The Hardware Research of Dual-port RAM for Main-spare CPU in Rural Power Terminal System of Power Quantity Collection

  • Ping Yang
  • Shu Dai
  • Xiuhua Wu
  • Yong Yang
Part of the The International Federation for Information Processing book series (IFIPAICT, volume 258)

With the development of rural power market in our country, how to improve the operation more correctly and timely of power quantity collection, transmission and processing becomes a problem. The requirement of equipment in power quantity collection needs new and higher demands. The advantage of using dual-port RAM and main-spare CPU structure, when main CPU running, spare CPU supply monitoring of main CPU status messages, once main CPU break down, spare CPU could instead of main CPU completely. This paper introduces collectivity design in flow chart, hardware design include theory and application in detail. Using dual-port RAM to communicate between the main and spare CPU not only make sure the transmission efficiency, good anti-jamming performance, improve the speed of disposal, but also reduce the costs, making the operation of rural power network more security, economy and reliability. In rural power terminal system of power quantity collection has broad application prospects.

Keywords

dual-port RAM main-spare CPU terminal of power quantity collection parallel communication data exchange 

References

  1. Chen Deming, Xiong Liebin, Application of Dual RAM in Automation System, International Electronic Elements, 2005, No. 4, pp. 20-23.Google Scholar
  2. Cypress Semiconductor Corporation, Interfacing the CY7C028V with Motorola’s MPC860 Power QUICCTM Processor, 2002.Google Scholar
  3. Cypress Semiconductor Corporation, 3.3V 64K×16 Dual Port Static RAM CY7C028V Data Sheet, 2004.Google Scholar
  4. Deng Xiaogang, Xu Shiming, Tang Houjun, New Type of Power Amount Acquisition Terminal Based on Insert-style System, North China Electric Power, 2005, No. 11, pp. 42-45.Google Scholar
  5. Huang Bin, Hu Rongqiang, Meng Qinghong, Design and Implementation of Real-Time Supervisory System Based on Dual CPU, Journal of WUT (Information & Management Engineering), 2004, Vol. 26, No. 2, pp. 45-48.Google Scholar
  6. Ji Qiang, Liu Liqiang, Application of Dual-port RAM to Data-acquisition System, Applied Science and Technology, 2004, Vol. 31, No. 5, pp. 22-24.Google Scholar
  7. Jia Guixi, Qi Le, Design of Data Supervision System Based on Dual CPU Structure, Engineering Science, 2006, No. 4, pp. 68-71.Google Scholar
  8. Li Xiaoqing, The Application of Dual-Port RAM in the Computer Measurement and Control System of Multi-cpu, Control & Automation, Vol. 15, No. 1, 1999, pp. 54-56.Google Scholar
  9. Li Yufeng, Design of Two Monolithic Computers Parallel Communication System Based on Dual-port RAM, J. Changchun Inst. Tech. (Nat. Sci. Edi.), 2001, Vol. 2, No. 3, pp. 56-58.Google Scholar
  10. Liu Xin, Yin Zhiqiang, Mu Guobao, Ma Shidian, Research on Parallel Communication Based on Dual-port RAM in the Noncompetitive Pattern, Journal of Hefei University of Technology, 2006, Vol. 29, No. 2, pp. 234-237.Google Scholar
  11. Mladen Kezunovic,Yuan Liao, A New Method for Classification and Characterization of Voltages Sags. Electric Power Systems Research, 2001, Vol. 58, No. 1, pp. 27-35.CrossRefGoogle Scholar
  12. National Instrument, A New Open Specification for Modular Instrumentation, 1997.Google Scholar
  13. National Instrument, The PXI System Architecture, 1997.Google Scholar
  14. State Economic and Trade Commission, Terminal System of Electrical Energy Collecting for Electric Power Industry, China Electric Power Press, 2001.Google Scholar
  15. Ti Zhaoxu, Li Yuan, Design and Optimization Study of MIS of A Large Power Supply Bureau Client/Server System Being Used Successfully in Guangzhou Power Supply Bureau, Proceedings of the CSEE, 1999, Vol. 19, No. 5, pp. 85-88.Google Scholar
  16. Tang lei, Zhang Boming, Sun hongbin, A Processing Method of Real-time Data in Energy Management System, Power System Technology, 2001, No. 5, pp. 15-19.Google Scholar
  17. Wang Jing, Ji Xinsheng, Zhu Yunzhi, Strategies of Improving the High Usability of Application Software on Embedded OS, Control & Automation, Vol. 21, No. 82, 2005, pp. 42-44.Google Scholar
  18. Wang Junliang, Yuan Yijiang, Zhang Jiang, The Design and Application of Electric Energy Acquisition Terminal Based on GSM Communication, Journal of Henan Mechanical and Electrical Engineering College, Vol. 12, No. 2, 2004, pp. 42-44.Google Scholar

Copyright information

© IFIP International Federation for Information Processing 2008

Authors and Affiliations

  • Ping Yang
    • 1
  • Shu Dai
    • 2
  • Xiuhua Wu
    • 1
  • Yong Yang
    • 1
  1. 1.Agricultural Information InstituteThe Chinese Academy of Agricultural SciencesChina
  2. 2.Anshan Electricity Power BureauChina

Personalised recommendations