Summary
The evolution of knee implant design reflects recognition of the principle that implant geometry, acting in concert with surrounding soft-tissue structures,determines joint stability, range of motion, interface forces, and material stresses. Interchangeable plateau geometries associated with modular knee designs permit the orthopedic surgeon to optimize the articulation for a patient’s presenting pathology within a single system. This chapter presents performance characteristics for contemporary knee designs including intrinsic stability and surface stress distributions.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bohl JR et al (1999) The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components. Clin Orthop 267:28–38
Busanelli L et al (1996) Wear in carbon fiber-reinforced polyethylene (poly-two) knee prostheses. Chir Organi Mov 81:263–267
Wright TM et al (1992) Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. Clin Orthop 276:126–134
Collier JP et al (1991) Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273:232–242
Peters PC et al (1992) Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg [Am] 74:864–876
Greenwald AS et al (1981) Total knee replacement. American Academy of Orthopedic Surgeons Instructional Course Lectures 30:301–312
Heim CS et al (1996) Stability characteristics of Posterior Stabilized Total Knee Systems. Scientific Exhibit at the 63rd Annual Meeting of the American Academy of Orthopedic Surgeons
Postak PD et al (1991) Performance characteristics of modular total knee systems. Scientific Exhibit at the 58th Annual Meeting of the American Academy of Orthopedic Surgeons
Postak PD et al (1992) Performance characteristics of primary modular total knee systems. Scientific Exhibit at the 59th Annual Meeting of the American Academy of Orthopedic Surgeons
Morrison JB (1969) Function of the knee joint in various activities. Biomed Eng 4:573–580
Heim CM et al (1996) Factors influencing the longevity of UHMWPE tibial components. American Academy of Orthopedic Surgeons Instructional Course Lectures 45:303–314
Berger RA et al (2001) Problems with cementless total knee arthroplasty at 11 years follow-up. Clin Orthop 392:196–207
Engh GA et al (1994) Tibial osteolysis in cementless total knee arthroplasty. A review of 25 cases treated with and without tibial component revision. Clin Orthop 309:33–43
Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomech 3:51–61
Seireg A et al (1975) The prediction of muscular load sharing and joint forces in the lower extremities during walking. J Biomech 8:89–102
Bartel DL et al (1985) The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 107:193–199
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Medizin Verlag Heidelberg
About this chapter
Cite this chapter
Greenwald, A.S., Heim, C.S. (2005). Modular UHMWPE Insert Design Characteristics. In: Bellemans, J., Ries, M.D., Victor, J.M. (eds) Total Knee Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-27658-0_58
Download citation
DOI: https://doi.org/10.1007/3-540-27658-0_58
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-20242-4
Online ISBN: 978-3-540-27658-6
eBook Packages: MedicineMedicine (R0)