Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP (1998) Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 71:135–140
Deichen JT, Detmar K, Oldendorf M, Loose RWR (2000) Multislice CT: image quality of primary coronal acquired images compared with secondary reformatted coronal images of primary axial acquired data. Eur Radiol 10(Suppl 1):189
Flohr T, Stierstorfer K, Bruder H, Simon J, Schaller S (2002a) New technical developments in multislice CT. Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning. Fortschr Röntgenstr 174:839–845
Flohr T, Bruder H, Stierstorfer K, Simon J, Schaller S, Ohnesorge B (2002b) New technical developments in multislice CT. Part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Fortschr Röntgenstr 174:1022–1027
Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46:1016–1022
Hu H, He HD, Foley WD, Fox SH (2000) Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 215:55–62
Kalender W (1995) Thin-section three-dimensional spiral CT: Is isotropic imaging possible? Radiology 197:578–580
Kalender WA, Vock P, Polacin A, Soucek M (1990) Spiral-CT: a new technique for volumetric scans. I. Basic principles and methodology. Rontgenpraxis 43:323–330
Klingenbeck-Regn K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol 31:110–124
Loose R, Oldendorf M, Deichen JT, Wucherer M (2000) Management des Datenvolumens von Multizeilen-CT-Scannern. Fortschr Röntgenstr 172:133
Nagel HD (2000) Factors influencing patient dose in CT. In: Nagel HD (ed) Radiation exposure in computed tomography. COCIR c/o ZVEI Fachverband Elektromedizinische Technik, pp 25–43
Ohnesorge B, Flohr T, Schaller S, Klingenbeck-Regn K, Becker C, Schöpf UJ, Brüning R, Reiser MF (1999) Technische Grundlagen und Anwendungen der Mehrschicht-CT. Radiologe 39:923–931
Oldendorf M, Loose R, Wucherer M (2000) Mehrzeilen Spiral-CT des Thorax. Neue Scanprotokolle und sekundäre Nachverarbeitungstechniken. Fortschr Röntgenstr 172:18
Schaller S, Wildberger JE, Raupach R, Niethammer M, Klingenbeck-Regn K, Flohr T (in press) Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography. IEEE Trans Med Imaging
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Loose, R., Schaller, S., Oldendorf, M. (2006). Workflow Design for MDCT of the Thorax. In: Joseph Schoepf, U. (eds) Multidetector-Row CT of the Thorax. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-30006-6_23
Download citation
DOI: https://doi.org/10.1007/3-540-30006-6_23
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-26247-3
Online ISBN: 978-3-540-30006-9
eBook Packages: Springer Book Archive