Skip to main content

Modular UHMWPE Insert Design Characteristics

  • Chapter
Total Knee Arthroplasty
  • 3194 Accesses

Summary

The evolution of knee implant design reflects recognition of the principle that implant geometry, acting in concert with surrounding soft-tissue structures,determines joint stability, range of motion, interface forces, and material stresses. Interchangeable plateau geometries associated with modular knee designs permit the orthopedic surgeon to optimize the articulation for a patient’s presenting pathology within a single system. This chapter presents performance characteristics for contemporary knee designs including intrinsic stability and surface stress distributions.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bohl JR et al (1999) The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components. Clin Orthop 267:28–38

    Article  Google Scholar 

  2. Busanelli L et al (1996) Wear in carbon fiber-reinforced polyethylene (poly-two) knee prostheses. Chir Organi Mov 81:263–267

    PubMed  Google Scholar 

  3. Wright TM et al (1992) Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. Clin Orthop 276:126–134

    PubMed  Google Scholar 

  4. Collier JP et al (1991) Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273:232–242

    PubMed  Google Scholar 

  5. Peters PC et al (1992) Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg [Am] 74:864–876

    PubMed  Google Scholar 

  6. Greenwald AS et al (1981) Total knee replacement. American Academy of Orthopedic Surgeons Instructional Course Lectures 30:301–312

    Google Scholar 

  7. Heim CS et al (1996) Stability characteristics of Posterior Stabilized Total Knee Systems. Scientific Exhibit at the 63rd Annual Meeting of the American Academy of Orthopedic Surgeons

    Google Scholar 

  8. Postak PD et al (1991) Performance characteristics of modular total knee systems. Scientific Exhibit at the 58th Annual Meeting of the American Academy of Orthopedic Surgeons

    Google Scholar 

  9. Postak PD et al (1992) Performance characteristics of primary modular total knee systems. Scientific Exhibit at the 59th Annual Meeting of the American Academy of Orthopedic Surgeons

    Google Scholar 

  10. Morrison JB (1969) Function of the knee joint in various activities. Biomed Eng 4:573–580

    PubMed  Google Scholar 

  11. Heim CM et al (1996) Factors influencing the longevity of UHMWPE tibial components. American Academy of Orthopedic Surgeons Instructional Course Lectures 45:303–314

    Google Scholar 

  12. Berger RA et al (2001) Problems with cementless total knee arthroplasty at 11 years follow-up. Clin Orthop 392:196–207

    PubMed  Google Scholar 

  13. Engh GA et al (1994) Tibial osteolysis in cementless total knee arthroplasty. A review of 25 cases treated with and without tibial component revision. Clin Orthop 309:33–43

    PubMed  Google Scholar 

  14. Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomech 3:51–61

    Article  PubMed  Google Scholar 

  15. Seireg A et al (1975) The prediction of muscular load sharing and joint forces in the lower extremities during walking. J Biomech 8:89–102

    Article  PubMed  Google Scholar 

  16. Bartel DL et al (1985) The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 107:193–199

    PubMed  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer Medizin Verlag Heidelberg

About this chapter

Cite this chapter

Greenwald, A.S., Heim, C.S. (2005). Modular UHMWPE Insert Design Characteristics. In: Bellemans, J., Ries, M.D., Victor, J.M. (eds) Total Knee Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-27658-0_58

Download citation

  • DOI: https://doi.org/10.1007/3-540-27658-0_58

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-20242-4

  • Online ISBN: 978-3-540-27658-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics