Advertisement

The Pupil and Refractive Surgery

  • Emanuel Rosen
Part of the Essentials in Ophthalmology book series (ESSENTIALS)

Keywords

Pupil Size Pupil Diameter Refractive Surgery Entrance Pupil Optical Zone 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Boxer Wachler BS (2003) Effect of pupil size on visual function under monocular and binocular conditions in LASIK and non-LASIK patients. J Cataract Refract Surg 29:275–279PubMedCrossRefGoogle Scholar
  2. 2.
    Brint S (2003) The effect of pupil size on night visual disturbances after LASIK. Presentation at the AAO Anaheim, NovemberGoogle Scholar
  3. 3.
    Ettinger ER, Wyatt HJ, London R (1991) Anisocoria. Variation and clinical observation with different conditions of illumination and accommodation. Invest Ophthalmol Vis Sci 32:501–509PubMedGoogle Scholar
  4. 4.
    Freedman KA, Brown SM, Mathews SM, Young RS (2003) Pupil size and the ablation zone in laser refractive surgery: considerations based on geometric optics. J Cataract Refract Surg 29:1924–1931PubMedCrossRefGoogle Scholar
  5. 5.
    Holladay JT, Janes JA (2002) Topographic changes in. corneal asphericity and effective optical zone after laser in situ keratomileusis. J Cataract Refract Surg 28:942–947PubMedGoogle Scholar
  6. 6.
    Kohnen T, Terzi E, Buhren J, Kohnen EM (2003) Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter. J Cataract Refract Surg 29:112–117PubMedGoogle Scholar
  7. 7.
    Loewenfeld IE (1999) The pupil. Butterworth Heinemann, Oxford, UKGoogle Scholar
  8. 8.
    Pop M, Payette Y (2004) Risk factors for night vision disturbances after LASIK for myopia. Ophthalmology 111:3–10PubMedGoogle Scholar
  9. 9.
    Rosen ES, Gore CL, Taylor D, Chitkara D, Howes F, Kowalewski E (2002) Use of a digital infrared pupillometer to assess patient suitability for refractive surgery. J Cataract Refract Surg 288:1433–1438Google Scholar
  10. 10.
    Schallhorn SC, Kaupp SE, Tanzer DJ, Tidwell J, Laurent J, Bourque LB (2003) Pupil size and quality of vision after LASIK. Ophthalmology 1108: 1606–1614Google Scholar
  11. 11.
    Schmitz S, Krummenauer F, Henn S, Dick HB (2003) Comparison of three different technologies for pupil diameter measurement. Graefes Arch Clin Exp Ophthalmol 241:472–477 (Epub 2003 May 09)PubMedGoogle Scholar
  12. 12.
    Winn B, Whitaker D, Elliott DB, Phillips NJ (1994) Factors affecting light-adapted pupil size in normal human subjects. Invest Ophthalmol Vis Sci 35:1132–1137PubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2005

Authors and Affiliations

  • Emanuel Rosen
    • 1
  1. 1.Rosen Eye ClinicHarbour City Salford, ManchesterUK

Personalised recommendations