Abstract
A high resolution grating spectrometer (HRGS) with 2400 line/mm variable line spacing grating for the 10 – 50 Å wavelength range has been designed for laser—produced plasma experiments at the Lawrence Livermore National Laboratory (LLNL). The spectrometer has a large radius of curvature, R=44.3 m, is operated at a 2° grazing angle and can record high signal-to-noise spectra when used with a low-noise, cooled, charge-coupled device detector. The instrument can be operated with a 10 – 25 μm wide slit to achieve the best spectral resolving power on laser plasma sources, approaching 2000, or in slitless mode with a small symmetrical emission source. Results will be presented for the spectral response of the spectrometer cross-calibrated at the LLNL Electron Beam Ion Trap facility using the broadband x-ray energy EBIT Calorimeter Spectrometer (ECS).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J. Dunn, E.W. Magee, R. Shepherd, H. Chen, S.B. Hansen, S.J. Moon, G.V. Brown, M.-F. Gu, and P. Beiersdorfer, and M.A. Purvis, “High resolution soft x-ray spectroscopy of low Z K-shell emission from laser-produced plasmas”, accepted for publication in Rev. Sci. Instrum. (2008).
H.R. Griem, “Plasma Spectroscopy”, (McGraw-Hill, New York, 1964).
C. De Michelis and M. Mattioli, “Soft-x-ray spectroscopic diagnostics of laboratory plasmas”, Nucl. Fus. 21(6), 677 (1981).
A. Saemann and K. Eidmann, “Absolute calibration of a flat field spectrometer in the wavelength range 10–70 Å”. Rev. Sci. Instrum. 69, 1949 (1998).
F.S. Porter, B.R. Beck, P. Beiersdorfer, K.R. Boyce, G.V. Brown, H. Chen, J. Gygax, S.M. Kahn, R.L. Kelley, C.A. Kilbourne, E. Magee, and D.B. Thorn, “The XRS microcalorimeter spectrometer at the Livermore electron beam ion trap”, Can. J. Phys. 86, 231 (2008).
G.V. Brown, P. Beiersdorfer, J. Emig, M. Frankel, M.F. Gu, R.F. Heeter, E. Magee, D.B. Thorn, K. Widmann, R.L. Kelley, C.A. Kilbourne, and F.S. Porter, “Rapid, Absolute Calibration of X-ray Filters Employed By Laser-Produced Plasma Diagnostics”, accepted for publication in Rev. Sci. Instrum. (2008).
P. Beiersdorfer, “A “brief” history of spectroscopy on EBIT”, Can. J. Phys. 86(1), 1–10 (2008); More references and work on EBIT can be found in this volume.
P. Beiersdorfer, E.W. Magee, E. Träbert, H. Chen, J.K. Lepson, M.-F. Gu, and M. Schmidt, “Flat-field grating spectrometer for high-resolution soft x-ray and extreme ultraviolet measurements on an electron beam ion trap”, Rev. Sci. Instrum. 75, 3723 (2004).
Theoretical filter transmission obtained from the Lawrence Berkeley National Laboratory website at http://www-cxro.lbl.gov/
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer
About this paper
Cite this paper
Dunn, J., Beiersdorfer, P., Brown, G.V., Magee, E.W. (2009). Calibration of a High Resolution Soft X-Ray Spectrometer. In: Lewis, C.L.S., Riley, D. (eds) X-Ray Lasers 2008. Springer Proceedings in Physics, vol 130. Springer, Dordrecht. https://doi.org/10.1007/978-1-4020-9924-3_54
Download citation
DOI: https://doi.org/10.1007/978-1-4020-9924-3_54
Publisher Name: Springer, Dordrecht
Print ISBN: 978-1-4020-9923-6
Online ISBN: 978-1-4020-9924-3
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)