Advertisement

A New Safety Design of the Ceiling Fan to Avoid Suicidal Cases

  • Abinash Mishra
  • Balamurali Gunji
  • B. B. V. L. Deepak
Conference paper
Part of the Smart Innovation, Systems and Technologies book series (SIST, volume 134)

Abstract

In recent years due to heavy stress and mental depression, in many parts of the world people commit suicides and lose their lives, leaving their family and relatives. From all around the world, approximately 17% of the suicide cases that are registered from the year 1987 to 2017 are from India. Among those, hanging to death from a ceiling fan is one of the major methods of suicide. In this paper, a new safety design is proposed for ceiling fans to prevent suicidal cases. Initially, stress analysis has been done on the general existing model fans to evaluate the force exerted by its own weight of the fan on the down rod. Depending on the results, the modification to the ceiling fan will improve the design from any mishap. In this new design, the down road is replaced with a spring that connects it to the ceiling of the house. The spring is designed such that, the rigidity of the spring fails when it encounters more weight than the designed safe load. Due to rigidity failure of the spring, the spring elongates and the fan lowers down, thus preventing the person from death by hanging. The Computer-Aided Design (CAD) model of the ceiling fan is made in SolidWorks and the analysis of down rod is done in ANSYS. However, the analysis of spring assembly is done in SolidWorks.

Keywords

ANSYS SolidWorks Computer-aided design Down rod 

References

  1. 1.
    Deepak, B.B., Bala Murali: CAD Modelling Using Dassault Systems SolidWorks (2017)Google Scholar
  2. 2.
    Templeman.co: Small spring specialist since 1938, spring design formulasGoogle Scholar
  3. 3.
    Ahmad, M., Hossain, M.Z.: Hanging as a Method of Suicide Retrospective Analysis of Post-mortem CasesGoogle Scholar
  4. 4.
    Vijayakumari, N.: Suicidal Hanging: a Prospective StudyGoogle Scholar
  5. 5.
    Sali, S., Sadaphale, D.B., Patil, N.K.: Evaluation of Ceiling Fan Blade Angle Performance Using CFDGoogle Scholar
  6. 6.
    Eliasson, A., Westman, M.: Redesign of Ceiling Fan Adapted to the Scandinavian MarketGoogle Scholar
  7. 7.
    Bhortake, R.: Experimental analysis of energy consumption in ceiling fan. Department of Mechanical Engineering, PVPIT Savitribai Phule Pune University Pune, Vaishali Bhortake, Pune, MaharashtraGoogle Scholar
  8. 8.
    Adeeb1, E., Maqsood, A., Musthaq, A., Sohn, C.H.: Parametric Study and Optimization of Ceiling Fan Blades for Improved Aerodynamic PerformanceGoogle Scholar
  9. 9.
    Analysis of standards options for ceiling fans, Davis Energy Group Energy Solutions May 9, 2004Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  • Abinash Mishra
    • 1
  • Balamurali Gunji
    • 1
  • B. B. V. L. Deepak
    • 1
  1. 1.National Institute of TechnologyRourkelaIndia

Personalised recommendations