Abstract

The objective of all quality assurance measures in laboratory medicine is to produce a proper diagnosis based on conclusive findings. Thereupon rests the foundation of optimal treatment for the patient. Conversely, this means for both laboratories and POCT users a paradigm shift from quality control of analyses to comprehensive quality management. This objective can only be achieved if the overall diagnostic process is calculated into the equation; this process extends from the correct patient-focused ordering of tests for the disease-relevant analytes to the correct interpretation of the analysis results aimed at rendering the proper diagnosis and monitoring the therapy based on that diagnosis. In POCT, the pre- and post-analytical phases depend both on the analytes to be tested as well as on the device used. Several overriding principles shall be addressed below.

References

  1. 1.
    Bundesärztekammer (German Medical Association), Instand e.V. (2015) Guidelines of the German Medical Association on quality assurance in medical laboratory testing. GMS Z Forder Qualitatssich Med Lab 6:Doc03Google Scholar
  2. 2.
    Burnett RW, et al. (1995) International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Approved IFCC recommendations on whole blood sampling, transport and storage for simultaneous determination of pH, blood gases and electrolytes. Eur J Clin Chem Clin Biochem 33(4): 247–253Google Scholar
  3. 3.
    Carraro P, Plebani M (2007) Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 53(7): 1338–1342CrossRefPubMedGoogle Scholar
  4. 4.
    CLSI document H3-A6. Edition, A.S.S., Wayne, PA: Clinical and Laboratory Standards Institute, 2007Google Scholar
  5. 5.
    Davis MD, et al. (2013) AARC Clinical Practice Guideline: Blood Gas Analysis and Hemoximetry: 2013. Respiratory Care 58(10): 1694–1703CrossRefPubMedGoogle Scholar
  6. 6.
    Ehrmeyer SS, Laessig RH (2007) Point-of-care testing, medical error, and patient safety: a 2007 assessment. Clin Chem Lab Med 45(6): 766–773Google Scholar
  7. 7.
    Gruszecki AC, et al. (2003) Utilization, reliability, and clinical impact of point-of-care testing during critical care transport: six years of experience. Clin Chem 49(6 Pt 1): 1017–1019CrossRefPubMedGoogle Scholar
  8. 8.
    Gurr E, et al. (2011) Musterstandardarbeitsanweisung Präanalytik/Exemplary standard operation procedure pre-examination/Arbeitsgruppe Richtwerte der Deutschen Vereinten Gesellschaft für Klinische Chemie und Laboratoriumsmedizin. LaboratoriumsMedizin 35:55–60CrossRefGoogle Scholar
  9. 9.
    Laposata M, Dighe A (2007) “Pre-pre” and “post-post” analytical error: high-incidence patient safety hazards involving the clinical laboratory. Clin Chem Lab Med 45(6): 712–719Google Scholar
  10. 10.
    Lippi G, et al. (2006) Phlebotomy issues and quality improvement in results of laboratory testing. Clin Lab 52:217–230Google Scholar
  11. 11.
    Lippi G, et al. (2006) Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 44: 358–365Google Scholar
  12. 12.
    Meier, F.A. and B.A. Jones (2005) Point-of-care testing error: sources and amplifiers, taxonomy, prevention strategies, and detection monitors. Arch Pathol Lab Med 129(10): 1262–1267Google Scholar
  13. 13.
    Nichols JH (2005) Medical Errors: Can We Achieve An Error-Free System? Point of Care 4(4): 139–141Google Scholar
  14. 14.
    O’Kane MJ, et al. (2011) Quality Error Rates in Point-of-Care Testing. Clinical Chemistry 57(9): 1267–1271CrossRefPubMedGoogle Scholar
  15. 15.
    Panpradist N, et al. (2014) Swab Sample Transfer for Point-Of-Care Diagnostics: Characterization of Swab Types and Manual Agitation Methods. PLoS ONE 9(9): e105786CrossRefPubMedPubMedCentralGoogle Scholar
  16. 16.
    Plebani M, Carraro P (1997) Mistakes in a stat laboratory: types and frequency. Clin Chem 43(8 Pt 1): 1348–1351Google Scholar
  17. 17.
    Plebani M (2007) Errors in laboratory medicine and patient safety: the road ahead. Clin Chem Lab Med 45(6): 700–707Google Scholar
  18. 18.
    Schifman RB, Howanitz PJ, Souers RJ (2016) Point-of-Care Glucose Critical Values: A Q-Probes Study Involving 50 Health Care Facilities and 2349 Critical Results. Archives of Pathology & Laboratory Medicine 140(2): 119–124CrossRefGoogle Scholar
  19. 19.
    Senn L, et al. (2012) Which anatomical sites should be sampled for screening of methicillin-resistant Staphylococcus aureus carriage by culture or by rapid PCR test? Clinical Microbiology and Infection 18(2): E31-E33CrossRefPubMedGoogle Scholar
  20. 20.
    Stahl M, Lund ED, Brandslund I (1998) Reasons for a laboratory’s inability to report results for requested analytical tests. Clin Chem 44(10): 2195–2197Google Scholar
  21. 21.
    Thompson ND, Schaefer MK (2011) “Never events”: hepatitis B outbreaks and patient notifications resulting from unsafe practices during assisted monitoring of blood glucose, 2009–2010. J Diabetes Sci Technol 5(6):1396–1402CrossRefPubMedPubMedCentralGoogle Scholar

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Andreas Bietenbeck
    • 1
  1. 1.Klinikum rechts der TU MünchenInstitut für Klinische Chemie und PathobiochemieMünchenGermany

Personalised recommendations