Contactless Respiration Monitoring in Real-Time via a Video Camera

  • Conference paper
  • First Online:
EMBEC & NBC 2017 (EMBEC 2017, NBC 2017)

Abstract

Until today, vital signs monitoring in neonatal intensive care units (NICUs) is based on wired sensors, known to cause discomfort and false alarms. In view of overcoming such issues we investigate a contactless method for respiration monitoring by means of a simple video camera. Unlike many other solutions proposed in the literature, our approach makes use of a motion estimation with low computational complexity which facilitates a real-time implementation. To do so, the input image is split into blocks, for each of which motion is estimated. Thereafter, these block motions are classified according to their likelihood to contain true respiratory activity, enabling an automatic region of interest detection. Aside from the respiratory rate (RR) our algorithm also computes a quality index, representing the confidence of the given RR. The proposed approach was tested and evaluated on 16 healthy adults, both during illuminated and dark conditions, using a color or near-infrared camera, respectively. On more than 2 hours of recording, Bland-Altman analysis reveals an error of 0.2 ± 2.3 bpm (breaths-per-minute) when compared to the reference measure, a thoracic strain gauge belt. Our analysis further indicates that – independent of light or dark conditions – the near-infrared camera alone is sufficient to achieve satisfying results. These findings pave the way towards a simple, low-cost and contactless RR monitoring. While currently only tested on healthy adults, future work includes the evaluation of this approach in clinical scenarios, such as NICUs in particular.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Daw, W., Kingshott, R., Saatchi, R., et al.: Medical Devices for Measuring Respiratory Re in Children Journal of Advances in Biomedical Engineering and Technology. 3, 21–27 (2016)

    Google Scholar 

  2. AL-Khalidi F Q, Saatchi R, Burke D, Elphick H, Tan S. Respiration rate monitoring methods: A review Pediatric Pulmonology. 2011;46:523–529

    Google Scholar 

  3. Hafner, N., Mostafanezhad, I., Lubecke, V.M., Boric-Lubecke, O., Host-Madsen, A.: Non-contact cardiopulmonary sensing with a baby monitor in IEEE EMBS 2007, 2300–2302 (2007)

    Google Scholar 

  4. Min, S.D., Yoon, D.J., Yoon, S.W., Yun, Y.H., Lee, M.: A study on a non-contacting respiration signal monitoring system using Doppler ultrasound Medical & biological engineering & computing. 45, 1113–1119 (2007)

    Google Scholar 

  5. Abbas, K., Heimann, K., Jergus, K., Orlikowsky, T., Leonhardt, S.: Neonatal non-contact respiratory monitoring based on real-time infrared thermography Biomedical Engineering Online. 10, 93 (2011)

    Google Scholar 

  6. Murthy, R., Pavlidis, I., Tsiamyrtzis, P.: Touchless monitoring of breathing function in IEEE IEMBS 2004(1), 1196–1199 (2004)

    Google Scholar 

  7. Bartula, M., Tigges, T., Muehlsteff, J.: Camera-based system for contactless monitoring of respiration in IEEE EMBC 2672–2675, 2013 (2013)

    Google Scholar 

  8. Janssen, R., Wang, W., Moço, A., Haan, G.: Video-based respiration monitoring with automatic region of interest detection Physiological Measurement. 37, 100 (2015)

    Google Scholar 

  9. Koolen, N., Decroupet, O., Dereymaekerand, Jansen A., K, et al.: Automated Respiration Detection from Neonatal Video Data. ICPRAM(2):164–169 2015

    Google Scholar 

  10. Tveit, D.M., Engan, K., Austvoll, I., Meinich-Bache, Ø.: Motion based detection of respiration rate in infants using video in IEEE ICIP 2016, 1225–1229 (2016)

    Google Scholar 

  11. Tan, K.S., Saatchi, R., Elphick, H., Burke, D.: Real-time vision based respiration monitoring system in IEEE CSNDSP 2010, 770–774 (2010)

    Google Scholar 

  12. Lee Won Kyu: Yoon Heenam, Han Chungmin, Joo Kwang Min, Park Kwang Suk. Physiological Signal Monitoring Bed for Infants Based on Load-Cell Sensors Sensors. 16, 409 (2016)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Fabian Braun .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Braun, F., Lemkaddem, A., Moser, V., Dasen, S., Grossenbacher, O., Bertschi, M. (2018). Contactless Respiration Monitoring in Real-Time via a Video Camera. In: Eskola, H., Väisänen, O., Viik, J., Hyttinen, J. (eds) EMBEC & NBC 2017. EMBEC NBC 2017 2017. IFMBE Proceedings, vol 65. Springer, Singapore. https://doi.org/10.1007/978-981-10-5122-7_142

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-5122-7_142

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-5121-0

  • Online ISBN: 978-981-10-5122-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics