Non destructive assessment of concrete structures: usual combinations of techniques

Chapter
Part of the RILEM State of the Art Reports book series (RILEM State Art Reports, volume 1)

Abstract

Condition assessment of building materials is critical when reassessing existing structures, since material ageing can result in performance loss, degradation of safety, and maintenance costs. For these reasons, the use of non destructive testing (NDT) has become more common to assess the condition of existing reinforced concrete structures.

Keywords

Electrical Resistivity Concrete Structure Infrared Thermography Ultrasonic Pulse Velocity Strength Assessment 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. Alt D., Meggers D. (1996) Determination of bridge deck subsurface anomalies using infrared thermography and ground penetrating radar, Kansas DOT, Report FHWA-KS-96-2, 18 p.Google Scholar
  2. Arndt R.W., Jalinoos F., Cui J., Huston D. (2010) Periodic NDE for bridge maintenance, Structural Faults and Repair, Edimburgh, june 2010.Google Scholar
  3. Balayssac J.P. (2008) SENSO: a French project for the evaluation of concrete structures by combining non-destructive methods, Sacomatis, RILEM conf., 1-2/9/2008, Varenna, It.Google Scholar
  4. Breysse D. (2008) Condition assessment of concrete, masonry and timber structures and the role of water: how far the problem is similar ?, SACoMaTiS Int. RILEM Conf., 1-2 sept. 2008, Varenna, Como lake, Italy.Google Scholar
  5. Breysse D. (2010) Overview of deterioration processes, in Non-Destructive Evaluation of Reinforced Concrete Structures, ed. C. Maierhofer, H.W. Reinhardt, Bertram publ.Google Scholar
  6. Breysse D., Abraham O. (2005) Guide méthodologique de l’évaluation non-destructive des ouvrages en béton armé, Presses ENPC, Paris, 550 pages.Google Scholar
  7. Bungey J.H., Millard S.G. (1996) Testing of concrete in structures, Blackie Acd. and Prof., 3rd edition, 286 p.Google Scholar
  8. De Bold R., Giannopoulos A., Forde M.C., Pareemamun K. (2010) Interpretation of NDT of thick concrete, Structural Faults and Repair, Edimburgh, june 2010.Google Scholar
  9. De Lorenzis L., Nanni A. (2004) Int. workshop on preservation of historical structures with FRP composites, Final Report, NSF.Google Scholar
  10. Dérobert X., Garnier V., François D., Lataste J.F., Laurens S. (2005) Complémentarité des méthodes d’END, in Guide méthodologique de l’évaluation non destructive des ouvrages en béton armé, ed. Breysse D., Abraham O., Presses ENPC, Paris, 550 pages.Google Scholar
  11. Dilek U. (2006) Dynamic elastic Young’s modulus of concrete disks in validation of stress wave based non-destructive testing technique results, 85th TRB Annual meeting, 22-26 jan. 2006.Google Scholar
  12. EN 13791 (2007) Assessment of in-situ compressive strength in structures and precast concrete, CEN, Brussels, 28 p.Google Scholar
  13. FHWA (2002) Corrosion Costs and Preventive Strategies in the United States, Report from CC Technologies Laboratories, Inc. (Dublin, Ohio), for FHWA and NACE.Google Scholar
  14. Gardei A., Mittag K., Wiggenhauser H., Ripke B., Jovanovic M. (2003) Inspection of concrete-embedded tracks process development for the quality assurance of concrete-embedded tracks using non-destructive testing methods, NDT-CE, conf., Berlin.Google Scholar
  15. Gehlen C., Dauberschmidt C., Nürnberger U. (2006) Condition control of existing structures by performance testing, Otto-Graf-Journal, 17, 19-44.Google Scholar
  16. Gucunski N., Romero F., Kruschwitz S., Feldmann R. (2010) Comparative study of bridge deck deterioration detection and characterization by multiple NDE methods, Structural Faults and Repair, Edimburgh, june 2010.Google Scholar
  17. IAEA (2002) Guidebook on non-destructive testing of concrete structures, Training course series 17, International Atomic Energy Agency.Google Scholar
  18. ICRI (2009) Nondestructive evaluation (NDE) methods for condition assessment, repair, and performance monitoring of concrete structures, ICRI Guideline.Google Scholar
  19. Klysz G., Balayssac J.P., Derobert X., Aubagnac C. (2003) Evaluation of cover concrete by ­coupling some non-destructive etchniques – Contribution of in-situ measurements, NDT-CE conf., Berlin.Google Scholar
  20. Lataste J.F., Abraham O., Breysse D., Sirieix C (2003) Sensitivity to crack parameters of two non-destructive techniques: electrical resistivity and acoustic methods, NDT-CE conf., Berlin.Google Scholar
  21. Lataste J.F., Breysse D., Sirieix C., Naar S.. (2005) Electrical resistivity measurements on various concretes submitted to marine atmosphere, ICCRC conf., Moscow, 5-9/09/2005.Google Scholar
  22. Maierhofer C., Bink A., Röllig M., Wiggenhauser H. (2002) Transient thermography for structural investigation of concrete and composites in the near surface region, Infrared Physics and Technology, 43, 271-278.CrossRefGoogle Scholar
  23. Maierhofer C., Krause M., Wiggenhauser H. (1998) Non-destructive investigation of sluices using radar and ultrasonic impulse echo, NDT&E Int., 31, 6, 421-427.CrossRefGoogle Scholar
  24. Malhotra, V.M. (1981) Rebound, penetration resistance and pulse velocity tests for testing in place, The Aberdeen Group.Google Scholar
  25. Maser K.R., Holland T.J., Roberts R., Popovics J. (2003) Technology for quality insurance of new pavement thickness, NDT-CE conf. Berlin.Google Scholar
  26. Naar S., Sirieix C., Breysse D., Dérobert X. (2005) Assessment of water saturation rate in a reinforced concrete structures: non-destructive testing of Tarbes’ precast duct, ICCRC conf., Moscow, 5-9/09/2005.Google Scholar
  27. OECD Nuclear Energy Agency (1998) Development priorities for Non-Destructive examination of concrete structures in nuclear plant, Nuclear Safety, NEA/CSNI/R(98) 6, 25-39.Google Scholar
  28. Parthasarathy S., Murthy S.G.N., Sangoju B., Wiggenhauser H., Ravisankar K., Iyer. N.G., Lakshmanan N. (2009) Application of radar and ultrasonic pulse echo for testing concrete structures, NDTCE’09, Nantes, 30 june-3 july 2009.Google Scholar
  29. Pina Santos C., Matias L., Magalhaes A.C., Veiga M.R. (2003) Application of thermography and ultrasounds for wall anomalies diagnosis. A laboratory research study, NDT-CE conf., Berlin.Google Scholar
  30. Rivard P., Naar S., Sbartai M.Z., Fournier B. (2005) Couplage de méthodes non destructives pour l’évaluation de l’endommagement du béton, 12th Conf. on Recherche Québécoise sur les Ouvrages d’Art, 10-11/05/2005, Univ. Laval, Quebec.Google Scholar
  31. Romanescu C., Ionescu C., Scinteie R. (2009) The Romanian road administration experience in the field of NDT for bridges, NDTCE’09, Nantes, 30 june-3 july 2009.Google Scholar
  32. Scott M., Rezaizadeh A., Delahaza A., Santos C., Moore M., Graybeale B., Washer G. (2003) A comparison of nondestructive evaluation methods for bridge deck assessment, NDT&E Int., 36, 4, 245-255.CrossRefGoogle Scholar
  33. Shaw P., Xu A. (1998) Assessment of the deterioration of concrete in nuclear power plants – causes, effects and investigative methods, NDTnet, 3, 2.Google Scholar
  34. Sirieix C., Defer D. (2005) Méthodes thermiques, in : D. Breysse, O. Abraham (Eds), Guide méthodologique de l’évaluation non destructive des ouvrages en béton armé, Presses ENPC, Paris, 550 pages.Google Scholar
  35. Sirieix C., Lataste J.F., Breysse D., Naar S., Dérobert X. (2007) Comparison of nondestructive testing: Infrared thermography, electrical resistivity and capacity methods for assessing a reinforced concrete structure, J. Building Appraisal, 3, 1, 77-88.CrossRefGoogle Scholar
  36. Uemoto T. (2000) Maintenance of concrete structure and applications of non-destructive inspection in Japan, in Proc. of Non-Destructive testing in Civil Engineering, Elsevier, 1-11.Google Scholar
  37. Valluzzi M.R., Grinzato E., Pellegrino C., Modena C. (2009) IR thermography for interface analysis of FRP laminates externally bonded to RC beams, Mat. Str. 42, 25-34.CrossRefGoogle Scholar
  38. Weise F., Pirskawetz S., Meng B. (2008), Application of innovative testing methods for the quasi non-destructive assessment of the material condition in hydraulic engineering structures, Sacomatis conf., Varenna, 1-2/9/2008.Google Scholar
  39. Wolsiefer J.T. (1991) Silica fume concrete: a solution to steel reinforcement corrosion in concrete, Proc. 2nd Canmet/ACI Int. Conf. On durability of concrete, pp. 527-553, ACI, Farmington Hills, MI.Google Scholar
  40. Yong Hao Z., Kee Ee Ng. (2003) Evaluation of concrete structures by advances nondestructive test methods – impact echo, impulse response test and radar survey, NDT-CE conf., Berlin.Google Scholar

Copyright information

© RILEM 2012

Authors and Affiliations

  1. 1.I2M, GCE (Civil and Environmental Engineering Department)University Bordeaux 1TalenceFrance

Personalised recommendations