Single-Shot Pulse Sequences

  • Olaf Dietrich
Part of the Medical Radiology book series (MEDRAD)

Keywords

Parallel Imaging Spin Echo Haste Sequence Minimal Effective Distortion Artefact 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barth M, Metzler A, Klarhofer M, Roll S, Moser E, Leibfritz D (1999) Functional MRI of the human motor cortex using single-shot, multiple gradient-echo spiral imaging. Magn Reson Imaging 17:1239–1343PubMedCrossRefGoogle Scholar
  2. Block KT, Frahm J (2005) Spiral imaging: a critical appraisal. J Magn Reson Imaging 21:657–668PubMedCrossRefGoogle Scholar
  3. Haase A, Matthaei D, Bartkowski R, Duhmke E, Leibfritz D (1989) Inversion recovery snapshot FLASH MR imaging. J Comput Assist Tomogr 13:1036–1040PubMedCrossRefGoogle Scholar
  4. Heidemann RM, Griswold MA, Kiefer B, Nittka M, Wang J, Jellus V, Jakob PM (2003) Resolution enhancement in lung 1H imaging using parallel imaging methods. Magn Reson Med 49:391–394PubMedCrossRefGoogle Scholar
  5. Hennig J, Nauerth A, Friedburg H (1986) RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 3:823–833PubMedGoogle Scholar
  6. Mansfield P (1977) Multi-planar image formation using NMR spin echoes. J Phys C: Solid State Phys 10:L55–L58CrossRefGoogle Scholar
  7. Mansfield P, Coxon R, Hykin J (1995) Echo-volumar imaging (EVI) of the brain at 3.0 T: first normal volunteer and functional imaging results. J Comput Assist Tomogr 19:847–852PubMedCrossRefGoogle Scholar
  8. Schmidt CF, Degonda N, Luechinger R, Henke K, Boesiger P (2005) Sensitivity-encoded (SENSE) echo planar fMRI at 3T in the medial temporal lobe. Neuroimage 25:625–641PubMedCrossRefGoogle Scholar
  9. Song AW, Wong EC, Hyde JS (1994) Echo-volume imaging. Magn Reson Med 32:668–671PubMedGoogle Scholar
  10. Weiger M, Pruessmann KP, Osterbauer R, Bornert P, Boesiger P, Jezzard P (2002) Sensitivity-encoded single-shot spiral imaging for reduced susceptibility artefacts in BOLD fMRI. Magn Reson Med 48:860–866PubMedCrossRefGoogle Scholar
  11. Wielopolski PA, Schmitt F, Stehling MK (1998) Echo-planar imaging pulse sequences. In: Schmitt F, Stehling MK, Turner R (eds) Echo-planar imaging. Theory, technique and application. Springer, Berlin Heidelberg New York, pp 65–139Google Scholar
  12. Yang QX, Wang J, Smith MB, Meadowcroft M, Sun X, Eslinger PJ, Golay X (2004) Reduction of magnetic field inhomogeneity artefacts in echo planar imaging with SENSE and GESEPI at high field. Magn Reson Med 52:1418–1423PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2007

Authors and Affiliations

  • Olaf Dietrich
    • 1
  1. 1.Department of Clinical Radiology, University Hospitals — GrosshadernLudwig Maximilian University of MunichMunichGermany

Personalised recommendations