Helical CT Angiography of Aortic Stent Grafting: Comparison of Three-Dimensional Rendering Techniques

  • Zhonghua Sun
  • Huiru Zheng
Part of the Lecture Notes in Computer Science book series (LNCS, volume 3314)

Abstract

We aim to compare various 3D reconstruction techniques in the visualization of abdominal aortic aneurysms (AAA) treated with suprarenal stent grafts. 28 patients with AAA undergoing suprarenal fixation of aortic stent grafts were included in the study. Volumetric CT data were postprocessed with Analyze V 5.0 and four different 3D visualization methods were generated including shaded surface display (SSD), maximum intensity projection (MIP), volume rendering (VR) and virtual endoscopy (VE). Selection of CT threshold, time required for generation of 3D images as well as demonstration of 3D relationship between aortic stents and ostium were assessed in each method. Results showed that VR was found to be the most efficient 3D technique in the visualization of aortic stent grafts as well its relationship to the renal artery. VE was found to be particularly useful in demonstrating the encroachment of stent struts to the renal arteries.

Keywords

Renal Artery Abdominal Aortic Aneurysm Abdominal Aortic Aneurysm Maximum Intensity Projection Volume Rendering 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Government Statistical Service: Hospital episode statistics. 1. Finished Consultant Episodes By Diagnosis, Operation and Speciality. England: Financial Year 1992- 1993. HMSO, London (1995)Google Scholar
  2. 2.
    Lawrence, P.F., Gazak, C., Bhirangi, L., Jones, B., Bhirangi, K., Oderich, G., Treiman, G.: The Epidemiology Of Surgically Repaired Aneurysms In The United States. J. Vasc. Surg. 30, 632–640 (1999)CrossRefGoogle Scholar
  3. 3.
    Parodi, J.C., Palmaz, J.C., Barone, H.D.: Transfemoral Intraluminal Graft Implantation For Abdominal Aortic Aneurysms. Ann. Vasc. Surg. 5, 491–499 (1991)CrossRefGoogle Scholar
  4. 4.
    Parodi, J.C., Barone, A., Piraino, R., Schonholz, C.: Endovascular Treatment Of Abdominal Aortic Aneurysms: Lessons learned. J. Endovasc. Surg. 4, 102–110 (1997)CrossRefGoogle Scholar
  5. 5.
    Malina, M., Lindh, M., Ivancev, K., Frennby, B., Lindblad, B., Brunkwall, J.: The Effects Of Endovascular Aortic Stents Placed Across The Renal Arteries. Eur. J. Vasc. Endovasc Surg. 13, 207–213 (1997)CrossRefGoogle Scholar
  6. 6.
    Lau, L.L., Hakaim, A.G., Oldenburg, W.A., Neuhauser, B., McKinney, J.M., Paz- Fumagalli, R., Stockland, A.: Effect Of Suprarenal Versus Infrarenal Aortic Endograft Fixation On Renal Function And Renal Artery Patency: A Comparative Study With Intermediate Follow-up. J. Vasc. Surg. 37, 1162–1168 (2003)CrossRefGoogle Scholar
  7. 7.
    Broeders, I.A.M.J., Blankensteijn, J.D., Olree, M., Mali, W., Eikelboom, B.C.: Preoperative Sizing Of Grafts For Transfemoral Endovascular Aneurysm Management: A Prospective Comparative Study Of Spiral CT Angiography, Arterial Angiography And Conventional CT Imaging. J. Endovasc. Surg. 4, 252–261 (1997)CrossRefGoogle Scholar
  8. 8.
    Armerding, M.D., Rubin, G.D., Beaulieu, C.F., Slonim, S.M., Olcott, E.W., Samuels, S.L., Jorgensen, M.J., Semba, C.P., Jeffrey Jr., R.B., Dake, M.D.: Aortic Aneurysmal Disease: Assessment Of Stent-Grafted Treatment-CT Versus Conventional Angiography. Radiology 215, 138–146 (2000)Google Scholar
  9. 9.
    Sun, Z., Winder, J., Kelly, B., Ellis, P., Hirst, D.: CT Virtual Intravascular Endoscopy Of Abdominal Aortic Aneurysms Treated With Suprarenal Endovascular Stent Grafting. Abdom. Imaging. 28, 580–587 (2003)CrossRefGoogle Scholar
  10. 10.
    Zeman, R.K., Silverman, P.M., Vieco, P.T., Costello, P.: CT Angiography. A. J. Roentgenol. 165, 1079–1088 (1995)Google Scholar
  11. 11.
    Sun, Z., Winder, J., Kelly, B., Ellis, P., Kennedy, P., Hirst, D.: Diagnostic Value Of CT Virtual Intravascular Endoscopy In Aortic Stent Grafting. J. Endovasc. Ther. 11, 13–25 (2004)CrossRefGoogle Scholar
  12. 12.
    Choe, Y.H., Phyun, L.H., Han, B.K.: Biphasic And Discontinuous Injection Of Contrast Material For Thin-Section Helical CT Angiography Of The Whole Aorta And Iliac Arteries. Am. J. Roentgenol. 176, 454–456 (2001)Google Scholar
  13. 13.
    Bae, K.T., Tran, H.Q., Heiken, J.P.: Multiphasic Injection Method For Uniform Prolonged Vascular Enhancement At CT Angiography: Pharmacokinetic Analysis And Experimental Porcine Model. Radiology 216, 872–880 (2000)Google Scholar
  14. 14.
    Hu, H., He, H.D., Foley, W.D., Fox, S.H.: Four Multidetector-Row Helical CT: Image Quality And Volume Coverage Speed. Radiology 215, 55–62 (2000)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2004

Authors and Affiliations

  • Zhonghua Sun
    • 1
  • Huiru Zheng
    • 2
  1. 1.Faculty of Life and Health SciencesUniversity of UlsterNewtownabbeyNorthern Ireland
  2. 2.Faculty of EngineeringUniversity of Ulster at JordanstownNewtownabbeyNorthern Ireland

Personalised recommendations