Validation of Finite Element Analysis for a New External Finger Fixator to Correct Flexion Deformity — A Preliminary Result

  • Herman Shah Abd Rahman
  • N. A. Abu Osman
  • W. A. B. Wan Abas
  • T. S. Tunku Ahmad
  • E. S. Ng
Part of the IFMBE Proceedings book series (IFMBE, volume 21)

Abstract

The purpose of this study is to validate of a new external finger fixator components by using finite element analysis (FEA). The new external finger fixator consists of proximal, middle and distal phalanges support sections and means for rigidly connecting each support to a hinge and its corresponding attached to phalanx through the movements of flexion or extension. The results from the analysis found that the entire components of the fixator conform to the performance based on the requirements for general duty (500 N load applied on uniformly distributed load). This analysis shows that the new external fixator is able to restore full function and dynamic range of motion for patients with flexion deformity at the finger joints without failure.

Keywords

External finger fixator Finite element analysis flexion deformity phalangeal bone 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

VI. References

  1. 1.
    Maxian TA, Brown TD, Pedersen DR, Callaghan JJ (1996). A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. Journal of Biomechanics 29(5) 687–692.CrossRefGoogle Scholar
  2. 2.
    Scifert CF, Brown TD, Lipman JD (1999). Finite element analysis of a novel design approach to resisting total hip dislocation. Clinical Biomechanics. 14(10):697–703.CrossRefGoogle Scholar
  3. 3.
    Namba RS, Keyak JH, Kim AS, Vu LP, Skinner HB (1998) Cementless implant composition and femoral stress. A finite element analysis. Clinical Orthopaedics & Related Research 347:261–267.Google Scholar
  4. 4.
    Vander Sloten J, Hobatho MC, Verdonck P (1998). Applications of computer modelling for the design of orthopaedic, dental and cardiovascular biomaterials. Proc Inst Mech Eng 212(6):489–500.Google Scholar
  5. 5.
    Prendergast PJ (1997). Finite element models in tissue mechanics and orthopaedic implant design. Clinical Biomechanics 12(6) 343–366.CrossRefGoogle Scholar
  6. 6.
    Siow Y.S, Ahmad T.S. and Goh S.Y (1999): Use of a New External Fixator for the Correction of Fixed Flexion Deformity of the Fingers. World Scientific Publishing Company. Hand Surgery 4(2): 167–174.CrossRefGoogle Scholar
  7. 7.
    Verdonschot N, Fennis WMM, Kuijs RH, Stolk J, Kreulen CM, Creugers NHJ (2001). Generation of 3D finite element models of restored human teeth using micro-CT techniques. Int J Prosthodont 14:310–315.Google Scholar
  8. 8.
    Smith, E.M., Juvinall, R.C., Bender, L.F., and Pearson, J.R (1964) “Role of the finger flexors in rheumatoid deformities of the metacarpophalangeal joints.” Arthritis and rheumatism 7:467–480.CrossRefGoogle Scholar
  9. 9.
    Chao, E.Y., Opgrande, J.D. and Axmear, F.E., (1976). “Three Dimensional Force Analysis of Finger Joints in Selected Isometric Hand Functions,” J. Biomechanics, 9: 387–396CrossRefGoogle Scholar
  10. 10.
    An, k. N., Cooney, W. P., Chao, E. Y. and Linsched, R. L. (1978) Functional strength assessment of normal fingers. In Advances in bioengineering. ASME, New York, 89–90.Google Scholar
  11. 11.
    Kong, Y.K. (2001), Optimum Design of Handle Shape through Biomechanical Modeling of Hand Tendon Forces, Ph.D. dissertation, University Park, PA: Pennsylvania State UniversityGoogle Scholar
  12. 12.
    J.W. Lee and K. Rim, (1990) A New Method for Measurement of Finger-phalangeal Force Experimental Mechanics 30(4): 392–397Google Scholar
  13. 13.
    S. Radhakrishnan and M. Nagaravindra (1993) Analysis of hand forces on health and diseases during maximum isometric grasping of cylinder. Medical & Biological Engineering & Computing: 372–376Google Scholar
  14. 14.
    Huiskes R, Chao Eys (1983). A survey of finite element analysis in orthopedic biomechanics: the first decade. J. Biomech 16:385–409CrossRefGoogle Scholar
  15. 15.
    Brekelmans, W.A.M., Poort, H.W. and Sloof, T.J.H. (1972), “A new method to analyse the mechanical behaviour of skeletal parts”, Acta Orthop Scand, 43: 301–317.CrossRefGoogle Scholar
  16. 16.
    Mackerle, J. (1992), “Finite and boundary element methods in biomechanics: a bibliography.(1976–1991)”, Eng Comput, 9, pp. 403–435.CrossRefMathSciNetGoogle Scholar
  17. 17.
    Prendergast, P.J. (1997), “Finite element models in tissue mechanics and orthopaedic implant design”, Clinical Biomechanics, 6, pp. 343–366CrossRefGoogle Scholar
  18. 18.
    H.S. Abd Rahman, N.A. Abu Osman, S. Yahud, T.S. Tunku Yahya and Ng Eng Seng (2007) A Study Of The External Finger Fixator To Correct Flexion Deformity Journal of Biomechanics, Volume 40,Supplement 2, Page S183CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2008

Authors and Affiliations

  • Herman Shah Abd Rahman
    • 1
  • N. A. Abu Osman
    • 1
  • W. A. B. Wan Abas
    • 1
  • T. S. Tunku Ahmad
    • 2
  • E. S. Ng
    • 2
  1. 1.Department of Biomedical Engineering, Faculty of EngineeringUniversity of MalayaKuala LumpurMalaysia
  2. 2.Department of Orthopaedic SurgeryFaculty of MedicineKuala LumpurMalaysia

Personalised recommendations