Advertisement

An Efficient Image Distortion Correction Method for an X-ray Digital Tomosynthesis System

  • J. Y. Kim
Conference paper
Part of the Lecture Notes in Computer Science book series (LNCS, volume 3776)

Abstract

Among X-ray cross-sectional imaging methods, digital tomosynthesis (DT) is very useful to PCB inspection because it can obtain a cross-sectional image of a local inspection area quickly. The image intensifier, which is usually used in DT systems, distorts X-ray images in shape and intensity. Therefore, image distortion correction is one of the most important issues in realizing a DT system. This paper presents an image distortion correction method to acquire an arbitrary cross-sectional image of an object by using a distance ratio function in an X-ray DT system. The method uses a simplified distortion model made by a distance ratio function in intensity correction, and by the 2D point mapping polynomials in shape correction.

References

  1. 1.
    Adams, J.: X-ray laminography analysis of ultra fine pitch solder connections on ultra-thin boards. In: SPIE Integrated Circuit Metrology, Inspection, and Process Control, vol. 1464, pp. 484–497 (1991)Google Scholar
  2. 2.
    Moore, T.D., Vanderstraeten, D., Forssell, P.M.: Three-dimensional x-ray laminography as a tool for detection and characterization of BGA package defects. IEEE Tr. on Components and Packaging Technologies 25(2), 224–229 (2002)CrossRefGoogle Scholar
  3. 3.
    Bossi, R.H., Georgeson, G.E.: Casting development savings with X-ray computed tomography. Casting, 181–188 (1993)Google Scholar
  4. 4.
    Bocage, E.M.: French Patent 536464 (1922)Google Scholar
  5. 5.
    Rooks, M., Sack, T.: X-ray inspection of flip chip attach using digital tomosynthesis. Circuit World 21(3), 51–55 (1995)CrossRefGoogle Scholar
  6. 6.
    Bord, S., Clement, A., Lecomte, J.C., Marmeggi, J.C.: An X-ray tomography facility for IC industry at STMicroelectronics Grenoble. Microelectronic engineering 62, 1069–1075 (2002)CrossRefGoogle Scholar
  7. 7.
    Sumimoto, T., Maruyamay, T., Azuma, Y., Goto, S., Mondo, M., Furukawa, N., Okada, S.: Detection of defects at BGA solder joints by using X-ray imaging. In: 2002 IEEE Int. Conf. on Industrial Technology, vol. 1, pp. 238–241 (2002)Google Scholar
  8. 8.
    Roh, Y.J., Ko, K.W., Cho, H.S., Kim, J.Y., Byun, J.E.: The calibration of X-ray digital tomosynthesis system including the compensation of the image distortion. In: SPIE Symp. on Intelligent Systems and Advanced Manufacturing VII, vol. 3528, pp. 248–259 (1998)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2005

Authors and Affiliations

  • J. Y. Kim
    • 1
  1. 1.Dept. of Mechatronics EngineeringTongmyong University of Information TechnologyBusanKorea