Abstract
For many hundreds of years, physicians have gained information on cardiac function by feeling movements of the heart through the chest wall. They learned to distinguish the barely palpable stirring of the normal heart from the hyperdynamic action which accompanies increased output; the powerful sustained thrust of the hypertrophied heart which is working against a raised resistance; and the labouring heave of the failing myocardium, which has exhausted its powers of compensation and is progressively dilating. Indeed, prior to the development of electrocardiography at the beginning of this century, and catheterisation of the heart thirty years later, palpation of the precordial impulse, inspection of the jugular veins, and auscultation of the heart sounds completed the cardiologist’s diagnostic equipment.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Agress, C. M. and Fields, L. G. 1959: A new method for analysing heart vibrations. Amer. J. Cardiol. 4: 184.
Chaveau, P. 1861: Determination graphique des rapports de la pulsation cardiaque avec les mouvements de l’oriellette et due ventricule, obtenue au moyen d’un appareil en registrant. Gaz. Med. (Paris) 31: 675.
Cohn, P. F., Vokanas, P. S., Williams, R. A., Herman, M. V., and Gorlin, R. 1971: Diastolic heart sounds and filling waves in coronary artery disease. Circ. 44: 196.
Coulshed, N., and Epstein, E. J. 1963: The apex cardiogram. Brit. Heart J. 25: 697.
Dimond, E. G., Duenas, A., and Benchimol, A. 1966: Apex cardiography. Amer. Heart J. 72: 124.
Dodge, H. T., Sandler, H., Ballew, D. W., et al. 1960: The use of biplane angiocardiography for the measurement of L.V. volume in man. Amer. Heart J. 60: 762.
Eddleman, E. E., Willis, K., Reeves, T. J. et al. 1953: Kinetocardiogram: I. Method of recording precordial movements. Circ. 8:269.
Eddleman, E. E. 1965: The Kinetocardiogram. In ‘Examination of the Cardiac Patient’ (Ed. A. A. Luisada ). McGraw-Hill, London and New York.
Gleichmann, U., Kreuzer, H., Loggen, F. et al. 1968: Quantitative measurement of the force and of the rate of development of force in the apex cardiogram. Z. Ges. Exp. Med. 145: 278.
Ingue, K. et al. 1971: Ultrasonic measurement of left ventricular wall motion in acute myocardial infarction. Circ. 43, 778.
Kumar, S., and Spodick, D. H. 1970: Study of the mechanical events of the left ventricle by atraumatic techniques. Amer. Heart J. 80: 401.
Lane, F. J., Carroll, J. M., Levine, H. D., and Gorlin, R. 1968: The apex cardiogram in myocardial asynergy. Circ. 37: 890.
Mcginn, F. X., and Lyon, A. 1968: The phonocardiogram and apexcardiogram in patients with ventricular aneurysms. Amer. J. Cardiol. 21: 467.
Miller, G. A. H., Kirklin, J. W., and Swan, J. H. C. 1965: Myocardial function and left ventricular volumes in acquired valvular insufficiency. Circ. 31: 374.
Share, M. et al. (1970). A new electronic technique for indirect reading of maternal blood flow in the placenta and its localization. Amer. J. Obst. Gynec. 106: 292.
Suis, S. K. and Eddleman, E. E. Jr. 1959: Kinetocardiographic findings of myocardial infarction. Circ. 19: 531.
Sutton, G. C., Prewirr, T. A., and Craige, E. 1970: Relationship between quantitated precordial movement and L.V. function. Circ. 41: 179.
Tavel, M. E. et al. 1965: The apex cardiogram and its relationship to haemodynamic events within the left heart. Brit. Heart J. 27: 829.
Valero, A. (1967). Recording actual heart movements and arterial pulsations with a new electronic device. Amer. J. Cardiol. 19: 224.
Valero, A., and Vas, R. 1969: On the displacement cardiograph in normal subjects and some pathologic cases. Haraguah J, Israel Med. Assoc.
Valero, A., Peleg, H., and Molcxo, J. 1969: Focal cardiography. An experimental study in dogs. Israel J. Med. Sci. 5: 13.
Vas, R. 1967: Electronic device for physiological kinetic measurement and detection of extraneous bodies. I.E.E.E. Trans. BioMed. Eng., BME 14: 2.
Voigt, G. C. and Friesinger, G. C. 1970: The use of apexcardiography in the assessment of L.V. diastolic pressure. Circ. 41: 1015.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Copyright information
© 1973 Bioengineering Unit, University of Strathclyde
About this chapter
Cite this chapter
Bain, W.H., Grassie, T.G., Fenton, T.R., Vas, R., Thevoz, F., Bain, W.H. (1973). Kinetography and Its Application in Heart Studies. In: Kenedi, R.M. (eds) Perspectives in Biomedical Engineering. Palgrave Macmillan, London. https://doi.org/10.1007/978-1-349-01604-4_37
Download citation
DOI: https://doi.org/10.1007/978-1-349-01604-4_37
Publisher Name: Palgrave Macmillan, London
Print ISBN: 978-1-349-01606-8
Online ISBN: 978-1-349-01604-4
eBook Packages: EngineeringEngineering (R0)