Non-rigid Registration of 3D Ultrasound Images of Brain Tumours Acquired during Neurosurgery

  • Marloes M. J. Letteboer
  • Peter W. A. Willems
  • Max A. Viergever
  • Wiro J. Niessen
Part of the Lecture Notes in Computer Science book series (LNCS, volume 2879)

Abstract

Intraoperative brain deformation is one of the most contributing factors to the inaccuracy of image-guided neurosurgery systems. One option for correcting for this deformation is to acquire 3D ultrasound images during surgery and use these to update the information provided by the preoperatively acquired MR. To compare ultrasound volumes at different stages of surgery, non-rigid registration techniques are necessary. We present the results of applying a non-rigid registration algorithm, based on free-form deformations using B-splines and using normalized mutual information as a similarity measure, to 3D ultrasound volumes of two patients with brain tumours. For these two patients we registered an ultrasound volume acquired prior to opening the dura with an ultrasound volume acquired after opening the dura, but prior to surgery. When comparing the segmented tumours after affine registration plus free-form registration with a control point spacing of 4 mm to the segmented tumour volumes after registration with the image-guided surgery system, the volume overlap increased from approximately 76% to 96% for both patients.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Maurer, C.R., Hill, D.G.L., Truwit, C.L.: Investigation of Intraoperative Brain Deformation Using a 1.5 T Interventional MR System: Preliminary Results. IEEE Transactions on Medical Imaging 17(5), 817–826 (1998)CrossRefGoogle Scholar
  2. 2.
    Roberts, D.W., Hartov, A., Kennedy, F.E., Miga, M.I., Paulsen, K.D.: Intraoperative Brain Shift and Deformation: a Quantitative Analysis of Cortical Displacement in 28 Cases. Neurosurgery 43(4), 749–758 (1998)CrossRefGoogle Scholar
  3. 3.
    Buchholz, R.D., Yeh, D.D., Kessman, P.: The Correction of Stereotactic Inaccuracy Caused by Brain Shift Using an Intraoperative Ultrasound Device. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol. 1496, pp. 459–466. Springer, Heidelberg (1998)Google Scholar
  4. 4.
    Comeau, R.M., Sadikot, A.F., Fenster, A., Peters, T.M.: Intraoperative Ultrasound for Guidance and Tissue Shift Correction in Image-Guided Neurosurgery. Medical Physics 27(4), 787–800 (2000)CrossRefGoogle Scholar
  5. 5.
    Letteboer, M.M.J., Willems, P.W.A., Hellier, P., Niessen, W.J.: Acquisition of 3D Ultrasound Images During Neuronavigation. In: Lemke, H.U., Vannier, W.M., Inamura, K., Farman, A.G., Doi, K., Reiber, J.H.C. (eds.) Computer Assisted Radiology and Surgery, pp. 121–126. Springer, Paris (2002)Google Scholar
  6. 6.
    Rueckert, D., Sonoda, L.I., Hayes, C., Hill, D.L., Leach, M.O., Hawkes, D.J.: Nonrigid Registration Using Free-form Deformations: Application to Breast MR Images. IEEE Transaction on Medical Imaging 18(8), 712–721 (1999)CrossRefGoogle Scholar
  7. 7.
    Hellier, P., Barillot, C., Memin, E., Perez, P.: Hierarchical Estimation of a Dense Deformation Field for 3-D Robust Registration. IEEE Transactions on Medical Imaging 20(5), 388–402 (2001)CrossRefGoogle Scholar
  8. 8.
    Shekhar, R., Zagrodsky, V.: Mutual Information-based Rigid and Nonrigid Registration of Ultrasound Volumes. IEEE Transactions on Medical Imaging 21(1), 9–22 (2002)CrossRefGoogle Scholar
  9. 9.
    Meyer, C.R., Boes, J.L., Kim, B., Bland, P.H., Lecarpentier, G.L., Fowlkes, J.B., Roubidoux, M.A., Carson, P.L.: Semiautomatic registration of volumetric ultrasound scans. Ultrasound in Medicine and Biology 25(3), 339–347 (1999)CrossRefGoogle Scholar
  10. 10.
    Prager, R.W., Gee, A., Berman, L.: StradX: Real-Time Acquisition and Visualization of Freehand Three-Dimensional Ultrasound. Medical Image Analysis 3(2), 129–140 (1999)CrossRefGoogle Scholar
  11. 11.
    Letteboer, M.M.J., Viergever, M.A., Niessen, W.J.: Rigid registration of 3D ultrasound data of brain tumours. Computer Assisted Radiology and Surgery (2003) (in press)Google Scholar
  12. 12.
  13. 13.
    Letteboer, M.M.J., Niessen, W.J., Willems, P.W.A., Dam, E.B., Viergever, M.A.: Interactive Multi-Scale Watershed Segmentation of Tumors in MR Brain Images. In: Olabarriaga, S.D., Niessen, W.J., Gerritsen, F.A. (eds.) Proceeding of Interactive Medical Image Visualization and Analysis, pp. 11–16 (2001)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2003

Authors and Affiliations

  • Marloes M. J. Letteboer
    • 1
  • Peter W. A. Willems
    • 2
  • Max A. Viergever
    • 1
  • Wiro J. Niessen
    • 1
  1. 1.Image Sciences InstituteUniversity Medical CenterUtrechtThe Netherlands
  2. 2.Department of NeurosurgeryUniversity Medical CenterUtrechtThe Netherlands

Personalised recommendations