In conclusion, a stent-graft is a more efficient and safer modality for the treatment of aortic dissection than any other current treatment modality, having 87% success rate and 0% mortality. However, various problems and complications could occur during the procedure and the follow-up period. Careful design of the stent-graft, the procedure itself and close follow-up are mandatory for the avoidance and prompt management of such problems.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 119.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 159.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bortone AS, Cillis ED, D’Agostino D, Schinosa LL (2004) Endovascular treatment of thoracic aortic disease four years of experience. Circulation 110(Suppl):II262–II267.

    Article  PubMed  Google Scholar 

  2. Cambria RP, Brewster DC, Lautebach SR, Kaufman JL, Geller S, Fan CM, Greenfield A, Hilgenberg A, Clouse WD (2002) Evolving experience with thoracic aortic stent graft repair. J Vase Surg 35:1129–1136.

    Article  Google Scholar 

  3. Czermak BV, Waldenberger P, Fraedrich G, Dessl AH, Roberts KE, Bale RJ, Perkmann R, Jaschke WR (2000) Treatment of Stanford type B aortic dissection with stent-grafts: preliminary results. Radiology 217:544–550.

    PubMed  CAS  Google Scholar 

  4. Czermak BV, Waldenberger P, Perkmann R, Rieger M, Steingruber IE, Mallouhi A, Fraedrich G, Jaschke WR (2002) Placement of endovascular stent-grafts for emergency treatment of acute disease of the descending thoracic aorta. Am J Roentgenol 179:337–345.

    Google Scholar 

  5. Dake MD, Kato N, Mitchell RS, Semba CP (1999) Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 340:1546–1552.

    Article  PubMed  CAS  Google Scholar 

  6. DeSanctis RW, Doroghazi RM, Austen WG, Buckley MJ (1987) Aortic dissection. N Engl J Med 317:1060–1067.

    Article  PubMed  CAS  Google Scholar 

  7. Dinis da Gama A (1991) The surgical management of aortic dissection: from uniformity to diversity, a continuous challenge. J Cardiovasc Surg 32:141–153.

    CAS  Google Scholar 

  8. Dinsmore RE, Willerson JT, Buckley MJ (1972) Dissecting aneurysm of the aorta: aortographic features affecting prognosis. Radiology 105:567–572.

    PubMed  CAS  Google Scholar 

  9. Fann JI, Miller DC (1995) Aortic dissection. Ann Vase Surg 9:311–323.

    Article  CAS  Google Scholar 

  10. Gorich J, Asquan Y, Seifarth H (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9(Suppl):II39–II43.

    Article  PubMed  Google Scholar 

  11. Grabenwoeger M, Hutschala D, Marek PE, Cartes-Zumelzu F, Thurnher S, Lammer J, Wolner E, Havel M (2000) Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts. Ann Thorac Surg 69:441–445.

    Article  Google Scholar 

  12. Hutschala D, Fleck T, Czerny M, Ehrlich M, Schoder M, Lammer J, Wolner E, Grabenwoger M (2002) Endoluminal stent-graft placement in patients with acute aortic dissection type B. Eur J Cardiothorac Surg 21:964–969.

    Article  PubMed  CAS  Google Scholar 

  13. Jacobs TS, Won J, Gravereaux EC, Faries PL, Morrissey N, Teodorescu VJ, Hollier LH, Marin ML (2003) Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices. J Vase Surg 37:16–26.

    Article  Google Scholar 

  14. Kang SG, Lee DY, Maeda M, Kim ES, Choi DH, K BO, Yoon HK, Sung KB, Song HY (2001) Aortic dissection: percutaneous management with a separating stent-graft — preliminary results. Radiology 220:533–539.

    PubMed  CAS  Google Scholar 

  15. Kato N, Hirano T, Kawaguchi T, Ishida M, Shimono T, Yada I, Takeda K (2001) Aneurysmal degeneration of the aorta after stentgraft repair of acute aortic dissection. J Vase Surg 34:513–518.

    Article  CAS  Google Scholar 

  16. Kato N, Shimono T, Hirano T, Suzuki T, Ishida M, Sakuma H, Yada I, Takeda K (2002) Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: The complication-specific approach. J Thorac Cardiovasc Surg 124:306–312.

    Article  PubMed  Google Scholar 

  17. Lawler LP, Fishman EK (2003) Multidetector row computed tomography of the aorta and peripheral arteries (review). Cardiol Clin 21:607–629.

    Article  PubMed  Google Scholar 

  18. Lepore V, Lonn L, Delle M, Bugge M, Jeppsson A, Kjellman U, Radberg G, Risberg B (2002) Endograft therapy for diseases of the descending thoracic aorta: results in 43 high-risk patients. J Endovasc Ther 9:829–837.

    Article  PubMed  Google Scholar 

  19. Lonn L, Delle M, Falkenberg, Lepore V, Klingenstierna H, Radberg G, Risberg B (2003) Endovascular Treatment of Type B Thoracic Aortic Dissections. J Card Surg 18:539–544.

    Article  PubMed  Google Scholar 

  20. Lopera J, Patiño JH, Urbina C, Garcia G, Alvarez LG, Upegui L, Jhanchai A, Qian Z, Castaneda-Zuniga W (2003) Endovascular treatment of complicated type-B aortic dissection with stent-grafts: midterm results. J Vase Interv Radiol 14:195–203.

    Google Scholar 

  21. Mackenzie KS, LeGuillan M, Steinmetz OK, Montreuil B (2004) Management trends and early mortality rates for acute type B aortic dissection: a 10-year single-institution experience. Ann Vase Surg 18:158–166.

    Article  Google Scholar 

  22. Marui A, Mochizuki T, Mitsui N (1999) Toward the best treatment for uncomplicated patients with type B acute aortic dissection: a consideration for sound surgical indication. Circulation 100(Suppl):II275–II280.

    PubMed  CAS  Google Scholar 

  23. Mitchell RS, Dake MD, Semba CP, Fogarty TJ, Zarins CK, Liddell BA, Miller C (1996) Endovascular stent-graft repair of thoracic aortic aneurysms. J Thorac Cardiovasc Surg 111:1054–1062.

    Article  PubMed  CAS  Google Scholar 

  24. Nienaber CA, Eagle KA (2003) Aortic dissection: new frontiers in diagnosis and management. Circulation 108:628–635.

    Article  PubMed  Google Scholar 

  25. Palma JH, Souza JAM, Alves CMR, Carvalho AC, Buffolo E (2002) Self-expandable aortic stent-grafts for treatment of descending aortic dissections. Ann Thorac Surg 73:1138–1142.

    Article  PubMed  Google Scholar 

  26. Pamler RS, Kotsis T, Görich J, Kapfer X, Orend KH, Plassmann LS (2002) Complications after endovascular repair of type B aortic dissection. J Endovasc Ther 9:822–828.

    Article  PubMed  Google Scholar 

  27. Prendergast BD, Boon NA, Buckenham T (2002) Aortic dissection: advances in imaging and endoluminal repair. Cardiovasc Interv Radiol 25:85–97.

    Article  Google Scholar 

  28. Quinn SF, Duke DJ, Baldwin SS, Bascom TH, Ruff SJ, Swangard RJ, DeHaas DR, Padgett RC, Bergin PJ, Lau S (2002) Percutaneous placement of a low-profile stent-graft device for aortic dissections. J Vase Interv Radiol 13:791–798.

    Google Scholar 

  29. Resch T, Ivancev K, Brunkwall J, Nyman U, Malina M, Lindblad B (1999) Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. J Vase Interv Radiol 10:257–264.

    Article  CAS  Google Scholar 

  30. Ryan JM, Ryan BM, Smith TP (2004) Antibiotic prophylaxis in interventional radiology. J Vase Interv Radiol 15:547–556.

    Google Scholar 

  31. Schor JS, Yerlioglu ME, Galla JD, Lansman SL, Ergin MA, Griepp RB (1996) Selective management of acute type B aortic dissection: longterm follow-up. Ann Thorac Surg 61:1339–1341.

    Article  PubMed  CAS  Google Scholar 

  32. Schurink GW, Aarts NJ, van Baalen JM, Kool LJS, van Bockel JH (1999) Stent attachment site-related endoleakage after stent graft treatment: An in vitro study of the effects of graft size, stent type, and atherosclerotic wall changes. J Vase Surg 30:658–667.

    Article  CAS  Google Scholar 

  33. Shimono T, Kato N, Yasuda F, Suzuki T, Yuasa U, Onoda K, Hirano T, Takeda K, Yada I (2002) Transluminal Stent-Graft Placements for the Treatments of Acute Onset and Chronic Aortic Dissections. Circulation 106(Suppl):I241–I247.

    PubMed  Google Scholar 

  34. Svensson LG, Crawford ES, Hess KR, Coselli JS, Safi HJ (1993) Variables predictive of outcome in 832 patients undergoing repairs of the descending thoracic aorta. Chest 104:1248–1253.

    PubMed  CAS  Google Scholar 

  35. Veerapen R, Dorandeu A, Serre I, Berthet JP, Marty-Ane CH, Mary H, Alric P (2003) Improvement in proximal aortic endograft fixation: an experimental study using different stent-grafts in human cadaveric aortas. J Endovasc Ther 10:1101–1109.

    Article  PubMed  Google Scholar 

  36. Velazquez OC, Carpenter JP, Baum RA, Barker CF, Golden M, Criado F, Pyeron A, Fairman RM (1999) Perigraft air, fever and leukocytosis after endovascular repair of abdominal aortic aneurysms. Am J Surg 178:185–189.

    Article  PubMed  CAS  Google Scholar 

  37. Won JY, Lee DY, Shim WH, Chang BC, Park SI, Yoon CS, Kwon HM, Park BH, Jung GS (2001) Elective endovascular treatment of descending thoracic aortic aneurysms and chronic dissections with stent-grafts. J Vase Interv Radiol 12:575–582.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2006 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Won, J.Y., Lee, D.Y. (2006). Problems Encountered During and After Stent-Graft Treatment of Aortic Dissection. In: Rousseau, H., Verhoye, JP., Heautot, JF. (eds) Thoracic Aortic Diseases. Springer, Berlin, Heidelberg . https://doi.org/10.1007/3-540-38309-3_21

Download citation

  • DOI: https://doi.org/10.1007/3-540-38309-3_21

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-25734-9

  • Online ISBN: 978-3-540-38309-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics