Practical cardiac pacing

  • E. J. Perrins
Part of the Current Status of Clinical Cardiology book series (CSOCC, volume 6)

Abstract

In this chapter only cardiac pacemakers used for the treatment of bradycardias will be considered. Approximately 10 000 pacemaker implants are performed in the UK each year, which represents approx. 160 implants per million population. This contrasts with considerably higher rates in many other developed countries (USA, Canada and West Germany) of up to 500 per million1. In this country this almost certainly represents under-diagnosis and referral, particularly of patients suffering from sick sinus syndrome and carotid sinus syndrome.

Keywords

Refractory Period Ventricular Pace Sick Sinus Syndrome Output Circuit Dual Chamber 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Feruglio, G. A. Steinbach K. (1983) World survey on cardiac pacing. In Steinbach et al (ed.) Cardiac Pacing, pp. 953 – 68. ( Darmstadt: Steinkopff )Google Scholar
  2. Adams, R. (1827). Irregularity of breathing and remarkable slowness of pulse. Dublin Hospital Report, 4, 396Google Scholar
  3. Stokes, W. (1846). Observations on some cases of permanently slow pulse. Dublin Q. J. Med. Soc.2, 73Google Scholar
  4. Sutton, R. and Perrins, E.J. (1979). Neurological manifestations of the sick sinus syndrome. In Busse, E. (ed.) Cerebral Manifestations of Episodic Cardiacdysrhythmias. pp. 174 – 82. ( Amsterdam: Excerpta Medica )Google Scholar
  5. Perrins, E.J. and Morley, C. A. (1985). The pathophysiology of carotid sinus syndrome. In Gomez, F.P. (ed.) Cardiac Pacing, pp. 200 – 13. ( Madrid: Growz )Google Scholar
  6. Tarjan, p. (1973). Engineering aspects of implantable cardiac pacemakers. In. Samet, P. (ed) Cardiac Pacingp. 47. (New York: Grune and Stratton)Google Scholar
  7. Kruse, I. et al (1982). A comparison of the acute and long term effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing. Circulation 65, 846– 55Google Scholar
  8. Perrins, E.J. Morley, C. A. Chan, S. L. and Sutton, R. (1982). A randomised controlled trial of physiological and ventricular pacing. Br. Heart J., 50, 112 – 17Google Scholar
  9. Mond, H. and Sloman, J. (1980). The small tined ventricular lead. Absence of displacement. Pace, 3, 171 – 7PubMedGoogle Scholar
  10. Messenger, J., Castellanet, M.J. and Stephenson, N. L. (1982). New permanent endocardial atrial J lead: implantation techniques and clinical performance. Pace, 5, 767 – 72Google Scholar
  11. Kertes, P., Mond, H., Sloman, G. et al(1983). Comparison of lead complications with polyurethane tines, silicone rubber tined and wedge tipped leads. Clinical experience with 822 endocardial ventricular leads. Pace, 6, 957 – 62PubMedGoogle Scholar
  12. Ausubel, K. and Furman, S. (1985). The pacemaker syndrome. Ann. Intern. Med., 103, 420 – 9PubMedGoogle Scholar
  13. Alicandri, C., Fouad, F. M., Tarazi, R. C., Castle, L. and Mourant, V. (1978). Three cases of hypotension and syncope with ventricular pacing. Possible role of atrial reflexes. Am. J. Cardiol., 42, 137 – 42PubMedCrossRefGoogle Scholar
  14. Morley, C.A., Perrins, E.J., Grant, P., Chan, S.L., McBrien, D. and Sutton, R. (1982). Carotid sinus syncope treated by pacing. Analysis of persistent symptoms and the role of atrioventricular sequential pacing. Br. Heart J., 47, 411 – 18PubMedCrossRefGoogle Scholar

Copyright information

© Kluwer Academic Publishers 1988

Authors and Affiliations

  • E. J. Perrins

There are no affiliations available

Personalised recommendations