In this work we present a method to combine complex-valued phased array MR data based on a uniform sensitivity approach, which incorporates sensitivity profiles calculated from afore acquired data. The algorithm was implemented on a clinical 3T whole-body MR-Scanner and embedded into the vendor-specific standard reconstruction chain.

Additionally, it was linked with the GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) procedure to take advantage of partial parallel acquisition techniques as well. Thus, under-sampled data can be reconstructed with GRAPPA and subsequently combined with the presented method. Phase images reconstructed with the proposed method were in excellent agreement with reference data and did not suffer from errors due to incorrectly combined data.

Keywords

Phase images phased array MRI image reconstruction partial parallel acquisition techniques GRAPPA 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Rerferences

  1. 1.
    Jezzard P, Balaban RS (1995) Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 34(1):65–73CrossRefGoogle Scholar
  2. 2.
    Dumoulin CL (1995) Phase contrast MR angiography techniques. Magn Reson Imaging Clin N Am 3(3):399–411Google Scholar
  3. 3.
    Reichenbach JR, Venkatesan R et al. (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology 204(1):272–277Google Scholar
  4. 4.
    Reichenbach JR, Haacke EM (2001) High-resolution BOLD venographic imaging: a window into brain function. NMR Biomed 14(7–8):453–467CrossRefGoogle Scholar
  5. 5.
    Herrmann K-H, Rauscher A et al. (2006) Improved contrast in dynamic contrast enhanced MRI by combining complex in-phase and opposed-phase data: simulations and phantom experiment, Proc Intl Soc Mag Reson Med 14, Seattle, Washington, USA, 2006, p 1537Google Scholar
  6. 6.
    Noll DC, Nishimura DG et al. (1991) Homodyne Detection in Magnetic Resonance Imaging. IEEE Trans Med Imag 10(2):154–163CrossRefGoogle Scholar
  7. 7.
    Roemer PB, Edelstein WA et al. (1990) The NMR phased array. Magn Reson Med 16(2):192–225CrossRefGoogle Scholar
  8. 8.
    Griswold MA, Jakob PM et al. (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47(6):1202–1210CrossRefGoogle Scholar
  9. 9.
    Walsh DO, Gmitro AF et al. (2000) Adaptive reconstruction of phased array MR imagery. Magn Reson Med 43(5):682–690CrossRefGoogle Scholar
  10. 10.
    Kittler J, Illingworth J (1986) Minimum error thresholding. Pat Rec 19(1):41–47CrossRefGoogle Scholar
  11. 11.
    Pruessmann KP, Weiger M et al. (1999) SENSE: Sensitivity Encoding for Fast MRI. Magn Reson Med 42(5):952–962CrossRefGoogle Scholar
  12. 12.
    Ben-Israel A, Greville TNE (2003) Generalized Inverses-Theory and Applications. Springer, BerlinzbMATHGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2009

Authors and Affiliations

  • Christian Ros
    • 1
    Email author
  • S. Witoszynskyj
    • 2
  • K. -H. Herrmann
    • 1
  • J. R. Reichenbach
    • 1
  1. 1.Medical Physics Group, Institute for Diagnostic and Interventional RadiologyFriedrich Schiller UniversityJenaGermany
  2. 2.Department of Diagnostic RadiologyMedical University of Vienna, AKHViennaAustria

Personalised recommendations