Abstract

Nowadays the control and automation persuade the severe economic issues on expertise high rating equipments. Especially in distribution sector, it is required to provide elevated quality electrical services to improve the most significant issues of Power Quality (PQ) called Voltage Profile at load end, namely, Voltage Sags and Swells. The drive system failures, tripping of equipment, industrial, and domestic equipment shutdowns are the foremost occurrences by PQ issues. To attain a superlative dynamic capability of a distribution system, a Dynamic Voltage Restorer (DVR) is connected in series to it for voltage reparation of sensitive loads. The voltage sags and swells are mitigated with the help of Ultra-Capacitor (UCap) which will give more superlative characteristics because of low energy density, high power, and an efficiency of 85–90%. The UCap is selected because of the finest energy source device in terms of allowing for long life, safety in operation time, wide temperature range, and less maintenance cost. A bidirectional DC to DC converter is used to integrate the DVR and UCap which results a stiff dc-link voltage and compensates the temporary voltage sag and voltage swell. The Simulink model has been designed for the proposed system with PI Controller and Fuzzy Logic Controller for enhancing power quality in distribution sector and it is compared.

Keywords

DC to DC converter Ultra-Capacitor (UCap ) PI and fuzzy logic controller Dynamic Voltage Restorer (DVR) 

References

  1. 1.
    Edomah, N.: Effects of voltage sags, swell and other disturbances on electrical equipment and their economic implications. In: 20th International Conference on Electricity Distribution, Prague (2009)Google Scholar
  2. 2.
    Benachaiba, C., Ferdi, B.: Power quality improvement using DVR. Am. J. Appl. Sci. 6(3), 396–400 (2009)CrossRefGoogle Scholar
  3. 3.
    Abdul Basith, M.B., Sunitha, K.: A novel approach of dynamic voltage restorer integration with ultra capacitor for proper voltage sag compensation. In: 2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI), Chennai, pp. 578–582 (2017)Google Scholar
  4. 4.
    Potnuru, D., Kumar, J.S.V.S.: Design of a front-end DC-DC converter for a permanent magnet DC motor using fuzzy gain scheduling. In: 2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI), Chennai, pp. 1502–1505 (2017)Google Scholar
  5. 5.
    Carlos, G.A.d.A., Jacobina, C.B., dos Santos, E.C.: Investigation on dynamic voltage restorers with two DC links and series converters for three-phase four-wire systems. IEEE Trans. Ind. Appl. 52(2), 1608–1620 (2016)Google Scholar
  6. 6.
    Chandra, A., Singh, B., Singh, B.N., Al-Haddad, K.: An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads. IEEE Trans. Power Electron. 15(3), 495–507 (2000)CrossRefGoogle Scholar