Radiation-Free Drill Guidance in Interlocking of Intramedullary Nails

  • Benoit Diotte
  • Pascal Fallavollita
  • Lejing Wang
  • Simon Weidert
  • Peter-Helmut Thaller
  • Ekkehard Euler
  • Nassir Navab
Part of the Lecture Notes in Computer Science book series (LNCS, volume 7510)

Abstract

Intramedullary nailing is a technically demanding procedure which involves an excessive amount of X-ray acquisitions; one study lists as many as 48 to successfully complete the procedure. In this work, a novel low cost radiation-free drilling guide is designed to assist surgeons in completing the distal locking procedure without any X-ray acquisitions. Using an augmented reality fluoroscope that coregisters optical and X-ray images, we exploit solely the optical images to detect the drilling guide in order to estimate the tip position in real-time in X-ray. We tested over 200 random drill guide poses showing a mean tip-estimation error of 1.72 ± 0.7 mm which is significantly robust and accurate for the interlocking. In a preclinical study on dry bone phantom, three expert surgeons successfully completed the interlocking 56 out of 60 trials with no X-ray acquisition for guidance and an average time of 2 min.

Keywords

Augmented Reality Intramedullary Nail Expert Surgeon Humeral Shaft Fracture Drill Guide 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Leloup, T., El Kazzi, W., Schuind, F., Warzee, N.: A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation. IEEE Transactions on Medical Imaging 27(9), 1202–1212 (2008)CrossRefGoogle Scholar
  2. 2.
    Müller, L.P., Suffner, J., Wenda, K., Mohr, W., Rommens, P.M.: Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29(6), 461–468 (1998)CrossRefGoogle Scholar
  3. 3.
    Navab, N., Heining, S.M., Traub, J.: Camera augmented mobile c-arm (camc): Calibration, accuracy study and clinical applications. IEEE Transactions on Medical Imaging 29(7), 1412–1423 (2009)CrossRefGoogle Scholar
  4. 4.
    Rohilla, R., Singh, R., Magu, N., Devgan, A., Siwach, R., Sangwan, S.: Simultaneous use of cannulated reamer and schanz screw for closed intramedullary femoral nailing. ISRN Surg. (2011) (published online)Google Scholar
  5. 5.
    Suhm, N., Messmer, P., Zuna, I., Jacob, L.A., Regazzoni, P.: Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. a prospective, controlled clinical study. Injury 35(6), 567–574 (2004)CrossRefGoogle Scholar
  6. 6.
    Wang, L., Landes, J., Weidert, S., Blum, T., von der Heide, A., Euler, E., Navab, N.: First Animal Cadaver Study for Interlocking of Intramedullary Nails under Camera Augmented Mobile C-arm. In: Navab, N., Jannin, P. (eds.) IPCAI 2010. LNCS, vol. 6135, pp. 56–66. Springer, Heidelberg (2010)CrossRefGoogle Scholar
  7. 7.
    Whatling, G., Nokes, L.: Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 37(2), 109–119 (2006)CrossRefGoogle Scholar
  8. 8.
    Yaniv, Z., Joskowicz, L., Member, S.: Precise robot-assisted guide positioning for distal locking of intramedullary nails. IEEE Transactions on Medical Imaging 24(5), 624–635 (2005)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2012

Authors and Affiliations

  • Benoit Diotte
    • 1
  • Pascal Fallavollita
    • 1
  • Lejing Wang
    • 1
  • Simon Weidert
    • 2
  • Peter-Helmut Thaller
    • 2
  • Ekkehard Euler
    • 2
  • Nassir Navab
    • 1
  1. 1.Computer Aided Medical Procedures (CAMP)TU MunichGermany
  2. 2.Trauma Surgery Department, Klinikum InnenstadtLMU MunichGermany

Personalised recommendations