Contrast Medium Injection in MSCT: Present Status and Future Perspectives
Abstract
In the past years, we have assisted with several technical developments which have totally changed the performances of computed tomography (CT) equipment. Starting from the early 1970s, the scan time was several minutes, the reconstruction time was almost 1 min, the minimum slice thickness was more than 1 cm, the matrix was limited and the contrast resolution was poor. By the late 1990s and the year 2000, there were dramatic improvements in terms of speed of acquisition and reconstruction with a reduction in slice thickness to less than 1 mm and a significant increase in spatial resolution. These technical improvements also meant the possibility to perform new types of studies with CT previously not possible, such as high-resolution dynamic evaluation of parenchymal organs and lesions and non-invasive angiographies.
Keywords
Contrast Agent Compute Tomography Angiography Spiral Compute Tomography Iodine Concentration Arterial EnhancementPreview
Unable to display preview. Download preview PDF.
References
- 1.Passariello R (1985) Angio-CT techniques. Eur J Radiol 5:193–198PubMedGoogle Scholar
- 2.Passariello R et al. (1980) Automatic contrast medium injector for computer tomography. J Comput Assist Tomogr 4:278–279PubMedGoogle Scholar
- 3.Heiken JP et al. (1993) Dynamic contrast-enhanced CT of the liver: comparison of contrast medium injection rates and uniphasic and biphasic injection protocols. Radiology 187:327–331.PubMedGoogle Scholar
- 4.Fleishmann D et al. (1999) Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform. J Comput Assist Tomogr 23:474–484CrossRefGoogle Scholar
- 5.Blomey MJ et al. (1997) Bolus dynamics: theoretical and experimental aspects. Br J Radiol; 70:351–359Google Scholar
- Boos M et al. (2001) Arterial first pass Gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes. JMRGoogle Scholar
- 7.Mitsuzaki K et al. (1999) Optimal protocol for injection of contrast material at MR Angiography: study of healthy volunteers. Radiology 213:913–918PubMedGoogle Scholar
- 8.Awai K et al. (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effects of different concentrations of contrast material at multi-detector row helical CT. Radiology 224:757–763PubMedCrossRefGoogle Scholar
- 9.Brink J A et al. (1997) Depistion of pulmonary emboli with spiral CT: optimization of display window settings in a porcine model. 204:703–708Google Scholar
- 10.Yamashita Y et al. (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material-A prospective study. Radiology 216:718–723PubMedGoogle Scholar
- 11.Luboldt W et al. (1999) effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner. Invest Radiol 26:751–750CrossRefGoogle Scholar
- 12.Fleischmann D et al. (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT Angiography 214:363–371Google Scholar