Abstract

Intravenous therapy (IV therapy) refers to a treatment in which medication and nutrition is provided patients via a system that infuses these fluids directly into the patient’s bloodstream. Patients that are admitted to intensive care facilities, often require infusion of multiple fluids as physical systems fail to operate as intended. IV therapy administers drugs and nutrition into the patient’s bloodstream by connecting tubing, through which fluids can be transported, to the vein. The smallest fluctuations in dosages or drug administration delays have severe consequences for the new-born infants in the Neonatal Intensive Care unit. This study focuses on the development of an innovative IV set based on a new principle for merging various drugs and nutrition, called “Tulive”.

A user-centred approach was applied during the whole design process, including analysis of the complex healthcare context, literature study, observations & interviews with the different stakeholders and mainly its key user the ‘nursing staff’, contextual design models & methods, generative sessions and multiple user feedback sessions, etc.

Main themes that were uncovered include: product-user communication in terms of simplistic & unambiguous use cues, a sense of feedback regarding product related actions on multiple levels, user confidence to positively influence product interaction and inconveniences with fluid flow distinction.

Multiple design iterations have been performed where the needs, expectations and limitations of the user in context played a central role and motivated the design decisions made during the process. All these insights were translated and integrated in the final design proposal, “Tulive”. A name that relates to the aesthetic design, the tulip shape that aims to conceal the complexity and suggest operation in a user-friendly way.

The value of user-centered design lies in the increased product acceptance that can be achieved after new product implementation. In designing for healthcare, barriers that impede successful product acceptance can most often be attributed to the fact that majority of the medical products are not designed according to the needs, expectations and limitations of the medical professionals. Centralizing the intended user of the product during the design phases and allowing user input and contextual factors to shape the design in a systematic way will help evade these barriers and support product acceptance of any innovation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Auckland District Health Board Newborn Services Clinical Guideline. http://www.adhb.govt.nz/newborn/Guidelines/Nutrition/Nutrition.htm. Accessed 05 Mar 2015

  2. Beyer H, Holtzblatt K (1999) Contextual design: defining customer-centered systems. Elsevier Science & Technology, New York. Author, F., Author, S., Author, T.: Book title. 2nd edn. Publisher, Location (1999)

    Google Scholar 

  3. van Boeijen AGC, Daalhuizen JJ, Zijlstra JJ, van der Schoor RSA (2013) Delft design guide. BIS Publishers, Amsterdam

    Google Scholar 

Download references

Acknowledgment

The authors acknowledge the contribution of the Innofuse team comprised of Brechtje Riphagen, Luuk Evers, Pim Mijers, and master student Marijn Lardinois for the studies which were performed and as a proof of principle was delivered for the start of this project.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Armagan Albayrak .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Albayrak, A., Vreede, M., Evers, L., Goossens, R. (2019). The Role of Ergonomics in the Design of an Intravenous Therapy (IV) Set for Neonatal Intensive Care. In: Bagnara, S., Tartaglia, R., Albolino, S., Alexander, T., Fujita, Y. (eds) Proceedings of the 20th Congress of the International Ergonomics Association (IEA 2018). IEA 2018. Advances in Intelligent Systems and Computing, vol 818. Springer, Cham. https://doi.org/10.1007/978-3-319-96098-2_53

Download citation

Publish with us

Policies and ethics