Multi-frequency Microwave Radiometer System for Measuring Deep Brain Temperature in New Born Infants

  • Conference paper
5th Kuala Lumpur International Conference on Biomedical Engineering 2011

Part of the book series: IFMBE Proceedings ((IFMBE,volume 35))

Abstract

Hypothermic brain treatment for newborn babies are currently hindered by the lack of appropriate techniques for continuous and non-invasive measurement of deep brain temperature. Microwave radiometry (MWR) is one of the promising methods that is completely passive and inherently safe. Five-band microwave radiometer system and its feasibility were reported with a confidence interval level of the temperature estimation of about 1.6 °C at 5 cm depth from the surface. This result was not good enough for clinical application because clinical requirement is less than 1 °C for both accuracy and stability. This paper describes the improved result of temperature resolutions of the five radiometer receivers, and shows the new confidence interval obtained form temperature measurement experiment using an agar phantom based on a water-bath. Temperature resolutions were 0.103, 0.129, 0.138, 0.105 and 0.111 °C for 1.2, 1.65, 2.3, 3.0 and 3.6 GHz receiver, respectively, and new confidence interval was 0.51 °C at 5 cm from surface. We believe that the system takes a step closer to the clinical hypothermic treatment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Sugiura, T., Hirata, H., Hand, J.W., Mizushina, S. (2011). Multi-frequency Microwave Radiometer System for Measuring Deep Brain Temperature in New Born Infants. In: Osman, N.A.A., Abas, W.A.B.W., Wahab, A.K.A., Ting, HN. (eds) 5th Kuala Lumpur International Conference on Biomedical Engineering 2011. IFMBE Proceedings, vol 35. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21729-6_86

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-21729-6_86

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-21728-9

  • Online ISBN: 978-3-642-21729-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics