Abstract

Small deep seated tumors constitute a surgical problem. They are often difficult to find with conventional techniques and the amount of brain tissue which must be destroyed to reach the tumor may be fairly large. Ideally they should be treated stereotactically, but it is difficult to create a stereotactic lesion, which is sufficiently large to cover the tumor. The present communication describes a method to use stereotactic cryosurgery. The procedure was done in the CT-scanner in order to make it possible to monitor the size of the lesion intraoperatively.

Keywords

Stereotactic cryosurgery CT scan 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Reference

  1. 1.
    Boëthius, J., Bergström, M., Greitz, T., Stereotactic computerized tomography with a GE 8800 Scanner. J. Neurosurg. 52 (1980), 794–800PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 1984

Authors and Affiliations

  • J. Boëthius
    • 1
  • T. Greitz
    • 2
  • R. Kuylenstierna
    • 3
  • M. Lagerkranser
    • 4
  • P. G. Lundquist
    • 3
  • T. Ribbe
    • 5
  • H. Wiksell
    • 6
  1. 1.Departments of NeurosurgeryKarolinska InstitutetStockholmSweden
  2. 2.Departments of NeuroradiologyKarolinska InstitutetStockholmSweden
  3. 3.Departments of OtorhinolaryngologyKarolinska InstitutetStockholmSweden
  4. 4.Departments of AnaestesiologyKarolinska InstitutetStockholmSweden
  5. 5.Departments of Medical EngineeringKarolinska InstitutetStockholmSweden
  6. 6.The Royal Technical HighschoolStockholmSweden

Personalised recommendations