In 1973, Dr. Paul C. Lauterbur published his seminal article on using magnetic field gradients to resolve the sources of nuclear magnetic resonance (NMR) signals into pixels or voxels.1 Most physicists at the time believed this to be impossible, due to the general principle that spatial resolution is limited by the wavelength of the electromagnetic radiation used as a probe. At a magnetic field strength of 1 Tesla, the wavelength of electromagnetic radiation that excites hydrogen nuclei is 7 meters (3 × 108 meters/second/(42.6 × 106 1/seconds) = 7.04 meters), which would make studying details in the human body impossible. Lauterbur correctly recognized and demonstrated that this limitation, while applying to scattering experiments, was cleverly overcome by using magnetic field gradients to localize signals in NMR. He called his new technique “zeugmatography”. Until the early 1980s, most researchers favored the name “NMR imaging”. The “nuclear” in NMR imaging was dropped when whole-body scanners became clinically available in the early 1980s. This was done to avoid adverse reactions from the public about potential association with “nuclear” imaging and its associated radiation effects. Paul Lauterbur shared the 2003 Nobel Prize in medicine for his invention of MRI.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance”, Nature 1973; 242: 190–191.
Hendrick RE, Osborn A, Kanal E. Basic MRI physics. In Kressel H, Modic M, Murphy W. Syllabus: Special Course - MR 1990. RSNA Publications, Chicago, IL, 1990, pp. 7–30.
Matwiyoff NA, Brooks WM. Instrumentation. In Magnetic Resonance Imaging, 3rd Edition. Eds DD Stark and WG Bradley. St. Louis: Mosby Publishing Co., 1999. Volume 1, Ch. 2, p. 15–32.
Wood ML, Wehrli FW (1999) Principles of magnetic resonance imaging. In Magnetic Resonance Imaging, 3rd Edition. Eds DD Stark and WG Bradley. St. Louis: Mosby Publishing Co., 1999. Volume 1, Ch. 1, p. 1–14.
Hendrick RE. Image contrast and noise. In Stark DD, Bradley WG. Magnetic Resonance Imaging, 3rd Edition. St. Louis: Mosby Publishing Co., 1999, Vol 1, Ch 4, 43–68.
Sachs TS, Meyer CH, Hu BS, et. al. Real-time motion detection in spiral MRI using navigators. Magn Reson Med. 1994; 32: 639–45.
Frahm J, Haenicke W. Rapid scan techniques. In Stark DD, Bradley WG. Magnetic Resonance Imaging, 3rd Edition. St. Louis: Mosby Publishing Co., 1999, Vol 1, Ch 6, 87–124.
Perman WH, Heiberg EV, Herrmann VM. Half-Fourier, three-dimensional technique for dynamic contrast-enhanced MR imaging of both breasts and axillae: initial characterization of breast lesions. Radiology 1996; 200: 263–269.
Rights and permissions
Copyright information
© 2008 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
(2008). Spatial Resolution in Magnetic Resonance Imaging. In: Breast MRI. Springer, New York, NY. https://doi.org/10.1007/978-0-387-73507-8_3
Download citation
DOI: https://doi.org/10.1007/978-0-387-73507-8_3
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-73506-1
Online ISBN: 978-0-387-73507-8
eBook Packages: MedicineMedicine (R0)