The structural behaviour of reinforced beams strengthened in flexure with externally bonded FRP (Fibre Reinforced Polymer) reinforcement has been extensively investigated with respect to isostatic beams. Design methods are given in guidelines and standards, and failure modes are described. However, limited information is available on the behaviour of continuous beams, strengthened with composite reinforcement. For flexural strengthening of a 2-span continuous beam, the FRP reinforcement can be applied on top of the central support, at the bottom-side of the two spans or at both locations. By means of an analytical study, the non-linear behaviour of this type of beam is investigated. The failure modes are studied and it is verified to which degree moment redistribution is still present when applying this strengthening technique which makes use of a linear elastic polymeric material.

Keywords

Fibre Reinforce Polymer Plastic Hinge Reinforcement Ratio Flexural Rigidity Continuous Beam 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Notes

Acknowledgements

The authors would like to thank the Fund for Scientific Research in Flanders (FWO) for the financial support.

References

  1. ACI (2002) Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures, ACI 440.2R-02. American Concrete Institute, Farmington HillsGoogle Scholar
  2. Chen JF, Yuan H, Teng JG (2007) Debonding failure along a softening FRP-to concrete interface between two adjacent cracks in concrete members. Eng Struct 29(2):259–270CrossRefGoogle Scholar
  3. fib (2001) Externally bonded FRP reinforcement for RC structures. International federation for structural concrete. fib bulletin 14, Lausanne, 138 ppGoogle Scholar
  4. Holzenkämpfer P (1994) Ingenieurmodelle des Verbunds geklebter Bewehrung fur Betonbauteile. Dissertation, TU Braunschweig (In German), p 214Google Scholar
  5. Matthys S (2000) Structural behaviour and design of concrete members strengthened with externally bonded FRP reinforcement. PhD thesis, Department of Structural Engineering, Ghent University, Ghent, p 345Google Scholar
  6. Nanni A (1993) Fibre-Reinforced-Plastic (FRP) reinforcement for concrete structures: properties and applications, vol 42. Developments in Civil Engineering, Amsterdam, 450 ppGoogle Scholar
  7. NBN-EN-1504-5 (2005) Products and systems for the protection and repair of concrete structures – definitions, requirements, quality control and evaluation of conformity – part 5: concrete injection  =  EN 1504–5:2004Google Scholar
  8. Oller E, Cobo D, Mari AR (2007) A new design proposal to prevent failure in beams strengthened by plate debonding. Proceedings, 8th international symposium on fibre reinforced polymer reinforcement for concrete structures (FRPRCS-8), Patras, July 2007Google Scholar
  9. Teng JG et al (2003) Intermediate crack-induced debonding in RC beams and slabs. Constr Build Mater 17(6–7):447–462CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media B.V. 2012

Authors and Affiliations

  • Pieter Desnerck
    • 1
  • Lander Vasseur
    • 2
  • Stijn Matthys
    • 1
  • Luc Taerwe
    • 1
  1. 1.Department of Structural Engineering, Magnel Laboratory for Concrete ResearchGhent UniversityZwijnaardeBelgium
  2. 2.ECC NV BelgiumAntwerpBelgium

Personalised recommendations