Real-time Sitting Posture Monitoring System for Functional Scoliosis Patients

  • Ji-Yong Jung
  • Soo-Kyung Bok
  • Bong-Ok Kim
  • Yonggwan Won
  • Jung-Ja Kim
Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 339)

Abstract

In recent years, with the increase in sitting time, real-time posture monitoring system is needed. We developed sitting posture monitoring system with accelerometer to evaluate postural balance. Unstable structure of the system was designed to assess asymmetrical balance caused by habitual sitting position. Postural patterns of normal group and patients with functional scoliosis group were analyzed. Consequently, inclination angle of scoliosis group were tilted to the posterior and left side. From these results, we concluded that real-time sitting posture monitoring system can be utilized to measure asymmetrical balance of patients and provide accurate diagnosis as well as treatment for individuals.

Keywords

Real-time monitoring system Functional scoliosis Postural balance Sitting 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Gopalai, A.A., Senanayake, S.M., Kiong, L.C., Gouwanda, D.: Real-time Stability Measurement System for Postural Control. J. Bodyw. Mov. Ther. 15, 453-464 (2011)Google Scholar
  2. 2.
    Bechly, K.E., Carender, W.J., Myles, J.D., Sienko, K.H.: Determining the preferred modality for real-time biofeedback during balance training. Gait Posture. 37, 391–396 (2013)Google Scholar
  3. 3.
    Mukhopadhyay, S.C., Ihara, I.: Sensors and Technologies for Structural Health Monitoring: A Review. In: Mukhopadhyay. S.C. (eds.) New Development in Sensing Technology for Structural Health Monitoring 2011. LNEE, vol. 96, pp. 1-14. Springer, Heidelberg (2011)Google Scholar
  4. 4.
    Gupta, P., Dallas, T.: Feature Selection and Activity Recognition System using a Single Triaxial Accelerometer. IEEE Trans. Biomed. Eng. 61, 1780-1786 (2014)Google Scholar
  5. 5.
    Karantonis, D.M., Narayanan, M.R.: Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. IEEE Trans. Int. Tech. Biomed. 10, 156-167 (2006)Google Scholar
  6. 6.
    Curone, D., Bertolotti, G.M., Cristiani, A., Secco, E.L., Magenes, G.: A real-time and self-calibrating algorithm based on triaxial accelerometer signals for the detection of human posture and activity. IEEE Trans. Inf. Tech. Biomed. 14, 1098-1105 (2010)Google Scholar
  7. 7.
    Bliley, K.E., Schwab, D.J., Holmes, D.R., Kane, P.H., Levine, J.A., Daniel, E.S., Gilbert, B.K.: Design of a compact system using a MEMS accelerometer to measure body posture and ambulation. In: 19th IEEE International Symposium on Computer-Based Medical Systems, pp. 335-340. IEEE Press, Utah (2006)Google Scholar
  8. 8.
    Wang, Z.W., Wang, W.J., Sun, M.H., Liu, Z., Zhu, Z.Z., Zhu, F., Qiu, X.S., Qian, B.P., Wang, S.F., Qiu, Y.: Characteristics of the pelvic axial rotation in adolescent idiopathic scoliosis: a comparison between major thoracic curve and major thoracolumbar/lumbar curve. Spine J. 14, 1873-1878 (2014)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2015

Authors and Affiliations

  • Ji-Yong Jung
    • 1
  • Soo-Kyung Bok
    • 2
  • Bong-Ok Kim
    • 2
  • Yonggwan Won
    • 3
  • Jung-Ja Kim
    • 4
    • 5
  1. 1.Department of Healthcare EngineeringChonbuk National University, College of EngineeringJeonjuRepublic of Korea
  2. 2.Department of Rehabilitation MedicineChungnam National University HospitalDaejeonRepublic of Korea
  3. 3.Department of Electronics and Computer EngineeringCollege of Engineering, Chonnam National UniversityGwangjuSouth Korea
  4. 4.Division of Biomedical EngineeringCollege of Engineering, Chonbuk National UniversityJeonjuRepublic of Korea
  5. 5.Research Center of Healthcare & Welfare Instrument for the AgedChonbuk National UniversityJeonjuRepublic of Korea

Personalised recommendations