Advertisement

A Novel Ultrasound-Based Lower Extremity Motion Tracking System

  • Kenan Niu
  • Victor Sluiter
  • Jasper Homminga
  • André Sprengers
  • Nico Verdonschot
Chapter
Part of the Advances in Experimental Medicine and Biology book series (AEMB, volume 1093)

Abstract

Tracking joint motion of the lower extremity is important for human motion analysis. In this study, we present a novel ultrasound-based motion tracking system for measuring three-dimensional (3D) position and orientation of the femur and tibia in 3D space and quantifying tibiofemoral kinematics under dynamic conditions. As ultrasound is capable of detecting underlying bone surface noninvasively through multiple layers of soft tissues, an integration of multiple A-mode ultrasound transducers with a conventional motion tracking system provides a new approach to track the motion of bone segments during dynamic conditions. To demonstrate the technical and clinical feasibilities of this concept, an in vivo experiment was conducted. For this purpose the kinematics of healthy individuals were determined in treadmill walking conditions and stair descending tasks. The results clearly demonstrated the potential of tracking skeletal motion of the lower extremity and measuring six-degrees-of-freedom (6-DOF) tibiofemoral kinematics and related kinematic alterations caused by a variety of gait parameters. It was concluded that this prototyping system has great potential to measure human kinematics in an ambulant, non-radiative, and noninvasive manner.

Keywords

Joint motion tracking A-mode ultrasound Knee Kinematics Lower extremity Gait analysis 

References

  1. 1.
    Ramsey DK, Wretenberg PF (1999) Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint. Clin Biomech 14(9):595–611.  https://doi.org/10.1016/S0268-0033(99)00015-7 CrossRefGoogle Scholar
  2. 2.
    Schilling C, Krüger S, Grupp TM, Duda GN, Blömer W, Rohlmann A (2011) The effect of design parameters of dynamic pedicle screw systems on kinematics and load bearing: an in vitro study. Eur Spine J 20(2):297–307.  https://doi.org/10.1007/s00586-010-1620-6 CrossRefPubMedPubMedCentralGoogle Scholar
  3. 3.
    Simon D. What is “registration” and why is it so important in CAOSGoogle Scholar
  4. 4.
    Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K et al (2001) Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 6(4):195–203.  https://doi.org/10.1002/igs.10011 CrossRefPubMedPubMedCentralGoogle Scholar
  5. 5.
    Anderson KC, Buehler KC, Markel DC (2005) Computer assisted navigation in total knee arthroplasty: comparison with conventional methods. J Arthroplasty 20(7 Suppl 3):132–138.  https://doi.org/10.1016/j.arth.2005.05.009 CrossRefPubMedPubMedCentralGoogle Scholar
  6. 6.
    Mavrogenis AF, Savvidou OD, Mimidis G, Papanastasiou J, Koulalis D, Demertzis N et al (2013) Computer-assisted navigation in orthopedic surgery. Orthopedics 36(8):631–642.  https://doi.org/10.3928/01477447-20130724-10 CrossRefPubMedPubMedCentralGoogle Scholar
  7. 7.
    Kaiser JM, Vignos MF, Kijowski R, Baer G, Thelen DG (2017) Effect of Loading on In Vivo Tibiofemoral and Patellofemoral Kinematics of Healthy and ACL-Reconstructed Knees. Am J Sports Med 45(14):3272.  https://doi.org/10.1177/0363546517724417 CrossRefPubMedPubMedCentralGoogle Scholar
  8. 8.
    Zeng X, Ma L, Lin Z, Huang W, Huang Z, Zhang Y et al (2017) Relationship between Kellgren-Lawrence score and 3D kinematic gait analysis of patients with medial knee osteoarthritis using a new gait system. Sci Rep 7(1):4080.  https://doi.org/10.1038/s41598-017-04390-5 CrossRefPubMedPubMedCentralGoogle Scholar
  9. 9.
    Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT et al (2007) OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng 54(11):1940–1950.  https://doi.org/10.1109/tbme.2007.901024 CrossRefPubMedGoogle Scholar
  10. 10.
    Gerus P, Sartori M, Besier TF, Fregly BJ, Delp SL, Banks SA et al (2013) Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces. J Biomech 46(16):2778–2786.  https://doi.org/10.1016/j.jbiomech.2013.09.005 CrossRefPubMedPubMedCentralGoogle Scholar
  11. 11.
    Fuller J, Liu LJ, Murphy MC, Mann RW (1997) A comparison of lower-extremity skeletal kinematics measured using skin- and pin-mounted markers. Hum Mov Sci 16(2–3):219–242.  https://doi.org/10.1016/S0167-9457(96)00053-X CrossRefGoogle Scholar
  12. 12.
    Richard V, Cappozzo A, Dumas R (2017) Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation. J Biomech.  https://doi.org/10.1016/j.jbiomech.2017.01.030 CrossRefPubMedCentralGoogle Scholar
  13. 13.
    Andersen MS, Benoit DL, Damsgaard M, Ramsey DK, Rasmussen J (2010) Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics. J Biomech 43(2):268–273.  https://doi.org/10.1016/j.jbiomech.2009.08.034 CrossRefPubMedCentralGoogle Scholar
  14. 14.
    Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A (1992) Three-dimensional kinematics of the human knee during walking. J Biomech 25(4):347–357.  https://doi.org/10.1016/0021-9290(92)90254-X CrossRefPubMedPubMedCentralGoogle Scholar
  15. 15.
    Cereatti A, Bonci T, Akbarshahi M, Aminian K, Barre A, Begon M et al (2017) Standardization proposal of soft tissue artefact description for data sharing in human motion measurements. J Biomech.  https://doi.org/10.1016/j.jbiomech.2017.02.004 CrossRefPubMedCentralGoogle Scholar
  16. 16.
    Akbarshahi M, Schache AG, Fernandez JW, Baker R, Banks S, Pandy MG (2010) Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. J Biomech 43(7):1292–1301.  https://doi.org/10.1016/j.jbiomech.2010.01.002 CrossRefPubMedPubMedCentralGoogle Scholar
  17. 17.
    Benoit DL, Ramsey DK, Lamontagne M, Xu L, Wretenberg P, Renström P (2006) Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. Gait Posture 24(2):152–164.  https://doi.org/10.1016/j.gaitpost.2005.04.012 CrossRefPubMedPubMedCentralGoogle Scholar
  18. 18.
    Bonnet V, Richard V, Camomilla V, Venture G, Cappozzo A, Dumas R (2017) Joint kinematics estimation using a multi-body kinematics optimisation and an extended Kalman filter, and embedding a soft tissue artefact model. J Biomech.  https://doi.org/10.1016/j.jbiomech.2017.04.033 CrossRefPubMedCentralGoogle Scholar
  19. 19.
    Cappozzo A, Cappello A, Croce UD, Pensalfini F (1997) Surface-marker cluster design criteria for 3-D bone movement reconstruction. IEEE Trans Biomed Eng 44(12):1165–1174.  https://doi.org/10.1109/10.649988 CrossRefPubMedPubMedCentralGoogle Scholar
  20. 20.
    Andersen MS, Damsgaard M, Rasmussen J (2009) Kinematic analysis of over-determinate biomechanical systems. Comput Methods Biomech Biomed Eng 12(4):371–384.  https://doi.org/10.1080/10255840802459412 CrossRefGoogle Scholar
  21. 21.
    Bonnechère B, Sholukha V, Salvia P, Rooze M, Van Sint Jan S (2015) Physiologically corrected coupled motion during gait analysis using a model-based approach. Gait Posture 41(1):319–322.  https://doi.org/10.1016/j.gaitpost.2014.09.012 CrossRefPubMedPubMedCentralGoogle Scholar
  22. 22.
    Charlton IW, Tate P, Smyth P, Roren L (2004) Repeatability of an optimised lower body model. Gait Posture 20(2):213–221.  https://doi.org/10.1016/j.gaitpost.2003.09.004 CrossRefPubMedPubMedCentralGoogle Scholar
  23. 23.
    Duprey S, Cheze L, Dumas R (2010) Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization. J Biomech 43(14):2858–2862.  https://doi.org/10.1016/j.jbiomech.2010.06.010 CrossRefPubMedPubMedCentralGoogle Scholar
  24. 24.
    Lu TW, O’Connor JJ et al (1999) J Biomech 32(2):129–134.  https://doi.org/10.1016/S0021-9290(98)00158-4 CrossRefPubMedPubMedCentralGoogle Scholar
  25. 25.
    Bingham J, Li G (2006) An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. J Biomech Eng 128(4):588–595.  https://doi.org/10.1115/1.2205865 CrossRefPubMedPubMedCentralGoogle Scholar
  26. 26.
    Baka N, Kaptein BL, Giphart JE, Staring M, de Bruijne M, Lelieveldt BPF et al (2014) Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy. J Biomech 47(1):122–129.  https://doi.org/10.1016/j.jbiomech.2013.09.022 CrossRefPubMedPubMedCentralGoogle Scholar
  27. 27.
    Gray HA, Guan S, Pandy MG (2017) Accuracy of mobile biplane X-ray imaging in measuring 6-degree-of-freedom patellofemoral kinematics during overground gait. J Biomech 57:152–156.  https://doi.org/10.1016/j.jbiomech.2017.04.009 CrossRefPubMedPubMedCentralGoogle Scholar
  28. 28.
    Guan S, Gray HA, Keynejad F, Pandy MG (2016) Mobile biplane x-ray imaging system for measuring 3D dynamic joint motion during overground gait. IEEE Trans Med Imaging 35(1):326–336.  https://doi.org/10.1109/TMI.2015.2473168 CrossRefPubMedPubMedCentralGoogle Scholar
  29. 29.
    List R, Postolka B, Schutz P, Hitz M, Schwilch P, Gerber H et al (2017) A moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent. PLoS One 12(10):e0185952.  https://doi.org/10.1371/journal.pone.0185952 CrossRefPubMedPubMedCentralGoogle Scholar
  30. 30.
    Mazzoli V, Schoormans J, Froeling M, Sprengers AM, Coolen BF, Verdonschot N et al (2017) Accelerated 4D self-gated MRI of tibiofemoral kinematics. NMR Biomed.  https://doi.org/10.1002/nbm.3791 CrossRefGoogle Scholar
  31. 31.
    Clarke EC, Martin JH, d’Entremont AG, Pandy MG, Wilson DR, Herbert RD (2015) A non-invasive, 3D, dynamic MRI method for measuring muscle moment arms in vivo: Demonstration in the human ankle joint and Achilles tendon. Med Eng Phys 37(1):93–99.  https://doi.org/10.1016/j.medengphy.2014.11.003 CrossRefPubMedPubMedCentralGoogle Scholar
  32. 32.
    Kaiser J, Bradford R, Johnson K, Wieben O, Thelen DG (2013) Measurement of 3D tibiofemoral kinematics using volumetric SPGR-VIPR Imaging. Magn Reson Med 69(5):1310–1316.  https://doi.org/10.1002/mrm.24362 CrossRefPubMedPubMedCentralGoogle Scholar
  33. 33.
    Forsberg D, Lindblom M, Quick P, Gauffin H (2016) Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data. Int J Comput Assist Radiol Surg 11(9):1731–1741.  https://doi.org/10.1007/s11548-016-1357-8 CrossRefPubMedPubMedCentralGoogle Scholar
  34. 34.
    Zhao K, Breighner R, Holmes D, Leng S, McCollough C, An K-N (2015) A technique for quantifying wrist motion using four-dimensional computed tomography: approach and validation. J Biomech Eng 137(7):0745011–0745015.  https://doi.org/10.1115/1.4030405 CrossRefGoogle Scholar
  35. 35.
    Smistad E, Falch TL, Bozorgi M, Elster AC, Lindseth F (2015) Medical image segmentation on GPUs – A comprehensive review. Med Image Anal 20(1):1–18.  https://doi.org/10.1016/j.media.2014.10.012 CrossRefPubMedPubMedCentralGoogle Scholar
  36. 36.
    Wein W, Karamalis A, Baumgartner A, Navab N (2015) Automatic bone detection and soft tissue aware ultrasound–CT registration for computer-aided orthopedic surgery. Int J Comput Assist Radiol Surg 10(6):971–979.  https://doi.org/10.1007/s11548-015-1208-z CrossRefPubMedPubMedCentralGoogle Scholar
  37. 37.
    Fieten L, Schmieder K, Engelhardt M, Pasalic L, Radermacher K, Heger S (2009) Fast and accurate registration of cranial CT images with A-mode ultrasound. Int J Comput Assist Radiol Surg 4(3):225–237.  https://doi.org/10.1007/s11548-009-0288-z CrossRefPubMedPubMedCentralGoogle Scholar
  38. 38.
    Talib H, Peterhans M, Garcia J, Styner M, Gonzalez Ballester MA (2011) Information filtering for ultrasound-based real-time registration. IEEE Trans Biomed Eng 58(3):531–540.  https://doi.org/10.1109/TBME.2010.2063703 CrossRefPubMedPubMedCentralGoogle Scholar
  39. 39.
    Otake Y, Armand M, Armiger RS, Kutzer MD, Basafa E, Kazanzides P et al (2012) Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration. IEEE Trans Med Imaging 31(4):948–962.  https://doi.org/10.1109/TMI.2011.2176555 CrossRefPubMedPubMedCentralGoogle Scholar
  40. 40.
    Niu K, Sluiter V, Sprengers A, Homminga J, Verdonschot N (eds) (2017) A novel tibiafemoral kinematics measurement system based on multi-channel a-mode ultrasound system. In: CAOS 2017. 17th annual meeting of the international society for computer assisted orthopaedic surgery; 2017 June 13, EasyChair, AachenGoogle Scholar
  41. 41.
    Miranda DL, Rainbow MJ, Leventhal EL, Crisco JJ, Fleming BC (2010) Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human knee. J Biomech 43(8):1623–1626.  https://doi.org/10.1016/j.jbiomech.2010.01.036 CrossRefPubMedPubMedCentralGoogle Scholar
  42. 42.
    Inc. PPT. VZ4000v technical specifications. http://www.ptiphoenix.com/products/trackers/VZ4000v. Accessed 3 Mar 2017
  43. 43.
    Maurer CR Jr, Maciunas RJ, Fitzpatrick JM (1998) Registration of head CT images to physical space using a weighted combination of points and surfaces. IEEE Trans Med Imaging 17(5):753–761.  https://doi.org/10.1109/42.736031 CrossRefPubMedPubMedCentralGoogle Scholar
  44. 44.
    Besl PJ, McKay HD (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239–256.  https://doi.org/10.1109/34.121791 CrossRefGoogle Scholar
  45. 45.
    Wu G, Cavanagh PR (1995) ISB recommendations for standardization in the reporting of kinematic data. J Biomech 28(10):1257–1261.  https://doi.org/10.1016/0021-9290(95)00017-C CrossRefPubMedPubMedCentralGoogle Scholar
  46. 46.
    Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105(2):136–144CrossRefPubMedCentralGoogle Scholar
  47. 47.
    Mannering N, Young T, Spelman T, Choong PF (2017) Three-dimensional knee kinematic analysis during treadmill gait: Slow imposed speed versus normal self-selected speed. Bone Joint Res 6(8):514–521.  https://doi.org/10.1302/2046-3758.68.bjr-2016-0296.r1 CrossRefPubMedPubMedCentralGoogle Scholar
  48. 48.
    Guan S, Gray HA, Schache AG, Feller J, de Steiger R, Pandy MG (2017) In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty. J Orthop Res 35:1634–1643.  https://doi.org/10.1002/jor.23466 CrossRefPubMedPubMedCentralGoogle Scholar
  49. 49.
    Jia R, Monk P, Murray D, Noble JA, Mellon S (2017) CAT & MAUS: A novel system for true dynamic motion measurement of underlying bony structures with compensation for soft tissue movement. J Biomech.  https://doi.org/10.1016/j.jbiomech.2017.04.015 CrossRefPubMedCentralGoogle Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2018

Authors and Affiliations

  • Kenan Niu
    • 1
  • Victor Sluiter
    • 1
  • Jasper Homminga
    • 1
  • André Sprengers
    • 2
  • Nico Verdonschot
    • 2
  1. 1.Laboratory of Biomechanical Engineering, MIRA InstituteUniversity of TwenteEnschedethe Netherlands
  2. 2.Orthopaedic Research LabRadboud University Medical CenterNijmegenthe Netherlands

Personalised recommendations