Advertisement

Effect of Display Size on Body Sway in Seated Posture While Viewing an Hour-Long Stereoscopic Film

  • Kazuki Yoshikawa
  • Hiroki Takada
  • Masaru Miyao
Part of the Lecture Notes in Computer Science book series (LNCS, volume 8010)

Abstract

Viewing stereoscopic films may have adverse effects, such as asthenopia and visually induced motion sickness (VIMS). The phenomenon of VIMS is not fully understood, so the aim of this study is to evaluate the effect of viewing a long stereoscopic film on the human body. We conducted stabilometric analysis on subjects in the Romberg posture, carried out flicker tests, and provided subjective questionnaires to detect fatigue and eye strain every 20 min. Symptoms of VIMS were detected during exposure to an hour-long stereoscopic film. The display size and the engagement were analyzed for their affect on the total locus length and the sway area, respectively. The severity of the motion sickness induced by viewing the 3D film was measured by stabilometry, and the analogous sway was not observed in participants after viewing the 2D film in this study. Based on these results, guidelines can be developed to ensure safety while viewing stereoscopic movies.

Keywords

Visually induced motion sickness Stabilometry Liquid crystal displays (LCDs) Hour-long stereoscopic film 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Okawa, T., Tokita, T., Shibata, Y., Ogawa, T., Miyata, H.: Equilibrium Research 55(3), 283–293 (1995)CrossRefGoogle Scholar
  2. 2.
    Kaga, K.: Structure of Vertigo, Japan, Tokyo, pp. 23–26 (1992)Google Scholar
  3. 3.
    Okawa, T., Tokita, T., Shibata, Y., Ogawa, T., Miyata, H.: Equilibrium Research 54(3), 296–306 (1996)CrossRefGoogle Scholar
  4. 4.
    Takada, H., Fujikake, K., Miyao, M., Matsuura, Y.: Proc. VIMS 2007, pp. 178–183 (2007)Google Scholar
  5. 5.
    Hatada, T.: Nikkei Electronics 444, 205–223 (1988)Google Scholar
  6. 6.
    Kakeya, H.: Proc. SPIE, vol. 6490, p. 64900J (2007)Google Scholar
  7. 7.
    Kennedy, R.S., Lane, N.E., Berbaum, K.S., Lilienthal, M.G.: International Journal of Aviation Psychology 3, 203–220 (1993)CrossRefGoogle Scholar
  8. 8.
    Yokota, Y., Aoki, M., Mizuta, K.: Acta Otolaryngologia 125, 280–285 (2005)CrossRefGoogle Scholar
  9. 9.
    Takada, H., Kitaoka, Y., Ichikawa, M., Miyao, M.: Equilibrium Res. 62, 168–180 (2003)CrossRefGoogle Scholar
  10. 10.
    Goldie, P.A., Bach, T.M., Evans, O.M.: Arch. Phys. Med. Rehabil. 70, 510–517 (1986)Google Scholar
  11. 11.
    Collins, J.J., De Luca, C.J.: Exp. Brain Res. 95, 308–318 (1993)CrossRefGoogle Scholar
  12. 12.
    Newell, K.M., Slobounov, S.M., Slobounova, E.S., Molenaar, P.C.: Exp. Brain Res. 113, 158–164 (1997)CrossRefGoogle Scholar
  13. 13.
    Takada, H., Kitaoka, Y., Shimizu, Y.: Forma 16, 17–46 (2001)zbMATHGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2013

Authors and Affiliations

  • Kazuki Yoshikawa
    • 1
  • Hiroki Takada
    • 1
  • Masaru Miyao
    • 2
  1. 1.Department of Human and Artificial Intelligent Systems, Graduate School of EngineeringUniversity of FukuiFukuiJapan
  2. 2.Graduate School of Information ScienceNagoyaJapan

Personalised recommendations