“E All’ottavo Giorno, Dio Creò La Citometria … and on the 8th Day, God Created Cytometry”
Abstract
Flow cytometry has been available for about 50 years, but the core technology has changed very little. This constancy achieves two things: it makes the technology stronger as it has long-term development, but it also means that many applications may be a little stale. This chapter is an attempt to outline how the technology evolved into its current form and to identify the key changes that occurred along the way. While not every aspect of the evolution is documented herein, it is an attempt at framing the discoveries within the context of flow cytometry–specific demands. Flow cytometry evolved slowly for the first 15 years and then rapidly developed into one of the most significant cellular analysis technologies available to cell biologists.
Keywords
Cytometry history Cytometry invention Ink-jet printing Cell sorting Multicolor phenotyping Monoclonal antibodiesReferences
- 1.Hooke R (1665) Micrographia. Octavo, Republished in 1998 as CDrom edition. 1891788027Google Scholar
- 2.Robert H (1665) Micrographica. Royal Society, LondonGoogle Scholar
- 3.Feulgen R, Rossenback H (1924) Mikroskopisch-chemischer Nachweis einer Nucleinsäure vom Typus der Thymonucleinsäure und die darauf beruhende elektive Färbungvon Zellkernen in mikroskopischen Präparaten. Hoppe Seyler ZPhysiolChem 135Google Scholar
- 4.Moldavan A (1934) Photo-electric technique for the counting of microscopical cells. Science 80:188–189Google Scholar
- 5.Gucker FT Jr, O’Konski CT, Pickard HB, Pitts JN Jr (1947) A photoelectronic counter for colloidal particles. J Am Chem Soc 69:2422–2431Google Scholar
- 6.Gucker FT Jr, O’Konski CT (1949) Electronic methods of counting aerosol particles. Chem Rev 44:373–388Google Scholar
- 7.Caspersson TO (1936) Uber den chemischen Aufbau der Strukturen des Zellkernes. SkandArchPhysiol 73Google Scholar
- 8.Caspersson TO (1964) Quantitative cytochemical studies on normal, malignant, premalignant and atypical cell populations from the human uterine cervix. Acta Cytologica 8:45Google Scholar
- 9.Coons AH, Creech HJ, Jones RN (1941) Immunological properties of an antibody containing a fluorescent group. Proc Soc Exp Biol Med 47:200–202Google Scholar
- 10.Coons AH, Kaplan MH (1950) Localization of antigen in tissue cells. II. Improvements in a method for the detection of antigen by means of fluorescent antibody. J Exp Med 91:1–13Google Scholar
- 11.Papanicolaou GN, Traut R (1941) The diagnostic value of vaginal smears in carcinoma of the uterus. Am J Obstet Gynecol 42:193–206Google Scholar
- 12.Caspersson TO (1941) Ribonucleic acids and the synthesis of cellular proteins. Naturwiss 28:33Google Scholar
- 13.Caspersson TO (1950) Cell growth and cell function. A cytochemical study. W.W. Norton & Company, New YorkGoogle Scholar
- 14.Avery OT, McCarty M, MacLeod M (1944) Studies on the chemical nature of the substance inducing transformation of pneumococcal types. Induction of transformation by a desoxyribonucleic acid fraction isolated from Pneumococcus type III. J Exp Med 79:137–158Google Scholar
- 15.Watson JD, Crick FHC (1953) Molecular structure of nucleic acids; a structure for deoxyribose nucleic acid. Nature 171:737–738Google Scholar
- 16.Coulter WH (1953) Means for counting particles suspended in a fluid.Google Scholar
- 17.Crosland-Taylor PJ (1953) A device for counting small particles suspended in fluid through a tube. Nature 171:37–38Google Scholar
- 18.Crosland-Taylor PJ, Stewart JW, Haggis G (1958) An electronic blood-cell-counting machine. Blood 13:398Google Scholar
- 19.Lushbaugh CC, Basmann NJ, Glascock B (1962) Electronic measurements of cellular Volumes II. Frequency distribution of erythrocyte volumes. Blood 20:241–248Google Scholar
- 20.Lushbaugh CC, Hale DB (1963) Electronic measurement of cellular Volume VII. Biologic evidence for two volumetrically distinct subpopulations of red blood cells, in annual report biological and medical research group (H-4) of the health division, July 1962 through June 1963. Los Alamos Scientific Laboratory of the University of California, p 270–278Google Scholar
- 21.Sweet RG (1965) High frequency recording with electrostatically deflected ink jets. Rev Sci Instru 36:131–136Google Scholar
- 22.Fulwyler MJ (1965) Electronic separation of biological cells by volume. Science 150:910–911Google Scholar
- 23.Fulwyler MJ (2005) Mack Fulwyler in his own words. Interview by Robinson JP, Kondratas RA. CytometryPart A. J Int Soc Anal Cytol 67:61–67Google Scholar
- 24.Kamentsky LA (1958) Spatially oriented character recognition. Bell Telephone LabsGoogle Scholar
- 25.Kamentsky LA, Liu CN (1963) Computer-automated design of multifont print recognition logic. J Res Dev 7:2–13Google Scholar
- 26.Kamentsky LA, Derman H, Melamed MR (1963) Ultraviolet absorption in epidermoid cancer cells. Science 142:1580–1583Google Scholar
- 27.Kamentsky LA, Melamed MR, Derman H (1965) Spectrophotometer: new instrument for ultrarapid cell analysis. Science 150:630–631Google Scholar
- 28.Dittrich W, Gohde W (1969) Impulse fluorometry of single cells in suspension. Z Naturforsch B 24:360–361Google Scholar
- 29.Kîhler G, Milstein C (1975) Continuous cultures of fused cells secreting antibody of predefined specificity. Nature 256:495–497Google Scholar
- 30.Milstein C (1999) The hybridoma revolution: an offshoot of basic research. Bioessays 21:966–973Google Scholar
- 31.Hulett HR, Bonner WA, Barrett J, Herzenberg LA (1969) Cell sorting: automated separation of mammalian cells as a function of intracellular fluorescence. Science 166:747–749Google Scholar
- 32.Kamentsky LA, Melamed MR (1967) Spectrophotometric cell sorter. Science 156:1364–1365Google Scholar
- 33.Bonner WA, Hulett HR, Sweet RG, Herzenberg LA (1972) Fluorescence activated cell sorting. Review of Scientific Instruments 43:404–409Google Scholar
- 34.Schwartz A (1988) Calibration method for flow cytometry using fluorescent microbeads and synthesis thereof, U.P. Office, Editor. USAGoogle Scholar
- 35.Poncelet P, Carayon P (1985) Cytofluorometric quantification of cell-surface antigens by indirect immunofluorescence using monoclonal antibodies. J Immunol Methods 85:65–74Google Scholar
- 36.Schwartz A (1990) A method for calibrating a flow cytometer of fluorescence microscope for quantitating binding antibodies on a selected sample, and microbead calibration kit thereof, U.P. Office, Editor, Carribean Microparticle Corporation, USAGoogle Scholar
- 37.Schwartz A, Gaigalas AK, Wang L, Marti GE, Vogt RF, Fernandez-Repollet E (2004) Formalization of the MESF unit of fluorescence intensity. Cytometry B Clin Cytom 57:1–6Google Scholar
- 38.Hiddemann W, Schumann J, Andreeff M, Barlogie B, Herman CJ, Leif RC, Mayall BH, Murphy RF, Sandberg AA (1984) Convention on nomenclature for DNA cytometry. Committee on nomenclature, Society for Analytical Cytology. Cancer Genet Cytogenet 13:181–183Google Scholar
- 39.Murphy RF, Chused TM (1984) A proposal for a flow cytometric data file standard. Cytometry 5:553–555Google Scholar
- 40.Dean PN, Bagwell CB, Lindmo T, Murphy RF, Salzman GC (1990) Data file standard for flow cytometry. Cytometry 11:323–332. doi: 10.1002/(SICI)1097-0320(19970601)28:2<118:AID-CYTO3>3.0.CO;2-B CrossRefGoogle Scholar
- 41.Spidlen J, Gentleman RC, Haaland PD, Langille M, Le Meur N, Ochs MF, Schmitt C, Smith CA, Treister AS, Brinkman RR (2006) Data standards for flow cytometry. OMICS 10:209–214Google Scholar
- 42.Spidlen J, Moore W, Parks D, Goldberg M, Bray C, Bierre P, Gorombey P, Hyun B, Hubbard M, Lange S, Lefebvre R, Leif R, Novo D, Ostruszka L, Treister A, Wood J, Murphy RF, Roederer M, Sudar D, Zigon R, Brinkman RR (2010) Data file standard for flow cytometry, version FCS 3.1. CytometryPart A. J Int Soc Anal Cytol 77:97–100Google Scholar
- 43.Dytch HE, Bibbo M, Puls JH, Bartels PH, Wied GL (1986) Software design for an inexpensive, practical, microcomputer-based DNA cytometry system. Anal Quant Cytol Histol 8:8–18Google Scholar
- 44.Keij JF, Griffioen AW, The TH, Rijkers GT (1989) INCA: Software for Consort 30 analysis of flow cytometric calcium determinations. Cytometry 10:814–817Google Scholar
- 45.Redelman D (1991) MS-DOS software to analyze flow cytometry data. Cytometry Suppl 5:136–136Google Scholar
- 46.Loken MR, Lanier LL (1984) Three-color immunofluorescence analysis of Leu antigens on human peripheral blood using two lasers on a fluorescence-activated cell sorter. Cytometry 5:151–158. doi: 10.1002/cyto.990050209 CrossRefGoogle Scholar
- 47.Godavarti M, Rodriguez JJ, Yopp TA, Lambert GM, Galbraith DW (1996) Automated particle classification based on digital acquisition and analysis of flow cytometric pulse waveforms. Cytometry 24:330–339Google Scholar
- 48.Leary JF (2001) High-speed cell sorting. Curr Protoc Cytom Chapter 1:Unit 1–7. doi: 10.1002/0471142956.cy0107s01
- 49.Shapiro HM (1985) Practical flow cytometry. Alan R. Liss, New YorkGoogle Scholar
- 50.Shapiro HM (1988) Practical flow cytometry, vol 2. Alan R. Liss Inc., New YorkGoogle Scholar
- 51.Berners-Lee T, Secret A, Manning G (1993) The virtual library. s.n., S.lGoogle Scholar
- 52.Berners-Lee T, Fischetti M (1999) Weaving the Web: the original design and ultimate destiny of the world wide web by its inventor. 1st edn. HarperSanFrancisco, San Francisco. xi, p 226Google Scholar
- 53.Berners-Lee T (2006) A framework for web science. Now, Boston. ix, p 134Google Scholar
- 54.Robinson JP, Roederer M (2015) History of science. Flow cytometry strikes gold. Science 350:739–740. doi: 10.1126/science.aad6770 CrossRefGoogle Scholar
- 55.Yamamoto M, Robinson JP (2014) Scanning flow cytometerGoogle Scholar
- 56.Jacobs KM, Lu JQ, Hu XH (2009) Development of a diffraction imaging flow cytometer. Opt Lett 34:2985–2987Google Scholar
- 57.McFarlin BK, Williams RR, Venable AS, Dwyer KC, Haviland DL (2013) Image-based cytometry reveals three distinct subsets of activated granulocytes based on phagocytosis and oxidative burst. Cytometry A 83:745–751. doi: 10.1002/cyto.a.22330 CrossRefGoogle Scholar
- 58.Zhang C, Huang K-C, Rajwa B, Li J, Yang S, Lin H, C-s Liao, Eakins G, Kuang S, Patsekin V, Robinson JP, Cheng J-X (2017) Stimulated Raman scattering flow cytometry for label-free single-particle analysis. Optica 4:103–109. doi: 10.1364/OPTICA.4.000103 CrossRefGoogle Scholar
- 59.Bendall SC, Nolan GP, Roederer M, Chattopadhyay PK (2012) A deep profiler’s guide to cytometry. Trends Immunol 33:323–332. doi: 10.1016/j.it.2012.02.010 CrossRefGoogle Scholar
- 60.Bodenmiller B, Zunder ER, Finck R, Chen TJ, Savig ES, Bruggner RV, Simonds EF, Bendall SC, Sachs K, Krutzik PO, Nolan GP (2012) Multiplexed mass cytometry profiling of cellular states perturbed by small-molecule regulators. Nat Biotechnol 30:858–867. doi: 10.1038/nbt.2317 CrossRefGoogle Scholar
- 61.Qiu P, Simonds EF, Bendall SC, Gibbs KD Jr, Bruggner RV, Linderman MD, Sachs K, Nolan GP, Plevritis SK (2011) Extracting a cellular hierarchy from high-dimensional cytometry data with SPADE. Nature BiotechnologyGoogle Scholar