Chemistry of Marine Water and Sediments pp 403-413 | Cite as
Luminescence for the Analysis of Organic Compounds in Natural Waters
Abstract
Many widely used synthetic chemicals, as well as industrial by-products, are continuously emitted into the environment. Even if present in low quantities, some of these substances or their degradation products represent a threat for the health of humans and wildlife. Sometimes they accumulate in living organisms and target organs (bioaccumulation) so that their concentrations increase along the food chain. Natural waters (rivers, lakes, seas, and ground waters) are among the most endangered environments, since in many cases these substances are directly released in them. Moreover, natural waters represent an important way by which pollutants travel along long distances. Molecules with low water solubility, i.e. with high lipophilicity (pesticides, aromatic hydrocarbons and their derivatives, surfactants, oestrogen-like compounds, etc.) could be present in the particulate matter of fresh and marine water. The analysis of organic compounds in natural waters is therefore of crucial importance in the monitoring of pollution and in risk assessing for humans and environment. This requires rapid and sensitive analytical procedures for the detection of organic pollutants that should be suitable for performing screening analysis of a large number of samples.
Keywords
Anal Chim Phthalate Ester Yeast Oestrogen Screen Oestrogenic Activity Sensitive Analytical ProcedurePreview
Unable to display preview. Download preview PDF.
References
- Balaguer P, François F, Comunale F, Fenet H, Boussioux AM, Pons M, Nicolas JC, Casellas C (1999) Reporter cell lines to study the estrogenic effects of xenoestrogens. Sci Tot Environ 233:47–56CrossRefGoogle Scholar
- Belkin S, Smulski DR, Danon S, Vollmer AC, Dyk TK van, LaRossa RA (1997) A panel of stress-responsive luminous bacteria for the detection of selected classes of toxicants. Wat Res 31:3009–3016CrossRefGoogle Scholar
- De Zwart D, Sloof W (1981) The Microtox as an alternative assay in the acute toxicity assessment of water pollutants. Aquat Toxicol 4:129–138CrossRefGoogle Scholar
- Dzgoev A, Mecklenburg M, Xie B, Miyabayashi A, Larsson PO, Danielsson B (1997) Optimization of a charge coupled device imaging enzyme linked immuno sorbent assay and supports for the simultaneous determination of multiple 2,4-D samples. Anal Chim Acta 347:87–93CrossRefGoogle Scholar
- Emon JM Van(1987) Interim report on development and demonstration of immunoassay detection systems for rapid screening at superfund sites. EPA/600/X-87/414Google Scholar
- Emon JM Van, Gerlach CL (1995) A status report on field-portable immunoassays. Environ Sci Technol 29:312A-317ACrossRefGoogle Scholar
- Emon JM Van, Lopez-Avila V (1992) Immunochemical methods for environmental analysis. Anal Chem 64:79A-88ACrossRefGoogle Scholar
- Heitzer A, Malachowsky K, Thonnard JE, Bienkowski PR, Sayler GS (1994) Optical sensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium. Appl Environ Microbiol 60:1487–1494Google Scholar
- Ius A, Bacigalupo MA, Roda A, Vaccari C (1992) Development of a time-resolved fluorimmunoassay of benzo(a)pyrene in water. Fres J Anal Chem 343:55–56CrossRefGoogle Scholar
- Ius A, Bacigalupo MA, Meroni G, Pistillo A, Roda A (1993) Development of a time-resolved fluoroimmunoassay for phthalate esters in water. Fres J Anal Chem 345:589–591CrossRefGoogle Scholar
- Kameth MF, Aherne GW, Stevenson D (1996) Development and evaluation of a chemiluminescent immunoassay for chlortoluron using a camera luminometer. Analyst 121:329–332CrossRefGoogle Scholar
- King JMH, DiGrazia PM, Applegate B, Burlage R, Sanseverino J, Dunbar P, Larimer F, Sayler GS (1990) Rapid, sensitive bioluminescent reporter technology for naphthalene exposure and biodegradation. Science 249:778–781CrossRefGoogle Scholar
- Köhler S, Belkin S, Schmid RD (2000) Reporter gene bioassays in environmental analysis. Fres J Anal Chem 366:769–779CrossRefGoogle Scholar
- Legler J, Brink CE van den, Brouwer A, Murk AJ, Saag PT van der, Vethaak AD, Burg B van der (1999) Development of a stably transfected estrogen receptor-mediated luciferase reporter gene assay in the human T47D breast cancer line. Toxicol Sci 48:55–66CrossRefGoogle Scholar
- Lewis JC, Daunert S(2000) Photoproteins as luminescent labels in binding assays. Fres J Anal Chem 366:760–768CrossRefGoogle Scholar
- Marquette CA, Blum LJ (1998) Electrochemiluminescence of luminol for 2,4-D optical immunosensing in a flow injection analysis system. Sensor Actuat B 51:100–106CrossRefGoogle Scholar
- Murk AJ, Legler J, Denison MS, Giesy JP, Guchte C van der, Brouwer A(1996) Chemical-activated luciferase gene expression (CALUX): A novel in vitro bioassay for Ah receptor active compounds in sediments and pore water. Fund Appl Toxicol 33:149–160CrossRefGoogle Scholar
- Pasini P, Gentilomi G, Guardigli M, Baraldini M, Musiani M, Roda A (2001) A chemiluminescent whole cell biosensor for assessing estrogenic activity. In: Case JF, Herring PJ, Robison BH, Haddock SHD, Kricka LJ, Stanley PE (eds) Bioluminescence and chemiluminescence 2000. World Scientific Publishing Company, Singapore, pp 327–330Google Scholar
- Pons M, Gagne D, Nicolas JC, Mehtali M (1990) A new cellular model of response to estrogens: A bioluminescent test to characterize (anti)estrogen molecules. Bio Techniques 9:450–459Google Scholar
- Rehmann K, Schramm K-W, Kettrup AA (1999) Applicability of a yeast oestrogen screen for the detection of oestrogen-like activities in environmental samples. Chemosphere 38:3303–3312CrossRefGoogle Scholar
- Roda A, Girotti S, Lodi S, Preti S (1984) Development of a sensitive immunoassay for plasma and salivary steroids. Talanta 31:895–900CrossRefGoogle Scholar
- Roda A, Girotti S, Lodi S, Preti S (1984) Development of a sensitive immunoassay for plasma and salivary steroids. Talanta 31:895–900CrossRefGoogle Scholar
- Roda A, Rauch P, Ferri E, Girotti S, Ghini S, Carrea G, Bovara R (1994) Chemiluminescent flow sensor for the determination of Paraoxon and Aldicarb pesticides. Anal Chim Acta 294:35–42CrossRefGoogle Scholar
- Routledge EJ, Sumpter JP (1996) Estrogenic activity of surfactants and some of their degradation products assessed using a recombinant yeast screen. Environ Toxicol Chem 15:241–248CrossRefGoogle Scholar
- Samsonova JV, Rubtsova MY, Kiseleva AV, Ezhov AA, Egorov AM (1999) Chemiluminescent multiassay of pesticides with horseradish peroxidase as a label. Biosens Bioelectron 14:273–281CrossRefGoogle Scholar
- Shetty RS, Ramanathan S, Badr IH, Wolford JL, Daunert S (1999) Green fluorescent protein in the design of a living biosensing system for L-arabinose. Anal Chem 71:763–768CrossRefGoogle Scholar
- Sticher P, Jaspers MCM, Stemmler K, Harms H, Zehneder AJB, Meer JR van der (1997) Development and characterization of a whole-cell bioluminescent sensor for bioavailable middle-chain alkanes in contaminated groundwater samples. Appl Environ Microbiol 63:4053–4060Google Scholar
- Verschaeve L, Gompel J Van, Thilemans L, Regniers L, Vanparys P, Lelie D van der (1999) VITOTOX bacterial genotoxicity and toxicity test for the rapid screening of chemicals. Environ Mol Mutagen 33:240–248CrossRefGoogle Scholar
- Weller MG, Schuetz AJ, Winklmair M, Niessner R (1999) Highly parallel affinity sensor for the detection of environmental contaminants in water. Anal Chim Acta 393:29–41CrossRefGoogle Scholar
- Wilson R, Barker MH, Schiffrin DJ, Abuknesha R (1997) Electrochemiluminescence flow injection immunoassay for atrazine. Biosens Bioelectron 12:277–286CrossRefGoogle Scholar