Abstract

Fire safety law in Italy was updated on August 2015 with the introduction of the Internal Ministry Decree 3/8/2015. The regulation provides mandatory recommendations and guidance to consider the requirements of people with disabilities since the stages of design and to heed the inclusion as a prerequisite of the edifice. Disabilities is an umbrella term, covering impairments, activity limitations, and participation restrictions. An impairment is a problem in body function or structure; an activity limitation is a difficulty encountered by an individual in executing a task or action: while a participation restriction is a problem experienced by an individual in involvement in life situations. Disability can be permanent or temporary.

In the context of this new regulation, new and different means of access and egress consider the possibility to escape from a dangerous situation not only using stairs for egress, but also horizontal evacuation into another fire compartment at the same floor. These solutions are known as “area of refuge” and “progressive horizontal evacuation”.

Architectural solutions are synergically completed with other safety measures (e.g. fire alarm and detection systems, fire safety signs, escape lighting, etc.) to offer adequate performance to the needs of “all” the persons, including people with visual, mobility and cognitive impairments.

The contribution highlights some design solutions according to the Italian fire safety regulation, comparing them with the international ones, developed by each country using its own regulation.

Keywords

Inclusion Area of refuge Progressive horizontal evacuation 

References

  1. 1.
    Gershon MRR, Magda LA, Riley HEM, Sherman MF (2011) The world trade center evacuation study: factors associated with initiation and length of time for evacuation, Fire and MaterialsGoogle Scholar
  2. 2.
    World Health Organization (2001) International Classification of Functioning, Disability and Health (ICF). WHOGoogle Scholar
  3. 3.
    Bozzetti M (2003) Il nuovo ruolo del progettista della sicurezza. In: Proceedings of the workshop “workplaces: planning fire safety for everybody”, RomaGoogle Scholar
  4. 4.
    De Rocco P (1999) Dal concetto di “barriera architettonica” a quello di “accessibilità”. Progettare per la lentezza, PordenoneGoogle Scholar
  5. 5.
    D.M. (1989) Prescrizioni tecniche necessarie a garantire l’accessibilità, l’adattabilità e la visitabilità degli edifici privati e di edilizia residenziale pubblica sovvenzionata e agevolata, ai fini del superamento e dell’eliminazione delle barriere architettoniche, 14 June 1989Google Scholar
  6. 6.
    D.M. (1998) Criteri generali di sicurezza antincendio e per la gestione dell’emergenza nei luoghi di lavoro, 10 March 1998Google Scholar
  7. 7.
    Department of firefighters, public rescue and civil defense (2002) Circular n. 4 - Guidelines for assessing fire safety at workplaces where disabled people are presentGoogle Scholar
  8. 8.
    Department of firefighters, public rescue and civil defense (2004) Rescuing people with disabilities: emergency management guidelinesGoogle Scholar
  9. 9.
    Department of firefighters, Public Rescue and Civil Defense (2006) Circular Letter n. P/880 - Fire safety at workplaces where disabled people are present: fire safety check-listGoogle Scholar
  10. 10.
    D.M. (2015) Approvazione di norme tecniche di prevenzione incendi, ai sensi dell’articolo 15 del decreto legislativo 8 marzo 2006, n. 139, 3 August 2015Google Scholar
  11. 11.
    ISO/TR 16738 (2009) Fire-safety engineering - Technical information on methods for evaluating behaviour and movement of peopleGoogle Scholar
  12. 12.
    Villani T, Zanut S (2010) Sicurezza per le persone vulnerabili: approccio alla progettazione dei sistemi di comunicazione dell’allarme per bambini autistici. Autismo. Protezione sociale e architettura. Firenze: Alinea, pp 183–195Google Scholar
  13. 13.
    SFPE Task Group (2003) Engineering guide - Human Behaviour in FireGoogle Scholar
  14. 14.
    ISO 21542 (2011) Building construction – Accessibility and usability of the built environmentGoogle Scholar
  15. 15.
    ISO 7010 (2011) Graphical symbols - Safety colours and safety signs - Registered safety signsGoogle Scholar
  16. 16.
    Ozel F (1993) How Cognitive Factors Influence Wayfinding. NFPA J, May/JuneGoogle Scholar
  17. 17.
    Romano G (2016) La tutela delle strutture strategiche in emergenza: l’esperienza Italiana. In: Emergenza e Fragilità 2015, Il progetto degli edifici strategici a partire dall’emergenza: ospedali e strutture sanitarie. Antincendio, 1, pp 91–94Google Scholar
  18. 18.
    Marsella S, Zanut S (2009) Fire safety of people with disabilities: the structure of regulation in Italy. In: International conference on accessibility and safety for all, pp 175–186. Thessaloniki GRGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  1. 1.Italian National Fire Fighters CorpsRomeItaly
  2. 2.RomeItaly

Personalised recommendations