Advertisement

Study on Exhaust Uniformity of a Multi-terminal System

  • Yirui Wang
  • Jun GaoEmail author
Conference paper
  • 212 Downloads
Part of the Environmental Science and Engineering book series (ESE)

Abstract

Accompanied by the growth of high-rise residential, the main problems of the residential flue (uneven exhaust; deficiency exhaust; fumes and odor intrusion; fire hazard; and automatic control system design difficulty) are more prominent, which will lead to the fumes and cause great menace to human health. In order to improve the exhaust performance of the flue, this paper designed and installed a variable pressure plate in the centralized flue, and analyzed various factors (presence of variable pressure plate, opening rate, position distribution of open terminals) affecting the exhaust uniformity of the multi-terminal system through experiment. The results show that the installation of the plate in the reference condition can effectively improve the uniformity. The variance analysis and range analysis of the obtained data show that for the multi-terminal system without the variable pressure plate, the influence of opening rate on its uniformity is far greater than the position distribution; and the influence of terminal position distribution is much more than the opening rate in the multi-terminal system with the transformer plate.

Keywords

Multi-terminal system Exhaust uniformity Variable pressure plate Opening rate Position distribution of open terminals 

Notes

Acknowledgements

This research has been supported by the National Natural Science Foundation of China (NSFC) for its financial support for the research project ‘research on the uniform and adaptive smoke exhaust dynamics and design methods of high-rise residential kitchens’ (No. 51578387).

References

  1. 1.
    China Statistics Bureau.: Statistical bulletin of the national economic and social development of the People’s Republic of China in 2017. http://www.stats.gov.cn/tjsj/zxfb/201802/t20180228_1585631.html. Last accessed 07 Apr 2019 (2017)
  2. 2.
    Liu, H.Y., Yang, F., Xu, Y.J.: Analysis of urban housing situation in China based on 2010 census data. Journal of Tsinghua University(Philosophy and Social Sciences), 28(06), 138–147 + 158 (2013)Google Scholar
  3. 3.
    You, M.T.: Aerodynamic Performance of Residential Exhaust System. Shenyang University of Architecture, Shenyang (2014)Google Scholar
  4. 4.
    Xiong, J.: The Research about the Characteristics and Optimization of High-Rise Residential Kitchens Centralized Exhaust System. Chongqing University, Chongqing (2016)Google Scholar
  5. 5.
    Liu, N.: Research on Centralized Smoke Exhaust (Wind) System in High-rise Residential Buildings. Xi’an University of Architecture and Technology, Xi’an (2009)Google Scholar
  6. 6.
    Wang, H.C.: Experimental and Simulation Study on Diversion Components of a Centralized Flue Gas Airway System in High-Rise Residential Kitchens. Xi’an University of Architecture and Technology, Xi’an (2013)Google Scholar
  7. 7.
    Yang, T.: Consideration on fire hazard and fire extinguishing device in kitchen. J. Tongling Univ. 10(06), 102–103 (2011)Google Scholar
  8. 8.
    Wang, X.X.: Research on Design Method of Centralized Flue Gas System in High-Rise Residential Kitchens. Tongji University, Shanghai (2006)Google Scholar
  9. 9.
    Shao, Z.M.: Simulation Research on Centralized Exhaust System in High-Rise Residential Kitchens. Xi’an University of Architecture and Technology, Xi’an (2010)Google Scholar
  10. 10.
    ASHRAE Handboook.: HVAC Applications, Chapter 33 Kitchen Ventilation. American Society of Heating, Refrigerating and Air-conditioning Engineers, Atlanta, USA (2015)Google Scholar
  11. 11.
    Wu, L.: Research on Design of Central Fume Exhaust for Residential Kitchens in High-rise Buildings based on Controlled Flue Area. Tongji University, Shanghai (2017)Google Scholar
  12. 12.
    GB50352-2005, Code for design of civil buildingsGoogle Scholar
  13. 13.
    Liu, S.L., Liu, W.T.: Experimental development process of a new fluid-solid coupling similar-material based on the orthogonal test. Processes 6(11), 17 (2018)Google Scholar
  14. 14.
    Xie, Y.L.: Study on Spray Cooling Effect in Long and Narrow Space Strong Disturbance Process. Tongji University, Shanghai (2018)Google Scholar

Copyright information