Advertisement

A Novel Design Architecture to Address the Current Limitations of Fixed and Mobile Phone Data Logging System

  • Ajit Kumar GopeeEmail author
  • Phaleksha Ujoodha
  • Vinaye Armoogum
  • Yashwantrao Ramma
Conference paper
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 863)

Abstract

Data loggers are devices used to gather data in various environment. However, if they undergo any malfunction or breakdown, data cannot be recovered. Most phone data loggers have a small LCD to display the caller ID only, though a few can also display date and time. Others may not have a display at all and the call information has to be viewed on an external PC. Most of them have limited internal memory of 20 calls only and then are overwritten by the new ones. Some telephone requires an external call recording device since no data logger provides this functionality yet. The EEPROM of the Arduino has limited storage capacity, issues with nature and format of data for executing high load programs. So the present paper attempts to propose a novel design architecture to address these issues. Preliminary output shows that the DTMF decoder could only detect key pressed on a fixed telephone. By using a micro SD card, it is possible to store more data and variables in the Arduino sketch. Unfortunately, for some unknown reasons, the circuit could not detect incoming calls even when the DTMF decoder was replaced with an FSK one. In parallel, an Android app has been being developed that can log the caller ID and indicate the date, time, day, duration, and the type of call such as incoming or outgoing call on an Android mobile phone.

Keywords

Data logger Mobile/fixed phones DTMF and FSK decoders Arduino EEPROM Extended memory and storage 

References

  1. 1.
    Jan, T.: Design and development of a data logger based on IEEE 802.15.4/ZigBee and GSM. In: Proceedings of the Pakistan Academy of Sciences: Pakistan Academy of Sciences A. Physical and Computational Sciences, 53(1), 37–48, p. 1 (2016)Google Scholar
  2. 2.
    NehaChourasia, S.N.: Review paper on industrial datalogging system. Int. J. Res. Emerg. Sci. Technol. special-Issue-1-JAN-2017, Dahegaon, Nagpur, India (2017)Google Scholar
  3. 3.
    Implementing a data logger with spansion SPI Flash. Zilog Embed. Life Oixys Company, Multimotor Ser. p. 1 (2013)Google Scholar
  4. 4.
    Sio-lin Ao, B.R.: Machine Learning and System Engineering, Springer science + business media B.V, Dordrecht, Heidelberg, London, New York (2010)Google Scholar
  5. 5.
    Thanutong, P.: Implementation of low cost data logger using flash disk with file allocation tableGoogle Scholar
  6. 6.
    Akposionu, K.N.: Design and fabrication of a Low-cost data logger for solar energy parameters. J. Energy Technol. Policy 2. ISSN 2224-3232, p. 1 (2012)Google Scholar
  7. 7.
    Derek Liu, D.U.: The USB data logger based on the MC9S08JM60. Freescale Semicond. p. 1 (2008)Google Scholar
  8. 8.
    LocalLaw87. Data logging: Online, Available http://www.local-law-87.com/content/data-logging. Accessed 30 05 2018 (2018)
  9. 9.
    Onsetcomp.com. What is a data logger? — onset data loggers: Online, Available http://www.onsetcomp.com/what-is-a-data-logger. Accessed 14/ 04/ 2018 (2017)
  10. 10.
    Evidencia.biz. Types of data loggers mechanical, digital, and wireless: Online, Available http://www.evidencia.biz/what-is/types.htm. Accessed 14/ 04/ 2018 (2010)
  11. 11.
    Hailegiorgis, H.: Implementing a data logger for home automation: Online, Available https://www.theseus.fi/bitstream/handle/10024/93734/Thesis_Final.pdf. Accessed 05 06 2018 (2010)
  12. 12.
    M. Technologies. Microcontroller based data logger: Online, Available https://www.projectsof8051.com/microcontroller-based-data-logger/. Accessed 01/ 06/ 2018 (14/ 06/ 2013)
  13. 13.
    Quingnan, S., Changsuo, Z., Min, L., Cong, Q., Xingwei, B.: Telecord that can be connected with computer: Online, Available https://patents.google.com/patent/CN205681521U/en. Accessed 30/ 05/ 2018 (2016)
  14. 14.
    Hsieh, M.-T.: Device for automatically identifying DTMF and FSK for caller ID: Online, Available https://patents.google.com/patent/US6683948. Accessed 30/ 05/ 2018 (2004)
  15. 15.
    LABS, L. DTMF: Online, Available http://www.lemalabs.com/dtmf/. Accessed 30/ 05/ 2018 (2015)
  16. 16.
    Figa, R., Cohen, J.H., Cohen, S.G.: Automatic incoming telephone call originating number and party display system: Online, Available https://patents.google.com/patent/US4924496A/en. Accessed 31/ 05/ 2018 (08/ 05/ 1990)
  17. 17.
    WhatsApp Encryption Overview. Technical white paper, December 19, 2017, Originally published April 5 (2016)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  • Ajit Kumar Gopee
    • 1
    Email author
  • Phaleksha Ujoodha
    • 1
  • Vinaye Armoogum
    • 1
  • Yashwantrao Ramma
    • 2
  1. 1.School of Innovative Technologies and EngineeringUniversity of TechnologyPort LouisMauritius
  2. 2.School of Science and MathsMauritius Institute of EducationReduitMauritius

Personalised recommendations