Abstract

Magnetic resonance imaging (MRI) has the substantial advantage over other imaging modalities that an excellent soft-tissue contrast for assessment of morphology can be combined with evaluation of function and metabolism. Due to the lack of exposure to radiation or iodinated contrast agents, imaging can be multiply repeated and extended to the entire body within a single MR scan. Thus, it is not surprising that whole-body MRI has been discussed since the early beginnings of clinical MRI, and is mentioned, e.g. in articles by Lauterbur (1980), Mansfield et al. (1980), and Edelstein et al. (1980).

Keywords

Positron Emission Tomography Standardize Uptake Value Technical Prerequisite Parallel Imaging Digital Mammography 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bammer R, Schoenberg SO (2004) Current concepts and advances in clinical parallel magnetic resonance imaging. Top Magn Reson Imaging 15:129–158CrossRefPubMedGoogle Scholar
  2. Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME (2001) Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 220:252–256PubMedGoogle Scholar
  3. Blaimer M, Breuer F, Mueller M, Heidemann RM, Griswold MA, Jakob PM (2004) SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method. Top Magn Reson Imaging 15:223–236CrossRefPubMedGoogle Scholar
  4. Dietrich O, Hajnal JV (1999) Extending the coverage of true volume scans by continuous movement of the subject. Proc Intl Soc Mag Reson Med 7:1653Google Scholar
  5. Dietrich O, Nikolaou K, Wintersperger BJ, Flatz W, Nittka M, Petsch R, Kiefer B, Schoenberg SO (2002) iPAT: applications for fast and cardiovascular MR imaging. Electromedica 70:133–146Google Scholar
  6. Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26: 375–385CrossRefPubMedGoogle Scholar
  7. Edelstein WA, Hutchison JM, Johnson G, Redpath T (1980) Spin warp NMR imaging and applications to human whole-body imaging. Phys Med Biol 25:751–756CrossRefPubMedGoogle Scholar
  8. Fenchel M, Requardt M, Tomaschko K, Kramer U, Stauder NI, Naegele T, Schlemmer HP, Claussen CD, Miller S (2005) Whole-body MR angiography using a novel 32-receivingchannel MR system with surface coil technology: first clinical experience. J Magn Reson Imaging 21:596–603CrossRefPubMedGoogle Scholar
  9. Ghanem N, Lohrmann C, Engelhardt M, Pache G, Uhl M, Saueressig U, Kotter E, Langer M (2006) Whole-body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological skeletal survey. Eur Radiol 16:1005–1014CrossRefPubMedGoogle Scholar
  10. Griswold MA (2007) Basic reconstruction algorithms. In: Schoenberg SO, Dietrich O, Reiser MF (eds) Parallel imaging in clinical MR applications. Springer, Berlin Heidelberg New York, pp 19–36CrossRefGoogle Scholar
  11. Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210CrossRefPubMedGoogle Scholar
  12. Heidemann RM, Ozsarlak O, Parizel PM, Michiels J, Kiefer B, Jellus V, Muller M, Breuer F, Blaimer M, Griswold MA, Jakob PM (2003) A brief review of parallel magnetic resonance imaging. Eur Radiol 13:2323–2337CrossRefPubMedGoogle Scholar
  13. Herborn CU, Goyen M, Quick HH, Bosk S, Massing S, Kroeger K, Stoesser D, Ruehm SG, Debatin JF (2004) Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease. AJR Am J Roentgenol 182:1427–1434PubMedGoogle Scholar
  14. Kramer H, Schoenberg SO, Nikolaou K, Huber A, Struwe A, Winnik E, Wintersperger BJ, Dietrich O, Kiefer B, Reiser MF (2005) Cardiovascular screening with parallel imaging techniques and a whole-body MR imager. Radiology 236:300–310CrossRefPubMedGoogle Scholar
  15. Kruger DG, Riederer SJ, Grimm RC, Rossman PJ (2002) Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 47:224–231CrossRefPubMedGoogle Scholar
  16. Lauterbur PC (1980) Progress in n.m.r. zeugmatography imaging. Philos Trans R Soc Lond B Biol Sci 289:483–487CrossRefPubMedGoogle Scholar
  17. Lichy MP, Wietek BM, Mugler JPIII, Horger W, Menzel MI, Anastasiadis A, Siegmann K, Niemeyer T, Konigsrainer A, Kiefer B, Schick F, Claussen CD, Schlemmer HP (2005) Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 40:754–760CrossRefPubMedGoogle Scholar
  18. Mansfield P, Morris PG, Ordidge RJ, Pykett IL, Bangert V, Coupland RE (1980) Human whole body imaging and detection of breast tumours by n.m.r. Philos Trans R Soc Lond B Biol Sci 289:503–510CrossRefPubMedGoogle Scholar
  19. Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962CrossRefPubMedGoogle Scholar
  20. Reeder SB (2007) Measurement of signal-to-noise ratio and parallel imaging. In: Schoenberg SO, Dietrich O, Reiser MF (eds) Parallel imaging in clinical MR applications. Springer, Berlin Heidelberg New York, pp 49–61CrossRefGoogle Scholar
  21. Ruehm SG, Goyen M, Quick HH, Schleputz M, Schleputz H, Bosk S, Barkhausen J, Ladd ME, Debatin JF (2000) Wholebody MRA on a rolling table platform (AngioSURF). Rofo 172:670–674PubMedGoogle Scholar
  22. Schlemmer HP, Schafer J, Pfannenberg C, Radny P, Korchidi S, Muller-Horvat C, Nagele T, Tomaschko K, Fenchel M, Claussen CD (2005) Fast whole-body assessment of metastatic disease using a novel magnetic resonance imaging system: initial experiences. Invest Radiol 40:64–71CrossRefPubMedGoogle Scholar
  23. Schmidt GP, Baur-Melnyk A, Tiling R, Hahn K, Reiser MF, Schoenberg SO (2004) Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system. Radiologe 44:889–898PubMedGoogle Scholar
  24. Schmidt GP, Baur-Melnyk A, Herzog P, Schmid R, Tiling R, Schmidt M, Reiser MF, Schoenberg SO (2005) High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography: experience on a 32-channel system. Invest Radiol 40:743–753CrossRefPubMedGoogle Scholar
  25. Schoenberg SO, Dietrich O, Reiser MF (eds) (2007) Parallel imaging in clinical MR applications. Springer, Berlin Heidelberg New YorkGoogle Scholar
  26. Sodickson DK, Manning WJ (1997) Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 38:591–603CrossRefPubMedGoogle Scholar
  27. Takahara T, Imai Y, Yamashita T, Yasuda S, Nasu S, Van Cauteren M (2004) Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med 22:275–282PubMedGoogle Scholar
  28. Zenge MO, Ladd ME, Vogt FM, Brauck K, Barkhausen J, Quick HH (2005) Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback. Magn Reson Med 54:707–711CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2008

Authors and Affiliations

  • Olaf Dietrich
    • 1
  • Stefan O. Schoenberg
    • 2
  1. 1.Department of Clinical Radiology, University Hospitals — GrosshadernLudwig-Maximilians-University of MunichMunichGermany
  2. 2.Department of Clinical Radiology, University Hospital Mannheim, Medical Faculty MannheimUniversity of HeidelbergMannheimGermany