Research on the Automatic Detection Technology of the Intelligent Substation Relay Protection Vector

Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 463)

Abstract

This paper introduces the present situation of intelligent substation vector check, and puts forward a protection vector concentrated extract and automatic detection method, including building relevance between bay and logical node of protection vector, building power flow target value and status value database based on the relay protection, reading the status value of relay protection through MMS communication service of station level, and realizing the vector automatic diagnosis based on the target value of power flow.

Keywords

Intelligent substation Protection vector Logical node Power flow Automatic diagnosis 

References

  1. 1.
    GB/T 14285: Technical code for relaying protection and security automatic equipment (2006)Google Scholar
  2. 2.
    DL/T 587: Code for operating management of microprocessor-based relaying protection equipment (2007)Google Scholar
  3. 3.
    DL/T 995: Testing Regulations on Protection and Stability Control Equipment (2006)Google Scholar
  4. 4.
    Xiao, Y., Chang, F.-R.: Operation mode analysis after alteration of electric first and secondary equipment. Hebei Electr. Power 28(3), 4–7 (2009)Google Scholar
  5. 5.
    Deng, J.-Q., Xiang, W.: Research of a flow-through test module and scheme for 500 kV transformer. Relay 36(7), 92–95 (2008)Google Scholar
  6. 6.
    IEC 61850-5: Communication networks and systems in substations Part 5: Communication requirements for functions and device models (2003)Google Scholar
  7. 7.
    IEC 61850-7-2: Communication networks and systems in substations Part 7-2: Basic communication structure for substation and feeder equipment Abstract communication service interfaces (2003)Google Scholar
  8. 8.
    IEC 61850-6: Communication networks and systems in substations Part 6: Configuration description language for communication in electrical substation related to IEDs (2003)Google Scholar
  9. 9.
    IEC 61850-8-1: Communication networks and systems in substations Part 8-1: Specific Communication Service Mapping (SCSM) mapping to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 (2004)Google Scholar
  10. 10.
    Lin, Z.-M., Yang, F.-P., Yu, Y.: Analyzing and implementation of mapping between IEC61850 and MMS. Relay 35(2), 64–67 (2007)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  1. 1.The Electric Power Research Institute of State Grid HEBEI Electric Power CompanyShijiazhuangChina
  2. 2.State Grid HEBEI Electric Power CompanyShijiazhuangChina

Personalised recommendations