Abstract

The self-study area is a typical and mostly-used space in the library, therefore the light environment in this room directly affects students’ learning efficiency and physical health. Field measurements and questionnaire surveys were conducted on the light environment. The results showed that the average illuminance of the artificial light environment could not meet the standard, while the average illuminance of the natural daylighting and mixed light environment far exceeded the standard, but the uniformity was poor. Aiming at the above problems, ECOTECT and DIALux were, respectively, used to study the effect of different shading forms and indoor light environment under different shading and lighting schemes. The results confirmed that among the three shading methods of the horizontal device, vertical device, and sun-shading blind, the effect of sun-shading blind shading is the best, and the environmental quality is optimal with the uniform arrangement of LED lamps. In addition, control recommendations combining natural daylighting with artificial lighting are proposed.

Keywords

Luminous environment ECOTECT simulation DIALux simulation Lighting control Energy conservation 

Notes

Acknowledgements

The project is supported by the Natural Science Foundation of China (Number 51778305).

All individual participants in the study had informed consent, and the survey also obtained permission from the library administrator.

References

  1. 1.
    Hwang, T., Jeong, T.K.: Effects of indoor lighting on occupants’ visual comfort and eye health in a green building. Indoor Built. Environ. 20(1), 75–90 (2011)CrossRefGoogle Scholar
  2. 2.
    Mak, C.M., Lui, Y.P.: The effect of sound on office productivity. Build. Serv. Eng. Res. Technol. 33(3), 339–345 (2012)CrossRefGoogle Scholar
  3. 3.
    Tang, M.F., Wang, D.N.: Energy efficiency analysis of window external shading in Chongqing. Build. Sci. 23(6), 60–63 (2007)Google Scholar
  4. 4.
    Nielsen, M.V., et al.: Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight. Sol. Energy 85(5), 757–768 (2011)CrossRefGoogle Scholar
  5. 5.
    Guan, J.L., Li, S.L.: Effect of exterior louvers building energy consumption and glare in hot summer and cold winter zone. HV&AC 48(02), 93–96 (2018)Google Scholar
  6. 6.
    MOHURD. GB 50034-2013: Standard for lighting design of buildings, Beijing (2012)Google Scholar
  7. 7.
    MOHURD. GB 50033-2013: Standard for daylighting design of buildings, Beijing (2013)Google Scholar
  8. 8.
    Li, T.Q., Luo, J.: Calculation of the size for sunshade board. Hebei J. Ind. Sci. Technol. 22(1), 20–21 (2005)Google Scholar
  9. 9.
    Li, Y.F., et al.: The accelerated aging characterization of high power LED. Chin. J. Lumin. 33(11), 1236–1240 (2012)CrossRefGoogle Scholar
  10. 10.
    Wang, Q.B., et al.: New testing method of aging LED lamp online. J. Appl. Opt. 36(4), 596–599 (2015)CrossRefGoogle Scholar

Copyright information