermittent bolus epidural analgesia in labour. Anaesth Intensive Care 1995; 23: 459–63PubMedGoogle Scholar
  18. 18.
    Gambling DR. Epidural infusions in labour should be abandoned in favour of patient-controlled epidural analgesia. International Journal of Obstetric Anesthesia 1996; 5: 59–63PubMedCrossRefGoogle Scholar
  19. 19.
    Gambling DR, White PF. Role of patient-controlled epidural analgesia in obstetrics. Eur J Obstet Gynecol Reprod Biol. 1995; 59: S39–46PubMedCrossRefGoogle Scholar
  20. 20.
    Paech MJ. Patient-controlled epidural analgesia in obstetrics. International Journal of Obstetric Anesthesia 1996: 5: 115–25PubMedCrossRefGoogle Scholar
  21. 21.
    Gambling DR, Yu P, Cole C, McMorland GH, Palmer L. A comparative study of patient-controlled epidural analgesia (PCEA) and continuous infusion epidural analgesia (CIEA) during labour. Can J Anaesth 1988; 35: 249–54PubMedCrossRefGoogle Scholar
  22. 22.
    Ferrante FM, Lu L, Jamison SB, Datta S. Patient-controlled epidural analgesia: demand dosing. Anesth Analg 1991; 73: 547–52PubMedCrossRefGoogle Scholar
  23. 23.
    Ferrante FM, Rosinia FA, Gordon C, Datta S. The role of continuous background infusions in patient-controlled epidural analgesia for labor and delivery. Anesth Analg 1994; 79: 80–4PubMedCrossRefGoogle Scholar
  24. 24.
    Gambling DR, Huber CJ, Berkowitz J et al. Patient-controlled epidural analgesia in labour: varying bolus dose and lock-out interval. Can J Anaesth 1993; 40: 211–7PubMedCrossRefGoogle Scholar
  25. 25.
    Ferrante FM, Barber MJ, Segal M, Hughes NJ, Datta S. 0.0625% bupivacaine with 0.0002% fentanyl via patient-controlled epidural analgesia for pain of labor and delivery. Clin J Pain 1995; 11: 121–6PubMedCrossRefGoogle Scholar
  26. 26.
    Curry PD, Pacsoo C, Heap DG. Patient-controlled epidural analgesia in obstetric anaesthetic practice. Pain 1994; 57: 125–8PubMedCrossRefGoogle Scholar
  27. 27.
    Sia AT, Chong JL. Epidural 0.2% ropivacaine for labour analgesia: parturient-controlled or continuous infusion? Anaesth Intensive Care 1999; 27: 154–8PubMedGoogle Scholar
  28. 28.
    Viscomi C, Eisenach JC. Patient-controlled epidural analgesia during labor. Obstet Gynecol 1991; 77: 348–51PubMedGoogle Scholar
  29. 29.
    Fontenot RJ, Price RL, Henry A, Reisner LS, Weinger MB. Double-blind evaluation of patient-controlled epidural analgesia during labor. International Journal of Obstetric Anesthesia 1993; 2: 73–7PubMedCrossRefGoogle Scholar
  30. 30.
    Riley ET, Ross BK. Epidural and spinal analgesia/anesthesia: Section II, Opioid techniques. In: Chestnut DH (editor). Obstetric Anesthesia, Principles and Practice, 2nd ed. St Louis, Mosby, 1999: p 401Google Scholar
  31. 31.
    Lysak SZ, Eisenach JC, Dobson II CE. Patient-controlled epidural analgesia during labor: a comparison of three solutions with a continuous infusion control. Anesthesiology 1990; 72: 44–9PubMedCrossRefGoogle Scholar
  32. 32.
    Paech MJ. Patient-controlled epidural analgesia during labour: choice of solution. International Journal of Obstetric Anesthesia 1993; 2: 65–72PubMedCrossRefGoogle Scholar
  33. 33.
    Collis RE, Plaat FS, Morgan BM. Comparison of midwife top-ups, continuous infusion and patient-controlled epidural analgesia for maintaining mobility after a low-dose combined spinal-epidural. Br J Anaesth 1999; 82: 233–6PubMedCrossRefGoogle Scholar
  34. 34.
    Owen MD, D’Angelo R, Gerancher JC et al. 0.125% ropivacaine is similar to 0.125% bupivacaine for labor analgesia using patient-controlled epidural infusion. Anesth Analg 1998; 86: 527–31PubMedGoogle Scholar
  35. 35.
    Polley LS, Columb MO, Naughton NN, Wagner DS, van den Ven CJ. Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor: implications for therapeutic indexes. Anesthesiology 1999; 90: 944–50PubMedCrossRefGoogle Scholar
  36. 36.
    Paech MJ. Patient-controlled epidural analgesia in labour - is a continuous infusion of benefit? Anaesth Intensive Care 1992; 20: 15–20PubMedGoogle Scholar
  37. 37.
    White PF, Gambling DR, Parker RK. Role of continuous background infusion with epidural patient-controlled analgesia (letter). Anesth Analg 1995; 80: 646–7PubMedGoogle Scholar
  38. 38.
    Paech MJ. Epidural analgesia in labour: constant infusion plus patient-controlled boluses. Anaesth Intensive Care 1991; 19: 32–9PubMedGoogle Scholar
  39. 39.
    Bush DJ, Kramer DP. Intravascular migration of an epidural catheter during patient-controlled epidural analgesia. Anesth Analg 1993; 76: 1150–1PubMedCrossRefGoogle Scholar
  40. 40.
    Kaynar AM, Shankar KB. Epidural infusion: Continuous or Bolus? Anesth Analg 1999; 89: 534 (letter)Google Scholar
  41. 41.
    Eisenach JC. Patient controlled epidural analgesia during labor, or whose finger do you want on the button? International Journal of Obstetric Anesthesia 1993; 2: 63–4PubMedCrossRefGoogle Scholar
  42. 42.
    Lurie S. Patient-controlled epidural analgesia during labor may be hazardous. Anesthesiology 1990; 73: 789. (letter)Google Scholar

Copyright information

© Springer-Verlag London 2000

Authors and Affiliations

  • David R. Gambling

There are no affiliations available

Personalised recommendations