The Design of Partial Electric and Control System for 500kV Substation

  • Haimei Xiao
  • Lichun Shi
Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 140)

Abstract

The good design of the electric section in substation and its stable move may effect the electrical system of substation directly, this paper aim at the design of an electric primary section in substation and its supervisory system for the 500kv substation. based on the principle of connecting line of the electric primary section in substation and the function of the realization, and then by comparing the design of the double bus bars of double with bypass line subsection and line of 3/2 circuit breaker. we fixed the main wiring scheme. The design based on Programmable Logic Controller and supervisory control and data acquisition is an electric primary section of monitoring system.and the monitoring and control of the state and parameter in electric primary section in substation are realized by the monitoring system, which ensure the security of system, improve the level of automation and intelligent.

Keywords

Substation electric primary section supervisory control system PLC 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Wang, M.-X., Zhang, Q.: Analysis on Influence of Ground Electrode Current in HVDC on Ac Power Network. Power System Technology 03 (2005)Google Scholar
  2. 2.
    Yuan, Q.-Y.: Present State and Application Prospect of Ultra HVDC Transmission in China. Power System Technology 14 (2005)Google Scholar
  3. 3.
    Su, H.-T., Qi, X., Wu, Y.: Study on Market Demand of UHVDC Power Transmission in China. Power System Technology 24 (2005)Google Scholar
  4. 4.
    Wu, G.-F., Lu, J.-Y., Shao, F.-Y.: Research on electromagnetic environment of the next voltage level of transmission system in China. Electric Power 06 (2005)Google Scholar
  5. 5.
    Shao, F.: Power Frequency Electromagnetic Introduction on DC Transmission Line Caused by a Parallel Proximate AC Transmission Line. Power System Technology 12 (1998)Google Scholar
  6. 6.
    Zhu, Y.-Y., Jiang, W.-P., Zeng, Z.-H., et al.: Studying on Measures of Restraining DC Current Through Transformer Neutrals. In: Proceedings of the CSEE, vol. 13 (2005)Google Scholar

Copyright information

© Springer Berlin Heidelberg 2012

Authors and Affiliations

  • Haimei Xiao
    • 1
  • Lichun Shi
    • 1
  1. 1.Henan PolytechnicZhengzhouChina

Personalised recommendations