Performance of the New Double Layer Amorphous Selenium Detector for Digital Mammography Compared to the FDA Approved CR System for Digital Mammography

  • Rafael Salvador
  • Rafael Salvador-Izquierdo
  • Leonardo Romero
  • Xavier Salvador-Izquierdo
  • Manuel Salvador
Part of the Lecture Notes in Computer Science book series (LNCS, volume 6136)

Abstract

The performance of a new double layer amorphous Selenium detector for digital mammography is compared to the FDA approved CR system for digital mammography in a two step study. A study comparing radiation between both systems is first done to obtain the best settings for a clinical study. In a second step the results in terms of quality are evaluated by three readers comparing the final images. A minimal reduction of dose (20%) is obtained and a better definition of glandular structures is demonstrated with the new device.

Keywords

Breast Breast Cancer Digital Mammography 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Thijssen, M.A.O., Bijkerk, K.R., Van der Burght, R.J.M.: Project Quality Assurance in Radiology. Manual CDRAD-phantom type 2.0. Artinis Medical Systems B.V. Andelst. The Netherlands (2003)Google Scholar
  2. 2.
    ACR Mammography Quality Control Manual, Reston, Va. American College of Radiology (1999)Google Scholar
  3. 3.
    Mahadevappa, M.: AAPM/RSNA Physics Tutorial for Residents, Digital mammography: An Overview. Radiographics 24, 1747–1760 (2004)CrossRefGoogle Scholar
  4. 4.
    Bick, U., Diekmann, F.: Digital mammography: what do we and what don’t we know? Eur. Radiol. 17, 1931–1942 (2007)CrossRefGoogle Scholar
  5. 5.
    Veip, Y.A., Mazurov, A.I.: Analysis of various technologies for digital X-ray image detector design. Biomedical Engineering 42(5), 261–264 (2008)CrossRefGoogle Scholar
  6. 6.
    Wolbarst, A.B., Hendee, W.R.: Evolving and experimental technologies in medical imaging. Radiology 236(1), 16–39 (2006)Google Scholar
  7. 7.
    Körner, M., Weber, C., Wirth, S., Pfeifer., K.-J., Reiser, M.F., Treitl, M.: Advances in Digital Radiography: Physical Principles and System Overview. Radiographics 27, 675–686 (2007)CrossRefGoogle Scholar
  8. 8.
    Reznik, N., Komljenovic, P.T., German, S., Rowlands, J.A.: Digital radiography using amorphous selenium: Photoconductively activated switch (PAS) readout system. Med. Phys. 35, 1039–1050 (2008)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2010

Authors and Affiliations

  • Rafael Salvador
    • 1
  • Rafael Salvador-Izquierdo
    • 1
  • Leonardo Romero
    • 1
  • Xavier Salvador-Izquierdo
    • 1
  • Manuel Salvador
    • 1
  1. 1.Department of Radiology, CDI ImagineHospital Universitari Vall d’HebrónBarcelonaSpain

Personalised recommendations