Abstract

Nowadays, many industries are using non-conventional energy sources to generate a huge amount of power/electricity, as these are non-pollutant. But connecting wind turbine to the power system or grid may lead to power quality issues such as voltage sag/swell, flicker, and harmonic and inter-harmonics. DVR is one of the CP devices used to mitigate voltage drop/raise (Srivastav and Sharma in Int J Adv Res Electr Electron Instr Eng 6(5), 2017 [1]). Sag is a more critical issue than swell. In this paper, sag and harmonic problems have been addressed. It demonstrates that how DVR injects voltage to compensate sags and reduces harmonics during fault. Here, the performance of DVR with PI controller, fuzzy controller, and hybrid fuzzy logic controller has been compared. The demonstration is done in MATLAB/Simulink.

Keywords

Custom power (CP) Dynamic voltage restorer (DVR) Wind energy system (WES) Permanent magnet synchronous generator (PMSG) Fuzzy logic controller (FLC) Hybrid fuzzy logic controller (HFLC) MATLAB/Simulink 

References

  1. 1.
    M. Srivastav, R. Sharma, Power quality improvement of distribution networks using dynamic voltage restore. Int J Adv Res Electr Electron Instr Eng 6(5), (2017).  https://doi.org/10.15662/ijareeie.2017.0605034
  2. 2.
    M.N. Eskander, S.I. Amer, Mitigation of voltage dips and swells in grid connected wind energy conversion systems. IETE J Res 57(6), 515 (2011)CrossRefGoogle Scholar
  3. 3.
    M. IIyas, Y. Rana, J.S. Khan, Analysis of the grid connected wind energy system using MATLAB/Simulink. Int J Adv Res Electr Electron Instr Eng 4(7), (2015)Google Scholar
  4. 4.
    D. Francis, T. Thomas, Mitigation of voltage sag and swell using dynamic voltage restorer. in International Conference on Magnetics and Drives (AICERA-2014 iCMMD)Google Scholar
  5. 5.
    P. Keertana, A. Chandana, Power quality enhancement for DFIG system by using HFLC based UPQC. Int J Adv Res Eng 7(02), (2018)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  • Basagonda Chandrika
    • 1
  • B. C. Sujatha
    • 2
  1. 1.Power and Energy SystemUVCE, Bangalore UniversityBangaloreIndia
  2. 2.Department of EEEUVCE, Bangalore UniversityBangaloreIndia

Personalised recommendations