Characteristics of Indoor Environmental Quality

  • Pranab Kumar Nag
Chapter
Part of the Design Science and Innovation book series (DSI)

Abstract

Indoor environmental quality (IEQ) in an office/non-residential building is determined by environmental aspects, covering the physical (lighting, acoustics, and thermal conditions), chemical (indoor air quality), and biological (microorganisms) origins. This chapter focuses on the assessment of chemical and physical parameters, particulates including PM10, PM2.5, and aerosols, CO2, CO, NOx, VOCs, black carbon, radon concentration, climatic factors, acoustic and lighting, and also the characterization of fungal and other microbial contaminants. Hundreds of VOCs have been identified in indoor air. Different range of concentrations of the VOC classes indicates source apportionment of indoor VOCs. The VOCs provoke symptoms typical of SBS, including mucous membrane annoyance, skin irritation, exacerbation of asthma, fatigue, liver, and kidney damage and increased cancer risks. A section is dedicated to lAQ management, concerning guidelines of exposure included in green building rating schemes. In managing IAQ, the preferred pathways are (i) emission source control, aiming at choosing low-emission indoor materials, building construction and renovation practices, (ii) ventilation to provide for appropriate indoor/outdoor air exchange, and (iii) periodic indoor air monitoring to comply with the given threshold.

References

  1. ACGIH. (2001/2003) Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, 6500 Glenway, Building D-7, Cincinnati, OH, USA.Google Scholar
  2. Anderson, S. E., Franko, J., Jackson, L. G., Wells, J. R., Ham, J. E., & Meade, B. J. (2012). Irritancy and allergic responses induced by exposure to the indoor air chemical 4-oxopentanal. Toxicological Sciences, 127(2), 371–381.Google Scholar
  3. Anderson, S. E., Jackson, L. G., Franko, J., & Wells, J. R. (2010). Evaluation of dicarbonyls generated in a simulated indoor air environment using an in vitro exposure system. Toxicological Sciences, 115(2), 453–461.Google Scholar
  4. ANSI/ASHRAE (1989/2007/2010/2013). 62.1-2013, Ventilation for Acceptable Indoor Air Quality. ASHRAE, Atlanta, Georgia. http://www.ashrae.org.
  5. ANSI/ASHRAE 55 (2004, 2007, 2009, 2010, 2013 versions). Thermal Environmental Conditions for Human Occupancy, ASHRAE, Atlanta, GA.Google Scholar
  6. Apte, M. G., Buchanan, I. S. H., & Mendell, M. J. (2008). Outdoor ozone and building-related symptoms in the BASE study. Indoor Air, 18(2), 156–170.Google Scholar
  7. ASHRAE. (2009). Chapter 9: Thermal Comfort in ASHRAE Handbook: Fundamentals (SI). ASHRAE, Atlanta, Georgia.Google Scholar
  8. Bennett, D. H., Apte, M., Wu, X., Trout, A., Faulkner, D., Maddalena, R., & Sullivan, D. (2011). Indoor environmental quality and heating, ventilating, and air conditioning survey of small and medium size commercial buildings: Field study. Final Report for CEC-500-2011-043, California Energy Commission, Sacramento, California (USA).Google Scholar
  9. Benton, C., Bauman, F., & Fountain, M. (1990). A field measurement system for the study of thermal comfort. ASHRAE Transactions, 96, 623–633.Google Scholar
  10. Bernhard, C. A., Kirchner, S., Knutti, R., & Lagoudi, A. (1995). Volatile organic compounds in 56 European office buildings. In Maroni, M. (Ed.), Proceedings of the Healthy Buildings, Milan (Vol. 95, pp. 1347–1352).Google Scholar
  11. Bluyssen, P. M. (2009). The indoor environment handbook: How to make buildings healthy and comfortable. London: Routledge.Google Scholar
  12. Bornehag, C. G., Lundgren, B., Weschler, C. J., Sigsgaard, T., Hagerhed-Engman, L., & Sundell, J. (2005). Phthalates in indoor dust and their association with building characteristics. Environmental Health Perspectives, 113(10), 1399.Google Scholar
  13. Bornehag, C. G., & Stridh, G. (2000). Volatile organic compounds (VOCs) in the Swedish housing stock. In Seppanen, O., Sateri, J. (Eds.), Proceedings of the Healthy Buildings 2000, Espoo (Vol. 1, pp. 437–442).Google Scholar
  14. BREEAM. (2014, 2016). Building Research Establishment Environmental Assessment Method, developed by BRE (UK), http://www.breeam.org.
  15. Brightman, H. S., Milton, D. K., Wypij, D., Burge, H. A., & Spengler, J. D. (2008). Evaluating building-related symptoms using the US EPA BASE study results. Indoor Air, 18(4), 335–345.Google Scholar
  16. Brown, S. K. (1999). Occurring of volatile organic compounds in indoor air. In T. Salthammer (Ed.), Organic Indoor Air Pollutants (pp. 171–184). Weinheim: Wiley-VCH.Google Scholar
  17. Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994). Concentrations of volatile organic compounds in indoor air–a review. Indoor Air, 4(2), 123–134.Google Scholar
  18. Buonanno, G., Morawska, L., Stabile, L., & Viola, A. (2010). Exposure to particle number, surface area and PM concentrations in pizzerias. Atmospheric Environment, 44(32), 3963–3969.Google Scholar
  19. Burton, L. E., Baker, B., Hanson, D., Girman, J. G., Womble, S. E., & McCarthy, J. F. (2000). Baseline information on 100 randomly selected office buildings in the United States (BASE): Gross building characteristics. In Proceedings of Healthy Buildings 2000 (Vol. 1, pp. 151–155). http://www.epa.gov/iaq/base/pdfs/basea2396.pdf.
  20. CARB. (2005). Report to the California legislature: Indoor air pollution in California. Pursuant to Health and Safety code 39930 (Assembly Bill 1173, Keeley, 2002). California Air Resources Board, Call No. A 1165 I422 2005, http://www.carb.ca.gov/research/apr/reports/l3041.pdf.
  21. Chen, C., & Zhao, B. (2011). Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor. Atmospheric Environment, 45(2), 275–288.Google Scholar
  22. Chiang, C. M., Chou, P. C., Lai, C. M., & Li, Y. Y. (2001). A methodology to assess the indoor environment in care centers for senior citizens. Building and Environment, 36(4), 561–568.Google Scholar
  23. Choi, J. H., Loftness, V., & Aziz, A. (2012). Post-occupancy evaluation of 20 office buildings as basis for future IEQ standards and guidelines. Energy and Buildings, 46, 167–175.Google Scholar
  24. Clausen, P. A., Wilkins, C. K., & Nielsen, G. D. (2000). Formation of strong airway irritants in terpene/ozone mixtures. Indoor Air, 10(2), 82–91.Google Scholar
  25. Demokritou, P., Lee, S. J., Ferguson, S. T., & Koutrakis, P. (2004). A compact multistage (cascade) impactor for the characterization of atmospheric aerosols. Journal of Aerosol Science, 35(3), 281–299.Google Scholar
  26. DGNB. (2009). German sustainable building certificate: Structure—application—criteria. Stuttgart, 2nd English Edition, http://www.dgnb.de/.
  27. EN 13779. (2006). Ventilation for non-residential buildings e performance requirements for ventilation and room-conditioning systems. CEN.Google Scholar
  28. EN 15251. (2007). Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings—Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics, CEN, Brussels.Google Scholar
  29. Environmental Health and Engineering, EHE. (2002). A Screening-Level Ranking of Organic Chemicals and Metals Found in Indoor Air. Newton, Massachusetts. Environmental Health and Engineering, Inc.Google Scholar
  30. Estidama Pearl Rating system, Abu Dhabi, UAE Urban Planning Council, 2011.Google Scholar
  31. Forester, C. D., & Wells, J. R. (2009). Yields of carbonyl products from gas-phase reactions of fragrance compounds with OH radical and ozone. Environmental Science and Technology, 43(10), 3561–3568.Google Scholar
  32. Girman, J. R., Hadwen, G. E., Burton, L. E., Womble, S. E., & McCarthy, J. F. (1999). Individual volatile organic compound prevalence and concentrations in 56 buildings of the building assessment survey and evaluation (BASE) study. Indoor Air, 99, 460–465.Google Scholar
  33. Green Globes. (2010). ANSI/GBI 01–2010: Green Building Assessment Protocol for Commercial Buildings. Green Building Initiative, Jessup, MD, USA, http://www.thegbi.org.
  34. GREENSHIP. Indonesia Green Building Council Indonesia (GBCI), www.gbcindonesia.org.
  35. Harrad, S., de Wit, C. A., Abdallah, M. A. E., Bergh, C., Björklund, J. A., Covaci, A., et al. (2010). Indoor contamination with hexabromocyclododecanes, polybrominated diphenyl ethers, and perfluoroalkyl compounds: An important exposure pathway for people? Environmental Science and Technology, 44(9), 3221–3231.Google Scholar
  36. Hauser, R., & Calafat, A. M. (2005). Phthalates and human health. Occupational and Environmental Medicine, 62(11), 806–818.Google Scholar
  37. Heinzerling, D., Schiavon, S., Webster, T., & Arens, E. (2013). Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme. Building and Environment, 70, 210–222.Google Scholar
  38. Helmis, C. G., Tzoutzas, J., Flocas, H. A., Halios, C. H., Stathopoulou, O. I., Assimakopoulos, V. D., et al. (2007). Indoor air quality in a dentistry clinic. Science of the Total Environment, 377(2), 349–365.Google Scholar
  39. HKBEAM Society. (2003). HK-BEAM: The Hong Kong Building Environmental Assessment Method, http://www.hk-beam.org.hk/general/home.php.
  40. Hodgson, A. T., Faulkner, D., Sullivan, D. P., DiBartolomeo, D. L., Russell, M. L., & Fisk, W. J. (2003). Effect of outside air ventilation rate on volatile organic compound concentrations in a call center. Atmospheric Environment, 37(39), 5517–5527.Google Scholar
  41. Holcomb, L. C., & Seabrook, B. S. (1995). Indoor concentrations of volatile organic compounds: Implications for comfort, health and regulation. Indoor Environment, 4(1), 7–26.Google Scholar
  42. HQE (Haute Qualité Environnementale)—France, http://assohqe.org/hqe/ 2005, by CSTB (Centre Scientifique et Technique du Bâtiment).
  43. Hummel, T., Dalton, P., & Dilks, D. D. (2000). Effects of exposure to irritants. Chemical Senses, 25, 788.Google Scholar
  44. Hunt, A., Johnson, D. L., Brooks, J., & Griffith, D. A. (2008). Risk remaining from fine particle contaminants after vacuum cleaning of hard floor surfaces. Environmental Geochemistry and Health, 30(6), 597–611.Google Scholar
  45. ISO 14644-1. (1999). Cleanrooms and associate controlled environments—Part 1—classification of air cleanliness. The Institute of Environmental Sciences and Technology (IEST), 5005 Newport Drive, Suite 506, Rolling Meadows, IL 60008, USA, 18p.Google Scholar
  46. ISO 16000-3. (2011). Indoor air—part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air—active sampling method. 2011. https://www.iso.org/obp/ui/#iso:std:iso:16000:-3:ed-2:v1:en.
  47. ISO 16000-6. (2011). Indoor air—Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID.Google Scholar
  48. ISO 16000-28. (2012). Indoor air—Part 28: Determination of odour emissions from building products using test chambers.Google Scholar
  49. ISO/IEC/17025:2005. (2005). General requirements for the competence of testing and calibration laboratories.Google Scholar
  50. Julien, R., Adamkiewicz, G., Levy, J. I., Bennett, D., Nishioka, M., & Spengler, J. D. (2008). Pesticide loadings of select organophosphate and pyrethroid pesticides in urban public housing. Journal of Exposure Science & Environmental Epidemiology, 18(2), 167–174.Google Scholar
  51. Kim, H., & Haberl, J. (2012a). Field-test of the new ASHRAE/CIBSE/USGBC performance measurement protocols for commercial buildings: Basic level. ASHRAE Transactions 118.Google Scholar
  52. Kim, H., & Haberl, J.S. (2012b). Field-test of the new ASHRAE/CIBSE/USGBC performance measurement protocols: Intermediate and advanced level indoor environmental quality protocols. ASHRAE Transactions, 118(2), 58–65.Google Scholar
  53. Klenø, J., & Wolkoff, P. (2004). Changes in eye blink frequency as a measure of trigeminal stimulation by exposure to limonene oxidation products, isoprene oxidation products and nitrate radicals. International Archives of Occupational and Environmental Health, 77(4), 235–243.Google Scholar
  54. klima:aktiv house, http://www.klimaaktiv.at.
  55. Knol, A. B., Nemery, B., Brunekreef, B., Lebret, E., Cassee, F. R., Forastiere, F., et al. (2009). Expert elicitation on ultrafine particles: Likelihood of health effects and causal pathways. Particle and Fibre Toxicology, 6(1), 19.Google Scholar
  56. Lai, A. C. (2006). Particle deposition and decay in a chamber and the implications to exposure assessment. Water, Air, and Soil pollution, 175(1), 323–334.Google Scholar
  57. LEED (Leadership in Energy and Environmental Design). U.S. Green Building Council (USGBC), LEED Version 4 (updated 2016), http://www.usgbc.org/leed.
  58. Li, T. H., Turpin, B. J., Shields, H. C., & Weschler, C. J. (2002). Indoor hydrogen peroxide derived from ozone/d-limonene reactions. Environmental Science and Technology, 36(15), 3295–3302.Google Scholar
  59. Logue, J. M., Small, M. J., & Robinson, A. L. (2009). Identifying priority pollutant sources: Apportioning air toxics risks using positive matrix factorization. Environmental Science and Technology, 43(24), 9439–9444.Google Scholar
  60. MADEP (Massachusetts Department of Environmental Protection). (2002). WSC POLICY: 02-430. Indoor Air Sampling and Evaluation Guide. Office of Research and Standards. Department of Environmental Protection. CommonHealth of Massachusetts, U.S 157.Google Scholar
  61. MAK–Maximum Concentrations at the Workplace and Biological Tolerance Values for Working Materials 2000. Commission for the Investigation of Health Hazard of Chemical Compounds in the Work Area, Federal Republic of Germany.Google Scholar
  62. Meng, Q. Y., Turpin, B. J., Lee, J. H., Polidori, A., Weisel, C. P., Morandi, M., et al. (2007). How does infiltration behaviour modify the composition of ambient PM2.5 in indoor spaces? An analysis of RIOPA data. Environmental Science and Technology, 41(21), 7315–7321.Google Scholar
  63. Mohammadyan, M., Ashmore, M., & Shabankhani, B. (2010). Indoor PM2.5 concentrations in the office, café, and home. International Journal of Occupational Hygiene, 2(2), 57–62.Google Scholar
  64. Morgan, M. K., Sheldon, L. S., Croghan, C. W., Jones, P. A., Chuang, J. C., & Wilson, N. K. (2007). An observational study of 127 preschool children at their homes and daycare centers in Ohio: Environmental pathways to cis-and trans-permethrin exposure. Environmental Research, 104(2), 266–274.Google Scholar
  65. Morrison, G. (2008). Interfacial chemistry in indoor environments. Environmental Science and Technology, 42(10), 3495–3499.Google Scholar
  66. Morrison, G. C., & Nazaroff, W. W. (2002). Ozone interactions with carpet: Secondary emissions of aldehydes. Environmental Science and Technology, 36(10), 2185–2192.Google Scholar
  67. Mui, K. W., & Chan, W. T. (2005). A new indoor environmental quality equation for air-conditioned buildings. Architectural Science Review, 48(1), 41–46.Google Scholar
  68. Mullen, N. A., Bhangar, S., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011). Ultrafine particle concentrations and exposures in six elementary school classrooms in northern California. Indoor Air, 21(1), 77–87.Google Scholar
  69. NABERS–Australia National Australian Building Environmental Rating Scheme (2000), www.abgr.com.au.
  70. NAS. (1998). Health effects of exposure to radon (BEIR VI). Washington DC: National Academy of Sciences.Google Scholar
  71. Nazaroff, W. W., & Weschler, C. J. (2004). Cleaning products and air fresheners: Exposure to primary and secondary air pollutants. Atmospheric Environment, 38(18), 2841–2865.Google Scholar
  72. Newsham, G., et al. (2012). Do green buildings outperform conventional buildings. Indoor environment and energy performance in North American offices.Google Scholar
  73. Nicol, J. F., & McCartney, K. (2000). Smart controls and thermal comfort project. SCATs final report, Oxford.Google Scholar
  74. Nøjgaard, J. K., Bilde, M., Stenby, C., Nielsen, O. J., & Wolkoff, P. (2006). The effect of nitrogen dioxide on particle formation during ozonolysis of two abundant monoterpenes indoors. Atmospheric Environment, 40(6), 1030–1042.Google Scholar
  75. OEHHA. (2010). Acute, 8-hour and Chronic Reference Exposure Level (REL)s. Office of Environmental Health Hazard Assessment, http://www.oehha.ca.gov/air/a11re1s.htm1.
  76. Paliaga, G. (2004). Operable windows, personal control and occupant comfort. Berkeley: University of California.Google Scholar
  77. Panagiotaras, D., Nikolopoulos, D., Petraki, E., Kottou, S., Koulougliotis, D., Yannakopoulos, P., et al. (2014). Comprehensive experience for indoor air quality assessment: A review on the determination of volatile organic compounds (VOCs). Journal of Physical Chemistry & Biophysics, 4(5), 1.Google Scholar
  78. Piazza, T., & Apte, M. (2010). Indoor Environmental Quality and Heating, Ventilating, and Air Conditioning Survey of Small-and Medium-Size Commercial Buildings. California Energy Commission.Google Scholar
  79. Reitzig, M., Mohr, S., Heinzow, B., & Knöppel, H. (1998). VOC emissions after building renovations: Traditional and less common indoor air contaminants, potential sources, and reported health complaints. Indoor Air, 8(2), 91–102.Google Scholar
  80. Rose, M., Bennett, D. H., Bergman, Å., Fängström, B., Pessah, I. N., & Hertz-Picciotto, I. (2010). PBDEs in 2–5 year-old children from California and associations with diet and indoor environment. Environmental Science and Technology, 44(7), 2648–2653.Google Scholar
  81. Samet, J., & Krewski, D. (2007). Health effects associated with exposure to ambient air pollution. Journal of Toxicology and Environmental Health, Part A, 70(3–4), 227–242.Google Scholar
  82. Sarnat, S. E., Coull, B. A., Ruiz, P. A., Koutrakis, P., & Suh, H. H. (2006). The influences of ambient particle composition and size on particle infiltration in Los Angeles, CA, residences. Journal of the Air and Waste Management Association, 56(2), 186–196.Google Scholar
  83. Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., et al. (2006). Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone. Atmospheric Environment, 40(35), 6696–6710.Google Scholar
  84. Sotiriou, M., Ferguson, S. F., Davey, M., Wolfson, J. M., Demokritou, P., Lawrence, J., et al. (2008). Measurement of particle concentrations in a dental office. Environmental Monitoring and Assessment, 137(1–3), 351–361.Google Scholar
  85. Stewart, J. C., Chalupa, D. C., Devlin, R. B., Frasier, L. M., Huang, L. S., Little, E. L., et al. (2010). Vascular effects of ultrafine particles in persons with type 2 diabetes. Environmental Health Perspectives, 118(12), 1692–1698.Google Scholar
  86. Syazwan, A. I., Juliana, J., Norhafizalina, O., Azman, Z. A., & Kamaruzaman, J. (2009). Indoor air quality and sick building syndrome in Malaysian buildings. Global Journal of Health Science, 1(2), 126–135.Google Scholar
  87. TGBRS (2003). Teri Green Building Rating System, India.Google Scholar
  88. Tian, L., Zhang, G., Yu, J., Zhang, Q., & Zhou, J. (2008). Impact of surface roughness on particle penetration through building envelope leakage. International Journal of Energy Technology and Policy, 6(5–6), 534–542.Google Scholar
  89. US EPA. (2003). A Standardized EPA Protocol for Characterizing Indoor Air Quality in Large Office Buildings, Office of Research and Development and Office of Air and Radiation, U.S. EPA., Washington, D.C.Google Scholar
  90. UK, HPA. (2009). Radon and Public Health: Report of the Subgroup on Radon Epidemiology of the Independent Advisory Group on Ionising Radiation, Health Protection Agency, UK.Google Scholar
  91. US EPA. (2007). NAAQS Table, National Ambient Air Quality Standards. 2007, https://www.epa.gov/criteria-air-pollutants/naaqs-table.
  92. US EPA, IRIS (2010). Integrated Risk Information System. Environmental Protection Agency, http://www.epa.gov/IRIS/.
  93. US EPAct. (2005). Energy policy act of 2005, United States Public Law 109-58.Google Scholar
  94. US OSHA. (1989). Air Contaminants-Permissible Exposure limits (Title 29, Code of Federal Regulations, Part 1910.1000).Google Scholar
  95. US OSHA. (1994). OSHA Regulations (Standards-29 CFR) Part 1910 OSHA Z Toxic and Hazardous Substances 1910.1000 TABLE Z-1 Limits for Air Contaminants. Occupational Safety and Health Administration. Washington, D.C.Google Scholar
  96. US OSHA, A. (2003). Brief Guide to Mold in the Workplace. Occupational Safety and Health Administration, US Department of Labor, Washington, DC, http://www.osha.gov/dts/shib/shib101003.pdf.
  97. US-EPA. (1990). Compendium of methods for the determination of air pollutants in indoor air. In E. S. F. A. R. A. E. A (Ed.), Laboratory, Office of Research and Development, EPA, North Carolina.Google Scholar
  98. US-EPA. (1984). Compendium of methods for the determination of toxic organic compounds in ambient air. Compiled by R.M. Riggin of Battelle-Columbus Laboratories, Columbus, Ohio for Environmental Monitoring System Laboratory, EPA, Research Triangle Park, North Carolina.Google Scholar
  99. US-EPA. (1999). Compendium of methods for the determination of toxic organic compounds in ambient air. In C. F. E (Ed.), Information, Environment Protection Agency (2nd ed.).Google Scholar
  100. Valavanidis, A., Fiotakis, K., & Vlachogianni, T. (2008). Airborne particulate matter and human health: Toxicological assessment and importance of size and composition of particles for oxidative damage and carcinogenic mechanisms. Journal of Environmental Science and Health, Part C, 26(4), 339–362.Google Scholar
  101. Vartiainen, E., Kulmala, M., Ruuskanen, T. M., Taipale, R., Rinne, J., & Vehkamäki, H. (2006). Formation and growth of indoor air aerosol particles as a result of D-limonene oxidation. Atmospheric Environment, 40(40), 7882–7892.Google Scholar
  102. Wallace, L., & Ott, W. (2011). Personal exposure to ultrafine particles. Journal of Exposure Science & Environmental Epidemiology, 21(1), 20–30.Google Scholar
  103. Webster, T., Bauman, F., & Anwar, G. (2007). CBE Portable Wireless Monitoring System (PWMS): UFAD systems commissioning cart design specifications and operating manual.Google Scholar
  104. Wei, W., Ramalho, O., & Mandin, C. (2015). Indoor air quality requirements in green building certifications. Building and Environment, 92, 10–19.Google Scholar
  105. Weschler, C. J. (2006). Ozone’s impact on public health: Contributions from indoor exposures to ozone and products of ozone-initiated chemistry. Environmental Health Perspectives, 114(10), 1489–1496.Google Scholar
  106. Wilkins, C. K., Larsen, S. T., Hammer, M., Poulsen, O. M., WWkoff, P., & Nielsen, G. D. (1998). Respiratory effects in mice exposed to airborne emissions from Stachybotrys chartarum and implications for risk assessment. Basic & Clinical Pharmacology & Toxicology83(3), 112–119.Google Scholar
  107. World Bank Group (2008, December). Environmental, Health, and Safety Guidelines: THERMAL POWER PLANTS. International Finance Corporation (p. 33), http://www.ifc.org/ifcext/sustainability.nsf/AttachmentsByTitle/gui_EHSGuidelines2007_ThermalPower/$FILE/FINAL_Thermal+Power.pdf.
  108. World Health Organization (WHO). (2010). WHO guidelines for indoor air quality: Selected pollutants. WHO Regional Office for Europe; ISBN 978-92-890-0213-4.Google Scholar
  109. Zock, J. P., Vizcaya, D., & Le Moual, N. (2010). Update on asthma and cleaners. Current opinion in Allergy and Clinical Immunology, 10(2), 114–120.Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  • Pranab Kumar Nag
    • 1
  1. 1.School of Environment and Disaster ManagementRamakrishna Mission Vivekananda UniversityKolkataIndia

Personalised recommendations